Telular TELGUARD DIGITAL TG-1 Installation And Operating Instructions Manual Download Page 14

56034002  1/9/2006 

7

                            

 

© 2006 Telular Corporation

 

5.0 INSTALLATION 

STEPS 

This five-step installation approach (5.1 through 5.5) provides the alarm installer with the easiest and fastest 
method of properly installing Telguard.  Please follow the instructions carefully and if you should need 
assistance or have any questions, call Telular TECHNICAL SUPPORT at 1-800-229-2326 extension 9. 
 

NOTE: Dealer Account Establishment and Cellular Activation must be complete prior to Installation 
(see section 3.0) 

 

 

5.1   S

TEP 

1: A

CTIVATE 

& R

EGISTER THE 

T

ELGUARD UNIT

 

Installation Tip: Activate cellular service prior to leaving for the job site to avoid a second trip.  

 

  

5.1.1  Activate Cellular Service 

Complete the activation form online at 

www.Telguard.com

 or Fax the activation form that is included 

with the product to Telular Cellular Service to activate cellular service. Service activation takes place 
Monday-Friday from 8:00AM to 8:00PM and Saturday 9:00AM to 1:00PM EST.  Service activation 
occurs within 30 minutes of receipt of the activation form. Registration occurs automatically upon 
power up of the unit.  

5.1.2 Locate 

Unit 

 

Pick a spot next to the C/C where you think the Telguard will be mounted and place the unit down 
temporarily in that spot.  

Do not mount it permanently now

, since it may need to be moved to 

receive a better cellular radio signal or a remote high-gain antenna may be necessary. 

 

5.1.3  Connect Backup Battery and AC Power Transformer 

 

To apply power to Telguard, attach battery leads to battery terminals noting polarity.    
 

 

  

Connect the Telguard AC power transformer (see A3.2 for acceptable UL Listed transformers) to AC 
terminals using stranded copper insulated wire following wire gauge and length recommendations below:  
 
 Recommended 

Wire 

Size 

Length Not to Exceed 

  

18 

ga 

 

20 

ft 

  

16 

ga 

 

40 

ft 

  

14 

ga 

 

60 

ft 

 

5.1.4  Connect Antenna and Temporarily Place Unit   

The Telguard is supplied with an antenna. In most cases the antenna may be mounted directly to the 
Telguard. If a stronger radio signal is required, the antenna must be moved to a better signal location 
using a Telular antenna cable and bracket accessory (sold separately).  The characteristics of the 
Telguard antenna can be altered depending upon the wall material and materials contained within the 
wall chosen for mounting.  These effects may not be clearly identified by RSSI monitoring alone.  The 
wall materials may have a more profound affect on the antennas transmit band performance.  
 
When selecting a mounting location, do not mount this unit in an area where the general public could 
reasonably be within 20cm (8 inches) of the antenna. The supplied dipole antenna is for INDOOR 
USE ONLY. 
 

Note 1:

 Optimum RF performance can usually be found at the highest point within a building with the 

fewest number of walls between the Telguard’s antenna and the outside of the premises. 

Note 2

: To avoid interference with other electronic devices operating in the area, avoid mounting the 

Telguard’s antenna near other electronic devices.  

Note 3

: The Telguard Digital TG-1 unit with supplied dipole antenna is designed for indoor installations.    

Summary of Contents for TELGUARD DIGITAL TG-1

Page 1: ...ENTIAL For use by TELGUARD customers only Distribution to others strictly prohibited Revised January 9 2006 TELGUARD is a registered trademark of Telular Corporation Products are protected under one o...

Page 2: ...ard model TG1G0001 is UL Listed for Household Fire systems and Household Burglary systems This means that the TG1G0001 may be used in Household Burglary systems Household Fire systems or combined Hous...

Page 3: ...ectronics Engineers IEEE and in 1992 the American National Standards Institute ANSI updated the 1982 ANSI Standard for safety levels with respect to human exposure to RF energy Over 120 scientists eng...

Page 4: ...en in any area with a potentially explosive atmosphere It is rare but your Telguard Digital or its accessories could generate sparks Sparks in such areas could cause an explosion or fire resulting in...

Page 5: ...UND You agree to accept sole responsibility for any misuse of the Product by you and in addition any negligent or illegal act or omission of your or your agents contractors servants employees or other...

Page 6: ...ILURE CONDITION RFC 2 2 4 COMPLETE POWER SUPERVISION 2 2 4 1 LOW MISSING BATTERY CONDITION LBC 2 2 4 2 AC FAILURE CONDITION ACFC 2 2 4 3 DIAL TONE FAILURE DTF 2 2 4 4 CATASTROPHIC FAILURE CF 2 2 5 TEL...

Page 7: ...NAL TRANSMISSIONS OVER CELLULAR 10 5 4 STEP 4 CONNECT SUPERVISORY TRIP OUTPUTS 10 5 4 1 DECIDE ON A STC TRIP OUTPUT STRATEGY 11 5 4 2 CHECK TELGUARD SUPERVISORY TRIP TO C C 11 5 4 2 1 REPROGRAM C C TO...

Page 8: ...uard has its own internal power supply battery charger All cellular monitoring and supervisory functions are built in No extra modules are required The Listed equipment at the Telular Communication Ce...

Page 9: ...the STC trip output restores after 60 seconds 2 4 3 Dial Tone Failure DTF The Telguard continuously monitors the 30V sully circuit that provides dial tone to the C C A Dial Tone Failure DTF is declar...

Page 10: ...e battery and AC power The terminal strip can accommodate solid or stranded wire sizes from 14 to 22 gauge 2 6 1 Programmable Supervisory Trip Output STC Relay The Telguard Digital TG 1 has one superv...

Page 11: ...transmit signals over cellular LED 4 Acknowledgement Solid On Telguard TG 1 waiting for acknowledgement from Communication Center Off Idle state Red Flashing When flashing with LED 1 unit has failed...

Page 12: ...he customer account unit location and system test plan information 3 1 DEALER ACCOUNT ESTABLISHMENT Prior to activation of any Telguard unit a Dealer Account must be established Once the Dealer Accoun...

Page 13: ...ating under 3 Confirmation from the Telular Communications Center that the Telguard Digital unit is ready for installation and registration Registration is the process of establishing communications f...

Page 14: ...apply power to Telguard attach battery leads to battery terminals noting polarity Connect the Telguard AC power transformer see A3 2 for acceptable UL Listed transformers to AC terminals using strand...

Page 15: ...on LED 3 2 off 100 dBm 2 LED 5 4 on LED 3 slow flash LED 2 off 90 dBm Minimum signal strength required 3 LED 5 3 on LED 2 off 80 dBm 3 LED 5 3 on LED 2 slow flash 70 dBm 4 LED 5 2 on 60 dBm Note LED 1...

Page 16: ...NG 2 FLASH LBC LOW BATTERY AND OR BATTERY CHARGER FAIL 3 FLASH N A 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH DTF DIAL TONE FAIL 5 3 1 Setup Programming the Operating Parameters in the T...

Page 17: ...899 will return unit to factory default settings 5 3 3 Verify Alarm Signal Transmissions over Cellular Trip several alarms on the C C and verify that the central station received them by calling the...

Page 18: ...s missing Check to see that the C C transmits the STC trouble code over cellular to the central station Reconnect the battery and check during the next 60 seconds to see that the STC LED goes off indi...

Page 19: ...OUBLE STC See Table LED 1 GREEN REGISTRATION See Table SYSTEM TROUBLE STC LED 2 1 FLASH AC LOW MISSING 2 FLASH LBC LOW BATTERY 3 FLASH Not Used 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH...

Page 20: ...grammed supervisory trouble code AC Power Fail ACFC AC failure detected at 102 VAC Low Missing Battery Condition LBC due to Low Battery detected at 11 6 VDC Radio Communications Failure RFC due to Fai...

Page 21: ...or TG 1 LED 3 MODE Yellow Fast Flash C C off hook to transmit signals over cellular LED 4 Acknowledgement Solid ON Telguard TG 1 waiting for acknowledgement from Communication Center OFF Idle state Re...

Page 22: ...turn unit for repair on RMA Not Active for Cellular alarm Transmission Yes LED 5 off Yes None Telguard will not function until operating parameters are downloaded to the Telular Communication Center S...

Page 23: ...56034002 1 9 2006 16 2006 Telular Corporation A2 1 ACTIVATION FORM...

Page 24: ...ber S189480032 GlobTek part number WA1E800J00 N GTGTAB A3 3 DIGITAL CELLULAR RADIO The Telguard TG 1 radio supports GSM GPRS cellular protocol It is equipped with an integrated radio transceiver confo...

Page 25: ...e antenna TG1G0001 is UL Listed for the following o UL Household Burglary o UL Household Fire o UL Household Burg Fire Combination General Accessories ACD 12 12 feet of antenna cable and mounting brac...