TLS-3B User’s Manual
40-400-00032, Rev. B
17
SUMMARY OF PROGRAMMING COMMANDS
System Commands
Command Name
Command
Notes
Programming Mode
Setup 1
Setup 2
**
99##
**
98##
Reset to Factory Defaults
*
00#0#
*
00#0#
Tone Following Disconnect
*
04#X#
Dial Tone (default) X=0
Busy Signal X=1
Reorder Signal X=2
Silence X=3
Forced Disconnect Duration
(COD)
*
05#time#
Range = 0 to 100 in 50 mS steps
(100 = 5 seconds).
850 mS (default), i.e.
*
05#17#.
Cutoff on Disconnect Delay
*
06#time#
Range = 11 to 200 in 100 ms steps.
Factory default is 2 seconds, i.e. *06#20#.
Ringing Frequency
*
07#X#
20 Hz X = 0 (default)
25 Hz X = 1
Hook-flash Detect
*
10#X#
Disable X = 0 (default)
Enable X = 1
Line Attenuation
*
09#X#
X = 0 attenuation = -6 dB (default)
X = 1 attenuation = -16 dB
Test Numbers
Dial Tone
Busy Signal
Reorder Tone
Ringback Tone
Silence
*60#number#
*61#number#
*62#number#
*63#number#
*64#number#
Valid digits are 0-9.
Default = 83781 (Test 1)
Default = 83782 (Test 2)
Default = 83783 (Test 3)
Default = 83784 (Test 4)
Default = 83785 (Test 5)