ISDN Demonstrator User’s Manual
40-400-00011, Rev. B
13
General Operation
Provisioning of features using the ISDN Demonstrator configuration software
allow the user to select from several stored configurations, as well as allow
the user to store other configurations as needed. If a stored configuration is
selected, and any feature is changed, the Configuration Name changes to
(Untitled). If you attempt to exit the program without saving the configuration,
you will be prompted to do so.
Defaults
To configure default provisioning, based on the selected Switch Type:
QUICK METHOD -
During initial power on, move the power switch to the
RESTART and hold for 1 second.
OR,
STEP 1
Run the Windows based configuration software.
STEP 2
Select the SWITCH TYPE
STEP 3
Select DEFAULTS .
STEP 4
Remove all communications devices from the Simulator and
press the DOWNLOAD button. An automatic RESTART is
issued as part of the
DOWNLOAD.
Important: When the Simulator configuration is changed using the
Windows based configuration software, always reinitialize any
connected devices.
Switch Type
The Simulator is configured at the factory for National ISDN-1 protocol. To
simulate the AT&T 5ESS Custom configuration or other future protocols, you
must change the Simulator’s Switch Type.
Switch Type
Emulation
National ISDN-1
NI-1
AT&T Custom
AT&T Custom
STEP 1
Run the Windows based configuration software.
STEP 2
Select the Switch Type.
STEP 3
Select DEFAULTS (if you want the default settings for the selected
switch)
STEP 3
Remove all communications devices from the Simulator and select
the DOWNLOAD button. An automatic RESTART is issued as part of the
DOWNLOAD.
STEP 4
Reconnect all communications devices.