Flame-out protection device working principle as follow:
Flame- out protection working principle Flame-out protection device working principle, for gas product: press
down the knob to have gas access and then ignite the burner. Thermocouple got heated up by the flame,
and it creates thermoelectric potential, thermoelectric potential induce into electromagnetic coil through
the wire, it creates magnetic field which makes electromagnetic valve operate, gas valve is enabled, firing
aisle is open. Remain normal combustion, when it encounters strong wind or soup overflow, and the flame
went off , thermoelectric potential will go down to zero in a very short time, electromagnetic coil loss power,
so electromagnetic valve stop working , it will be reset under the action of the spring, valve will cut off the gas
access , cut off gas supply, ensure safety .
Troubleshooting:
PROBLEM
POSSIBLE CAUSE
SOLUTION
Gas Smell
Connection hose or tubing puncture
Change the installation
Burners incorrect position
Place them in the correct
position.
An oven burner in use accidentallywent
off
Call the costumer service
Pressure regulator badly installed
Install it correctly
Strong Smells
Oil and grease used to manufacture you
stove
It is normal the first time you use
it.
Noise
Metal expansion due to heat
Normal
Electric components to
not function
Disconnected stove socket without power Connect the electric cord Check
the socket connecting a lamp.
When turning on the
lamp,the roasting rod
It is normal.