background image

   18 Goodyear, 

Irvine, CA  92618

[email protected]
www.telluspower.com

UP80J Networked EV Charging Head Unit

Installation Manual  (20140501)

The UP80J  is an electric vehicle charging head designed for installation into GRIDbot 
standard UP housings. 

                 

C                         US

Made

USA

in the

KIT301-IM-20140501

Summary of Contents for UP80J

Page 1: ...wer com www telluspower com UP80J Networked EV Charging Head Unit Installation Manual 20140501 The UP80J is an electric vehicle charging head designed for installation into GRIDbot standard UP housing...

Page 2: ...FY This GRIDbot station should not be modified in any way This will void the warranty compromise protection and could result in a possible shock or fire hazard OPERATING CAUTIONS Ensure that the charg...

Page 3: ...pe buttons LED status indicators RGB led with auto brightness adjust for ambient light Safety devices Ground fault detection 20mA Charge Circuit Interrupt Device CCID20 including 3 auto retry 15 minut...

Page 4: ...e needed Short driver handle for standard bits Right angle driver ratchet for standard bits Set of SAE wrenches Hole cutting drill bits to match conduit size Spirit Level Smart phone GPS coordinate co...

Page 5: ...Breaker Panel UP80J Station 40A G L1 L2 240V Level 2 L1 L2 UP80J Station G 240V Level 2 L1 L2 UP80J Station G 240V Level 2 N N Size conduit to carry five 5 wires 4 30 Amp continuous load rated conduct...

Page 6: ...h station housing then run data conduit between each Size data conduit to carry up to 2 Cat5e cables each Pull Cat5 data cable in accordance with the number of station at the site Leave 6ft of cable e...

Page 7: ...ed to the base plate by inserting it through the lock washer and into the back of the plate Thread the hardware set into base plate until it is finger tight Now tighten the locking nut down onto the b...

Page 8: ...ent Store the box in a dry place If repacking is required First place the station head the anti static bag Secure neck of bag with tie Roll cable up in to an 15 diameter coil Leave a 6 between cable c...

Page 9: ...ing and unravel the charg ing cable s Thread the level 2 coupler s downwards though the black rubber strain relief loop near the base of the station housing post Pull most of the cable s through Loose...

Page 10: ...First connect the green equipment grounding conductor to the grounding bar on the station head unit NOTE The station will not operate without a successful ground path to the service panel Insert one...

Page 11: ...5 7 8 on the modular jack at each end orange white orange green white blue blue white green brown white brown Test each segment of terminated cable with a simple battery operated Ethernet tester aprox...

Page 12: ...IDkey again to confirm the number on the screen matches the ID on the station housing Write the Station ID for each station at the site on the from provided on page 13 Then push the blue back button I...

Page 13: ...Station ID Qty L 1 Ports Qty L 2 Ports GPS 888 88888888 888 88888888 Station ID Qty L 1 Ports Qty L 2 Ports GPS 888 88888888 888 88888888 Station ID Qty L 1 Ports Qty L 2 Ports GPS 888 88888888 888 8...