![TellCard Systems EMR KB/KU-AP Programming Manual Download Page 25](http://html1.mh-extra.com/html/tellcard-systems/emr-kb-ku-ap/emr-kb-ku-ap_programming-manual_1083958025.webp)
25
Service Station (Passage Toggle) – Mode 2
In Service Station (Passage Toggle) - Mode 2, the lock is unlocked until the room is occupied,
and the thumbturn is engaged. When the thumbturn is engaged, all users except the master
are disabled. Entering a valid credential secures the room until another valid credential is
entered to unlock the room.
1. Enter master code, followed by #.
2. Press 2.
3. Press *.
Key Stroke Example
Service Station
(Passage Toggle)
– Mode 2
1. Key in master code.
2. Press #.
3. Press 2.
4. Press *.
Service Station (Passage Toggle) Mode Timer
The Service Station (Passage Toggle) Mode Timer automatically locks after a configurable
number of hours (Service Station (Passage Toggle) – Mode 2). A setting of zero (0) disables
this feature. The default setting is disabled (0); minimum time is 1 hour, maximum is 9 hours.
Key Stroke Example
Service Station
(Passage
Toggle )
Mode Timer
Default = 0
X = Time Choice
(Hours)
1. Key in master code.
2. Press #.
3. Press 3.
3. Press #.
4. Press X
(Time Choice).
5. Press *.
Unlock Delay Time
The Unlock Delay Time function sets the number of seconds the lock remains unlocked
when in Relock – Mode 1. The default time is 4 seconds; minimum is 1 second, maximum is
99 seconds.
Key Stroke Example
Unlock
Delay Time
Default =
4 seconds
X = Time Choice
(Seconds)
1. Key in master code.
2. Press #.
3. Press 4.
4. Press #.
5. Press X
(Time Choice).
6. Press *.
E
M
R
K
B
/K
U
P
R
C
o
n
fi
g
u
re
L
o
c
k
F
u
n
c
ti
o
n
s
(C
o
n
t’
d
)
E
M
R
K
B
/K
U
P
R
C
o
n
fi
g
u
re
S
e
tt
in
g
s
2
1
3
4
2
#
*
2
1
3
4
3
#
*
#
X
2
1
3
4
4
#
*
#
X