![tell ecoLINE SIA Installation And Application Manual Download Page 6](http://html1.mh-extra.com/html/tell/ecoline-sia/ecoline-sia_installation-and-application-manual_1083860006.webp)
6
3.1.6 Modification of the settings by SMS
A superuser phone number can be configured in this section, which is authorized to
modify the settings by sending commands by SMS. Details about the SMS commands
can be found in the
chapter.
3.1.7 Incoming SMS message forwarding
The module forwards the incoming SMS messages to the phone number entered here.
This is useful for receiving SIM card balance information messages sent by the GSM
service provid
er to the module’s SIM card, etc. (if left blank, the module will automatically
delete all incoming SMS messages).
Attention! DO NOT enter here the phone number of the SIM card inserted into the
module!
3.2 Configuring by SMS commands
It is possible to configure the module and receive status information by sending the
appropriate command in SMS to the module’s phone number. First please set the
SUPERUSER phone number from which the module will then accept SMS commands:
SMS command
Operation
SUPERUSER#
The mod
ule sets the sender’s phone number as
Superuser.
The module accepts this command only if
no Superuser has been set yet!
SU=#
Deletes the current Superuser phone number. The module
accepts this command only from previously set (actual)
Superuser phone number.
APN=
APN name
#
Sets the APN name
UN=
APN
user name
#
Sets the APN user name
PW=
APN
password
#
Sets the APN password
PH
X
=
dialed number
#
Setting the numbers dialed by the alarm control panel
assigned to IP addresses:
substitute "X" with the ordinal number of the number dialed
by the alarm control panel to be set or modified (1 to 4).
IP
X
=
IP address
#
Setting the IP addresses:
substitute "X" with the ordinal number of the IP address to
be set or modified, which you wish to assign to the number
dialed by the alarm control panel, with the same ordinal
number (1 to 4).
PORT
X
=
port number
#
Setting the port numbers:
substitute "X" with the ordinal number of the IP address
port number to be set or modified (1 to 4).
TEST
X
=
Y
#
Setting the supervision test report assigned to IP
addresses: substitute
„X” and „Y” with the desired values:
X= the ordinal number of the IP address
Y=0 (test report sending disabled)
Y=1 (test report sending enabled)