7 Technical details
7.1 Technical specification
Supply voltage:
9-30 VDC
Nominal current consumption:
110mA @ 12VDC, 60mA @ 24VDC
Maximum current consumption:
400mA @ 12VDC, 200mA @ 24VDC
Operating temperature:
-
20ºC - +70ºC
Transmission frequency:
GSM 900/1800 MHz, 850/1900 MHz
GSM phone type:
Simcom SIM900
Dimensions:
100 x 70 x 19mm
Weight:
80g (packed: 100g)
7.2 Generated phone line specification
Line voltage:
48 V
Line current:
20 mA
Line impedance:
600 Ohm
Ring voltage:
±72V (25 Hz)
Tone:
400 Hz
7.3 Contents of the package
ecoLINE SIA IP module
GSM 900/1800 MHz antenna (0dB)
Velcro fastener
Installation and application manual
Warranty card