Control mode 2:
- For one or two gates, or one gate with two opening options (partial/ total
opening).
- Both outputs are normally open (NO).
- Both outputs are controlled by call with caller identification as configured
(OUT1 only, OUT2 only, or both at the same time).
- Output control permission can be configured separately for each user and
each output.
- A control call only opens the gate. Closing should be done automatically by
the gate automation control board.
Control mode 3:
- For single-gate automations
that
require
triggers
for
opening and closing on the
same input.
- Opening and then closing by
a single call.
- Output OUT1 is normally open
(NO), while OUT2 is normally
closed (NC).
- Output OUT1 is used to
control the gate, while OUT2
is used to interrupt the
photocell
sensor
circuit,
thereby providing an option to
keep the gate open for the
configured period of time.
- Keeping the gate open permanently on a second call.