ME310G1 Hardware Design Guide
1VV0301588 Rev. 12
Page 18 of 96
2021-06-14
Band
REFsens (dBm)
Typical
REFsens (dBm)*
3GPP Limit
CAT M1 / Band85
-104.0
-
CAT NB2 / Band1
-115.7
-108.2
CAT NB2 / Band2
-115.9
-108.2
CAT NB2 / Band3
-115.5
-108.2
CAT NB2 / Band4
-115.1
-
CAT NB2 / Band5
-115.8
-108.2
CAT NB2 / Band8
-115.3
-108.2
CAT NB2 / Band12
-115.5
-108.2
CAT NB2 / Band13
-115.5
-108.2
CAT NB2 / Band18
-115.8
-108.2
CAT NB2 / Band19
-115.6
-108.2
CAT NB2 / Band20
-114.7
-108.2
CAT NB2 / Band25
-115.9
-
CAT NB2 / Band26
-115.7
-108.2
CAT NB2 / Band28
-115.5
-108.2
CAT NB2 / Band66
-115.2
-108.2
CAT NB2 / Band71
-107.5
-
CAT NB2 / Band85
-115.5
-
Table 10: RX Sensitivity ME310G1-WW * 3GPP TS 36.521-1 Release 15 Minimum performance
requirement
ME310G1-W2
Band
REFsens (dBm)
Typical
REFsens (dBm)*
3GPP Limit
CATM1 / Band1
-106.6
-102.7
CAT M1 / Band3
-107.0
-99.3
CAT M1 / Band8
-106.9
-99.8
CAT M1 / Band20
-106.8
-99.8
CAT M1 / Band28
-107.4
-100.8
CAT M1 / Band31
-105.2
-96.6