29

D4130145B

Summary of Contents for iIS-010

Page 1: ...uration 4 4 Name and Function of Parts 6 5 Specification 9 6 External View 22 Restriction For Use 26 Precautions 27 Exemption Clauses 27 The contents of this product specification may be revised without notice to reflect future product modifications Please confirm the functions and the specifications on the latest specification sheet Total 29 pages D4130145B ...

Page 2: ... for part type job code part inspection part decision and light control 4 Standard interfaces Standard serial and Ethernet 10 100baseT communication interfaces for configuration and data reporting 5 Graphical user interface Intuitive step by step configuration and monitoring GUI accessible through a standard Microsoft browser page and available in two languages English and Japanese 6 Local Scaling...

Page 3: ...gths Annuli thread spacing wave tool multiple measures of length and spacing of parts such as pins on an electrical connector rake tools and other part measures 9 Label Application User defined features including label rotation movement rejection thresholds enables you to define your label quality criteria All settings are quickly defined and changed using a sliding bar from lower to higher Automa...

Page 4: ...mera cable Direct Fixing 2m 1 Cable fixing direction viewed from rear Right Control Unit iIS 010 series compatible 1 Accessories Ethernet crossover cable KB 10T5 03CK Sanwa supply 3m 1 DIN rail mounting kit CKD 80 Takachi Denki 2 Screws for the mounting kit PB3X10BS NI 4 Plug for power cable 39860 1002 MOLEX 2 terminal type 1 Plug for parallel I O cable 1 1546208 5 AMP Buchanan 15 pin type 1 Flopp...

Page 5: ...l including in the floppy disk Others ActiveX control libraries Auto download from the control unit Microsoft Windows Microsoft Internet Explorer and ActiveX are registered trademarks of Microsoft Corporation U S in the U S and other countries Optional Accessories Camera Lens For iIS 010 Dedicated lenses M10 5 P0 5 female For iIS 011 Dedicated lenses M15 5 P0 5 male For iIS 012 C mount lenses Came...

Page 6: ...o the control unit for local display of the camera image 3 RS 232C connector Connect with PC or PLC by using the crossover RS 232C cable 4 Power connector Connect the DC Power Supply 24V DC 10 to the control unit power connector 5 LED indicator POWER power on indicator steady green LED1 server heartbeat slow flashing green LED2 acquisition frame done or processing start rapid flashing green LED3 r...

Page 7: ...te an interrupt to the CPU informing it that a line changeover is taking place The system will then load one of 16 predefined solutions according to the BCD code present on the job selection inputs During this process the ready signal will go OFF indicating a busy state D TRIG 1 decision trigger input representing detection of a valid part to make a decision on Decisions are queued following every...

Page 8: ...iIS 010 series product specification Ver B Oct 12 2004 9 Figure 2 Control unit top view 9 Mounting kits for DIN rail You can mount with 32mm 35mm width type DIN rail 8 D4130145B ...

Page 9: ...as guaranteed in the conditions combined with the peripheral devices of the 3rd clause When used combining parts other than specification of our company I ask you to have final EMC conformity checked of a visitor with a machine and the whole equipment Camera head specification Image sensor All Pixel s Data Read out Interline CCD Total pixels 692 H 504 V Valid pixels 648 H 494 V Unit cell size 7 4 ...

Page 10: ...e Sensor Trigger mode Selectable Internal Timer or External trigger Exposure time Settable from 1 to 1024 1 step Approx 60µs Brightness Approx 3 19 LSB 8 bit Contrast Approx 4dB Processor 266MHz Intel compatible SOC processor Memory 64MB image acquisition and processing 32MB program and solution job storage Device Name NS2 Default IP address 192 168 0 100 Default Subnet Mask 255 255 0 0 Default MA...

Page 11: ...CP IP LED indicator Orange indicates for working on 100BaseT Green indicates for working on 10BaseT Light on indicates for linking Ethernet Blink indicates for working communication Cables Twisted Pair Category 5e or greater Maximum cable length 100m Unshielded Twisted Pair cable DISPLAY 1ch Connector D SUB 15 pin Right Angle female Table 3 Local Display connector pin assignment Pin Terminal Funct...

Page 12: ... I O Description 1 NC 6 NC 2 I RX Receive Data 7 NC 3 O TX Transmit Data 8 NC 4 NC 9 NC 5 Ground Control type RS 232C Non procedure Bit rate 110 300 600 1200 2400 4800 9600 19200 38400 57600 115200 bps 230400 460800 921600 bps are not supported Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity Odd Even None Mark Space Flow Control None Parallel I O 8 inputs COM0 GPI0 3 SEL D TRIG TRIG 7 outputs COM1 GPO0...

Page 13: ...igger input SEL Change Solution input Polarity Positive Minimum pulse width 200µs Select Solution Inputs 4ch Table 5 Select Solution Inputs GPI3 GPI2 GPI1 GPI0 ID_00 OFF OFF OFF OFF ID_01 OFF OFF OFF ON ID_02 OFF OFF ON OFF ID_03 OFF OFF ON ON ID_04 OFF ON OFF OFF ID_05 OFF ON OFF ON ID_06 OFF ON ON OFF ID_07 OFF ON ON ON ID_08 ON OFF OFF OFF ID_09 ON OFF OFF ON ID_10 ON OFF ON OFF ID_11 ON OFF ON...

Page 14: ...itter to Collector Total Power Dissipation 120mW Load voltage range 5V to 24V Rated output current 50mA Decision outputs 4ch GPO0 Pass output GPO1 RESERVE GPO2 Recycle output GPO3 Reject output Light control output STR 1ch READY output RDY 1ch OFF Booting the control unit When changing solution ON After boot start application After changing solution External Dimensions 150 W 60 H 80 D Weight Appro...

Page 15: ...System Microsoft Windows NT 4 0 SP5 or later Microsoft Windows 2000 SP3 or later Microsoft Windows XP SP1 Web Browser Microsoft Internet Explorer 6 0 or later ActiveX control supported History Log Viewer Hilgraeve HyperTerminal for Conditional strings output Microsoft EXCEL for the History log of CSV type PC type X86 compatible Interface Ethernet Static or Dynamic addressing RJ 45 type connector T...

Page 16: ...lt Measured Value V N 2 1 Measured Value V N 2 2 Inspection Number Parts Inspection Number Time Stamp Inspection time taken from Client PC HH MM SS Result Pass Recycle Fail Measured value The values for each measurement Measurements sort in ascii order Significant digit 3 Table 7 CSV file output format Label application A B C D E 1 Inspection Number N Time Stamp T1 Failed Area FN Angle Offset AN R...

Page 17: ...ctable Internal Trigger or External Trigger Internal Trigger period Settable from 35ms to 1000ms 1 step 1ms Inspection Trigger Delay Settable from 0ms to 1500ms 1 step 1ms Light Control Duration Settable from 0ms to 64ms 1 step 1 ms Offset Settable from 0µs to 2000µs 1 step 1µs Local display refresh rate Every 100 Continuous None Exposure Selectable from 1 to 1024 1 step 60 0µs Brightness 0 100 Co...

Page 18: ...n the product line via Ethernet is NOT guaranteed Inspection status Selectable Ready to Run Running Monitoring Statistics Information Displaying parts inspected number Displaying parts skipped number Displaying Pass Recycle Reject parts number Inspection Information Displaying set upped inspection information Processing Time Displaying the total time take to find search and inspect the part Reset ...

Page 19: ...ine a point or measure the diameter or circularity of a circle Circle Circle measure the distance between 2 circle centers Circle Line measure the distance from a circle center to an edge Point Circle measure the distance between a circle and one point Concentric Circles measure the distance from each circle center to the average center Ruler Properties Naming measurement Setting Tolerance settabl...

Page 20: ...x Std Dev measure pixel intensities in a ROI and calculate statistics Statistics Properties Naming measurement Setting Tolerance Track locator Enable Disable Eraser delete a measurement Tip Window gives hints on drawing measurements Color settings changing colors of the measurement tools and graphics to suit your preference HighLight1 Actual Edge User Drawn User Drawn Same Tool Gauge Point Constru...

Page 21: ...l Locator On Off Label Rotation Tolerance Settable 5 Maximum 1step 0 25 Acceptable Tolerance Contrast Failed area Learning Good Parts Acceptable Tolerance Differences Forgetting Learned Images Monitoring Inspections Statistics Information Displaying parts inspected number Displaying parts skipped number Displaying Pass Recycle Reject parts number Processing Time Displaying the total time take to f...

Page 22: ...iIS 010 series product specification Ver B Oct 12 2004 6 External View iIS 010 series control unit external view 22 D4130145B ...

Page 23: ...iIS 010 series product specification Ver B Oct 12 2004 iIS 010 20mm square camera head external view 23 D4130145B ...

Page 24: ...iIS 010 series product specification Ver B Oct 12 2004 iIS 011 φ17mm camera head external view 24 D4130145B ...

Page 25: ...iIS 010 series product specification Ver B Oct 12 2004 iIS 012 C mount camera head external view 25 D4130145B ...

Page 26: ...tions against electromagnetic wave interference if the camera is used with a servomotor inverter or other electromagnetic wave generating equipment This product is not designed or manufactured to be used for control of equipment directly concerned with human life 1 or equipment relating to maintenance of public services functions involving factors of safety 2 Therefore the product shall not be use...

Page 27: ...e unreliably In these cases the purchaser may be required to bear the cost of any repairs For information on hardware compatibility please contact TELI or a TELI dealer or distributor Exemption Clauses TELI assumes no responsibility or liability for damage arising from fire earthquake an act by a third party or other accidents or intentional or careless error or misuse by the user or use under abn...

Page 28: ...plication facility or equipment that requires extreme reliability TELI assumes no responsibility or liability for injury fire or consequential damages arising from failure of the CCD camera in such applications Expenses we bear on this product shall be limited to the individual price of the product 28 D4130145B ...

Page 29: ...7 1 4 chome Asahigaoka Hino shi Tokyo 191 0065 Japan Overseas Sales Department Phone 81 42 589 8771 Fax 81 42 589 8774 URL http www toshiba teli co jp iIS 010 series Product Specification October 2004 29 D4130145B ...