24 HOUR ZONE (N.C.)
TELCO DIALER
ANTENNA
T
R
1 2 3 4 5 6 7
TELGUARD
Digital TG-1
OPEN = NORMAL
SIGNAL
STRENGTH
LEDS
www.Telguard.com
REFER TO INSTALLATION AND OPERATING
INSTRUCTIONS MANUAL. THIS DEVICE COMPLIES
WITH FCC RULE PART 15.
TELULAR CORPORATION
420 Thornton Road, Suite 109
Lithia Springs, GA 30122
(800) 229-2326 Fax: 678-945-1651
8 9
+
_
JP4
J7
SIM
J10
SHORTED = RSSI
HOST C/C
1
2
3
4
5
SYSTEM STATUS LEDS
NORMAL MODE
LED #5 GREEN
ON = RADIO INITIALIZING
FLASH = COMMUNICATING
LED #4 RED
ON = WAITING FOR RESPONSE
If flashing with LED 1 = DENIED
(NACK)
LED #3 YELLOW
OFF = MODE 2 (CELL Primary)
FLASH = C/C OFF HOOK CELL
LED #2 RED
SYSTEM TROUBLE, STC
(See Table)
LED #1 GREEN
REGISTRATION (See Table)
SYSTEM TROUBLE,
STC (LED #2)
1 FLASH = AC LOW/MISSING
2 FLASH = LBC LOW BATTERY
3 FLASH = Not Used
4 FLASH = NSC NO SERVICE
5 FLASH = RFC RADIO FAILURE
6 FLASH = DTF DIAL TONE FAIL
REGISTRATION
(LED #1)
ON = UNIT REGISTERED
OFF = UNIT NOT REGISTERED
If flashing with LED 4 = DENIED
(NACK)
,
Call Technical Support.
If all LED's flashing = NO RESPONSE,
Check Signal Strength.
SYSTEM STATUS LEDS
RSSI MODE
RSSI Value LED's Lighted
RF dBm
NO SVC LED 5*= flash, 4-2 = off n/a
1
LED 5 = on, 4-2 = off
< -111 dBm
1 ½
LED 5 = on, 4 = flash, 3-2 = off > -110 dBm
2
LED 5-4 = on, 3-2 = off > -100 dBm
2 ½
LED 5-4 = on, 3 = flash, 2 = off
> -90 dBm
(Minimum Signal Recommended)
3
LED 5-3 = on, 2 = off
> -80 dBm
3 ½
LED 5-3 = on , 2 = flash > -70 dBm
4
LED 5-2 = on
> -60 dBm
*Note: LED 1 ON INDICATES MORE THAN ONE TOWER
AC
LED 6
CAUTION:
INCORRECT CONNECTIONS
MAY RESULT IN DAMAGE TO UNIT.
LED MODE SELECT
EARTH
GROUND
STC2
(N.C.)
BATTERY
(12V)
BLANK PIN
AC
(12V 800MA)
TELGUARD DIGITAL TG-1
QUICK INSTALLATION GUIDE
INSTALLATION SUMMARY
There are four steps in installing Telguard properly.
IF YOU DO NOT
PROCEED IN THE ORDER AND MANNER PRESCRIBED, YOU MAY
NOT COMPLETE THE INSTALLATION IN THE TIME ALLOCATED.
Complete the Activation Form online at
www.Telguard.com
or fax the form
to Telular Cellular Service prior to leaving for the job site.
S
TEP
1: L
OCATE
U
NIT AND
M
EASURE
S
IGNAL
S
TRENGTH
(RSSI)
First, you will be confirming that Telguard has adequate cellular signal
strength. Put J10 across both pins, LEDS will now indicate signal strength,
minimum recommended is 2
½ (2
on solid and the third flashing).
S
TEP
2: R
EGISTER
T
ELGUARD
& T
RANSMIT
C/C A
LARMS OVER
THE
C
ELLULAR
R
ADIO
N
ETWORK
Next, you will be connecting the C/C's digital dialer output to Telguard and
verifying that alarm signals can be reliably sent through Telguard over
cellular to the central station digital receiver. The incoming Telco line is not
connected to Telguard during this step. A minimum of two alarm signals
must be transmitted.
(NOTE:
THE FIRST ALARM WILL REGISTER THE UNIT WITH THE
T
ELULAR
C
OMMUNICATION
C
ENTER
,
IT WILL NOT GO TO THE
C
ENTRAL STATION
,
ALL SIGNALS AFTER THE FIRST ARE SENT TO
THE
C
ENTRAL
S
TATION
)
S
TEP
3: C
ONNECT
S
UPERVISORY
T
RIP
O
UTPUTS
Next, you will wire Telguard's supervisory trip output to the C/C and then
test.
S
TEP
4: C
OMPLETE THE
I
NSTALLATION
Your last step will be to check the jumper setting of J10 (LED mode, open =
normal), attach earth ground, and permanently mount the unit.
56034101