background image

13

Power-Up Check

1.

Plug in any DC wallpacks that are being using with 
individual intercom stations. 

NOTE

: If you plug in DC wallpacks after applying power to 

the PS2001L or SPS-2001, you may get an overload 
indication. This is because the stations that are being 
powered by wallpacks will draw current from the units until 
their own DC wallpack supplies are connected. To correct 
the problem, plug in the DC wallpacks.

2.

Plug in the AC power cords for any connected PS-
2001L or SPS-2001 Power Supplies. The channel 
status indicators should be green.

3.

If a channel status indicator turns red during 
operation, locate the short or overload that is 
causing the problem. Once the short or overload is 
corrected, the Power Supply should reset itself and 
the overload indication should go away.

Specifications

General

Input Power Requirements

100 to 240 VAC, 50/60 Hz

Current Draw

750mA maximum (SPS-2001)

700mA maximum (PS-2001L)

Output Power (each channel)

24 ±1 VDC, 1 Amp per channel

Dimensions

1.75” (44.5 mm) high x 8.25” (209.5mm) wide x 10.31” (261.9mm) deep

Weight

approximately 2.5 lb. (1.13 kg.)

Environmental Requirements

Storage:

-20° C to 80° C, 0% to 95% humidity, non-condensing

Operating:

0° C to 50° C, 0% to 95% humidity, non-condensing

Intercom Channels (General)

Connector Type:

One XLR-3M audio connector for each channel. Pin-out depends on setting 
of BAL/UNBAL switch for balanced or unbalanced operation as defined 
below:

Balanced Mode (set to BAL position)

Line Terminating Impedance: 300 ohms ±10%

Connector Pinout

Pin 1     Common (audio and DC return)

Pin 2     Full-duplex, balanced intercom audio and +24 VDC output

Pin 3     Full-duplex, balanced intercom audio and +24 VDC output

Unbalanced Mode (set to UNBAL position)

Line Terminating Impedance: 200 ohms ±10%

Connector Pin-out:

Pin 1     Common (audio and DC return)

Pin 2     +30VDC ±1VDC

Pin 3     Full-duplex, unbalanced intercom audio high

Speaker Inputs (SPS-2001 only)

Type:

RCA Phone Jack

Tip:          S Input

Sleeve:    Speaker - Input

Approvals

UL, CUL, CE

Summary of Contents for Audiocom PS-2001L

Page 1: ...Model PS 2001L Power Supply Model SPS 2001 Power Supply 9350 7699 000 Rev E 9 2009 ...

Page 2: ...ast Cornhusker Hwy Lincoln NE 68507 U S A Attn Service This package should include the following FCC STATEMENT This equipment uses and can radiate radio frequency energy that may cause inter ference to radio communications if not installed in accordance with this manual The equipment has been tested and found to comply with the limits of a Class A computing device pursuant to Subpart J Part 15 of ...

Page 3: ...to your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the a...

Page 4: ......

Page 5: ...I INTRODUCTION 3 Description 3 INSTALLATION 7 Configuration Switches 7 Intercom Channel and Program Connections 7 CHANNEL CAPACITY 7 AUDIOCOM CONNECTIONS 7 CLEAR COM APPLICATIONS 7 Desktop or Rackmount Installation 8 Power Up Check 13 Specifications 13 ...

Page 6: ......

Page 7: ...com channels or one large intercom channel with twice the intercom station capacity Additionally the units can be configured for compatibility with Clear Com Intercom Systems The units may be rack mounted or used on a desktop For rack mounting optional hardware is required For desktop use four non marring rubber feet are supplied The SPS 2001 also provides a speaker with two mixed inputs making it...

Page 8: ...ne Isolate switch is set to the Isolate position each channel connector is powered separately and has completely separate intercom audio When the Combine Isolate switch is set to the Combine position each channel is still powered separately but the audio signals are combined so that all users on both channels can intercommunicate 5 BAL UNBAL Selector Switch This selector switch allows the user to ...

Page 9: ...ort circuit is located and fixed 4 Universal AC Power Input The unit accepts any input power in the range of 100 240 VAC 50 60 Hz 5 Intercom Channel Connectors When the Combine Isolate switch is set to the Isolate position each channel connector is powered separately and has completely separate intercom audio When the Combine Isolate switch is set to the Combine position each channel is still powe...

Page 10: ...6 ...

Page 11: ...1L or SPS 2001 determine the total current for all stations on each channel The total per channel should not exceed 1 0A If you exceed this limit an overload indication will be provided and the output of the power supply will be turned OFF Once the overload is corrected the overload indications will disappear and the power supply output will be turned ON Note if you are using DC wallpacks with som...

Page 12: ...on Pin 2 No connection Shield Cable Type 22AWG Stranded 2 Pair Twisted wire with Shield Channel Audio Power Pin 3 Channel Audio Power Earth ground Connector Type 3 Pin XLR Audio Neutrik or Switchcraft Pin 1 Common Pin 2 Shield Standard cables are generally constructed using a male connector at one end and a female connector at the other end This allows several cables to be interconnected to create...

Page 13: ...9 FIGURE 4 Typical connections using a single PS 2001L Power Supply to power two channels ...

Page 14: ...er Supply for two intercom channels The two program sources are monitored independently by their intercom channels All audio program and intercom is monitored as a monaural mix in the SPS 2001 speaker The US2000A is set for monaural speaker output default ...

Page 15: ...nitored independently by the intercom channels The SPS 2001 monitors intercom channel 1 and program 1 The SPK 1000 monitors intercom channel 2 and program 2 The US2000A is sent for binaural speaker output as described in the US2000A User Manual ...

Page 16: ... To of stations on channel 1 To of stations on channel 2 To of stations on channel 1 PS 2001L Channel 1 Power Combine Isolate Switch set to Combine PS 2001L Channel 2 Power Combine Isolate Switch set to Combine 1 1 1 1 1 1 PS L Optional CH 1 BAL UNBAL CH 2 CLASS 2 WIRING 1 5A 24VDC 100 240 VAC 60 50 HZ TELEX COMMUNICATIONS INC MADE IN USA INPUT 1 SPEAKER INPUT 2 LINE LEVEL 1 VRMS CH 1 BAL UNBAL CH...

Page 17: ...0mA maximum SPS 2001 700mA maximum PS 2001L Output Power each channel 24 1 VDC 1 Amp per channel Dimensions 1 75 44 5 mm high x 8 25 209 5mm wide x 10 31 261 9mm deep Weight approximately 2 5 lb 1 13 kg Environmental Requirements Storage 20 C to 80 C 0 to 95 humidity non condensing Operating 0 C to 50 C 0 to 95 humidity non condensing Intercom Channels General Connector Type One XLR 3M audio conne...

Page 18: ......

Reviews: