5.1. Normal menu

a. Input menu

The fi rst main menu allows you to select for the 
input signal: the

 frequency

 or 

channel

, the 

off set

 

channel mode only), the 

bandwidth

 and the 

 

preamplifi ers powering

.

INPUT

Freq:666.000

Bw:     8MHz

Preamp:  12V

    

INPUT

Ch:C45

Bw:     8MHz

Preamp:  00V

To make a change press the key   until the desired 
parameter fl ashes. Then, this fi eld can be changed 
by means of the keys    and  . 
 
You can select any output frequency value between 
177,5 - 226,5 MHz (VHF) and 474-858 MHz (UHF).

The decimal part depends on the frequency step 
selected  (

see extended menu b

 ). If the frequency 

step is defi ned as 125KHz, decimal part values 
allowed are: 0, 125, 250, 375, 500, 625, 750 and 875 
KHz. If it is a 166 KHz step, then the values allowed 
are:  0,  166,  333, 500, 666 and 833 KHz.

Possible COFDM Bandwidths are: 7MHz or 8MHz.
Available voltages to power preamplifi ers are: 0, 12 
and 24 Vdc

In the case of a shortcircuiting condition in the 

5. - Instructions for use

Insert the programmer in the front connector of 
the module (“PRGM”). First, the programmer’s 
fi rmware version will appear: 

PCT firmware

  version

------------

V:5.03

The fi rmware version of the COFDM – COFDM CI 
module is shown below: 

Unit

Firmware

version:

1.01

input connector (line power set to ON) the frontal 
LED will be blinking until it is fi xed.

b. Output menu

The next main menu shows the 

frequency or 

output channel

, the output off set (only in channel 

mode), the 

level control

 and the selection of 

output

 

mode

.

OUTPUT

Freq: 474.000

Bw:        8MHz

Lev:99 Norm.

   

OUTPUT

Ch:C21 Of:0

Bw:        8MHz

Lev:99 Norm.

To change the frequency press the key   until the 
desired parameter fl ashes. Then, this fi eld can be 
changed by means of the keys   and  .

In 

frequency mode

 you can select any output 

frequency value between 177.5 - 226.5 and 474 - 
858 MHz. The decimal part depends on the step 
of frequency chosen (

see extended menu b

). If you 

select a steps of 125 KHz the permitted values for 
the decimal part are: 0, 125, 250, 375, 500, 625, 750 
and 875 KHz. With a steps of 166 KHz the possible 
values are: 0, 166, 333, 500, 666 and 833 KHz.

In 

channel mode

 you  can choose an output 

Summary of Contents for TOX Series

Page 1: ...COFDM COFDM CI EN Ref 563401 User manual w w w t e l e v e s c o m ...

Page 2: ......

Page 3: ...ption 10 4 1 Introduction 10 4 2 Power supply unit 11 4 3 Amplifier 12 4 4 Universal programmer 13 5 How to use the product 14 5 1 Main menu 14 5 2 Extended menu 16 5 3 Parameters saving 18 6 Controlling the device 18 7 Distribution of 7 channels 20 8 Norms for rack mounting 21 9 Norms for cabinet mounting 23 A Channels table 25 COFDM COFDM CI ...

Page 4: ......

Page 5: ... connectors type F female Maximum output level dBμV 80 5 Output impedance ohm 75 Attenuation dB 15 Select General Consumption mA typ 24V 250 no CAM module inserted and without powering preamplifiers 24V 300 with CAM module inserted and without powering preamplifiers 24V 300 no CAM module inserted and powering preamplifiers 24V 340 with CAM module inserted and powering preamplifiers Index of protec...

Page 6: ...vel 1 129 dBμV typ DIN 45004B Max Power 16 W Frequency range 2 5 30 MHz Test socket 20 dB Gain 2 20 3 dB typ Maximum output level 2 129 dBμV typ DIN 45004B Power supply unit 5629 Mains voltage 196 264 V 50 60 Hz Total max current outpur 1 output 2 5 A 24V Output voltage 24V Max voltage per output 4 A 24V 1 2 Technical specs Broaband Amplifiers 1 3 Technical specs Power Supply Unit 1 4 Blocks diagr...

Page 7: ... unit 24VDC 5A T 0X Accessories 7234 Universal Programmer 5071 T03 T05 T 0X Mounting rail 50 cm 5239 T03 T05 T 0X Mounting rail 12 Modules PSU 56 cm 5301 19 Subrack frame 507202 T 0X Lockable cabinet with Ventilation Unit 7 Modules PSU 4061 75 Ohm DC Block load 4058 75 Ohm Load 422601 T05 to T 0X Power connection lead 40 cm 422602 T05 to T 0X Management connection lead 40 cm 422603 T 0X Management...

Page 8: ...DM COFDM CI UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI A B C BROADBAND AMPLIFIER TEST 30dB UAMP44 1 2 CLAC 3 Mounting 3 1 Wall mounting 7234 NOTE The use of both source outputs is recommended balancing the consumption For example 4 3 or 3 4 modules 5575 4061 5071 5239 563401 5629 COFDM input COFDM output ...

Page 9: ... rack mounting UPSU120 UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI UCC CI S COFDM COFDM CI UAMP44 BROADBAND AMPLIFIER PWR TEST 30dB 5301 ...

Page 10: ...lot for the insertion of a conditional access module CAM The programming of the transmodulator operating parameters input frequency output channel and adaptation of services mainly is performed through the universal programmer ref 7234 4 Identification of the system elements 4 1 Introduction 1 3 2 4 CAM UAMP44 CTRL PRGM COFDM COFDM CI PWR 6 7 9 5 8 1 COFDM input 2 COFDM output 3 RF input 4 RF outp...

Page 11: ...I S CTRL COFDM COFDM CI PWR NOTES The PSU can power a maximum of fourteen COFDM COFDM CI modules Whenever the demand of power exceeds 4A max current for each output it is necessary to distribute it between the two powering outputs of the PSU 24V OK 0V Overload or short circuit 24V 24V 24V 0V 0V 24V GND ...

Page 12: ... 5 6 7 UAMP44 BROADBAND AMPLIFIER PWR TEST 30dB 1 RF output 2 Test socket 3 RF input 4 RF input 1 Mains power supply input 196 264 V 50 60 Hz 2 Ground connection 3 Power LED 4 MATV input Return channel output 5 MATV input test 6 MATV output test 7 MATV output Return channel input 5 Powering BUS connectors 6 Status LED 7 Gain attenuator I max 150mA 196 264V 50 60Hz Fuse T1A L 250V USO EXCLUSIVO EN ...

Page 13: ... Selection of parameter posi tioning of the cursor Modification of the parameter chosen by the cursor flashing short press Change menu long press Change between Principal and Extended menus long press Save changes to memory Cloning menu Increases the contrast of the screen Decreases the contrast of the screen ...

Page 14: ...uctions for use Insert the programmer in the front connector of the module PRGM First the programmer s firmware version will appear PCT firmware version V 5 03 The firmware version of the COFDM COFDM CI module is shown below Unit Firmware version 1 01 input connector line power set to ON the frontal LED will be blinking until it is fixed b Output menu The next main menu shows the frequency or outp...

Page 15: ...ll as the total number of services in the multiplex the figure indicates that the 2nd service out of 8 services is available the statistics 18 25 the name of the service and if the user has selected it to be removed from the output OFF be unscrambled DCY or to pass through without modification ON Statistics xx yy indicate the following the first number indicates the percentage of the output occupi...

Page 16: ...8 Excessive temperature 9 10 If the maximum recorded is outside the optimal range the installation should be adjusted in order to reduce the temperature If the COFDM COFDM CI modules have been installed in a housing ref 5069 and the temperature of one of the modules is outside of the optimal operating range the ventilation unit ref 5334 will have to be installed To check whether this change is eff...

Page 17: ...user can change them NIT IDs Auto IDs Manual ts_id 0x04fC n_id 0x055F on_id 0x055F d Versions menu In this menu the user is shown the firmware versions for the unit and the COFDM FPGA modulator VERSION Fw 1 00 11 Mod 1 00 11 e LCN menu The next menu allows you to assign a channel number LCN Logical Channel Number to the existing services at the output marked ON or DCY in the services menu LCN can ...

Page 18: ...LED on the front of the unit indicates whether the COFDM demodulator is hooked it glows green when hooked and glows red when not 6 Controlling the Device This version of the COFDM COFDM CI allows configuration and monitoring via a PC both locally and remotely a Local control The Headend Management programme v2 14 or higher is required as well as a special cable provided with the programme that con...

Page 19: ... MONITOR Now 04 Max 05 reset MONITOR Occupancy 76 Max 80 MONITOR CBER 9 15E 5 OUTPUT Freq 474 000 Bw 8MHz Lev 99 Norm INPUT Freq 666 000 Bw 8MHz Preamp 12V Long press Menu structure IDs Manual ts_id 0x04fC n_id 0x055F on_id 0x055F LANGUAGE English LCN 1 3 Teledeporte NO LCN FREQ STEP In 166KHz Out 166KHz ...

Page 20: ...annels of COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI COFDM COFDM CI 5629 451202 75 ohm 4061 The diagram shows the assembly for the distribution of 7 channels of COFDM COFDM CI COFDM output 7 x 563401 ...

Page 21: ...kwiththeCOFDM COFDM CI is located in warm places with temperatures higher than 45 C These ventilators will be installed on a tray that is fixed inside the cabinet fig 1 2 This way the ventilators will force the fresh air entering from the base of the cabinet to circulate between the modules and be expelled through a gap on top of the cabinet 3 5 cm approx See fig 3 8 Norms for rack mounting max 49...

Page 22: ...is to facilitate the ventilation of the units fig 5 It is very important that this process operates correctly therefore the following must be observed Do not open the side doors as this would cause the ventilators to extract the air from the outside rather than the air inside the rack Do not place objects close to the rack that may block the entry and exit openings for the air If the rack is not c...

Page 23: ...net placement horizontal or vertical The maximum temperature permitted surrounding the highest cabinet is 45ºC in both ways of placement horizontal or vertical way EXTRACTOR for forced ventilation must be onto the highest module Horizontal placement Vertical placement Lower grid in any wall Maximum environment temperature 45ºC ...

Page 24: ... placement of the cabinets is strongly recommended hanging them as near to the floor as possible If the horizontal placement is impossible then vertical placement is allowed Respect the recommended minimum distances in the attached schemes Install the cabinet as low as possible Maximum T 45ºC ...

Page 25: ... 00 G 203 50 L07 194 75 R09 202 00 C27 522 00 C25 506 00 S10 242 00 6 177 50 C06 184 50 C26 514 00 26 503 00 H 212 50 L08 202 75 R10 210 00 C28 530 00 C26 514 00 S11 250 00 7 184 50 C07 191 50 C27 522 00 27 509 00 H1 219 50 L09 210 75 R11 218 00 C29 538 00 C27 522 00 S12 258 00 8 191 50 C08 198 50 C28 530 00 28 515 00 H2 226 50 L10 218 75 R12 226 00 C30 546 00 C28 530 00 S13 266 00 9 198 50 C09 20...

Page 26: ...1 794 00 61 713 00 C22 482 00 C22 482 00 C23 490 00 C63 810 00 C61 794 00 C28 530 00 S37 417 50 S40 458 00 C62 802 00 62 719 00 C23 490 00 C23 490 00 C24 498 00 C64 818 00 C62 802 00 C29 538 00 S38 424 50 S41 466 00 C63 810 00 63 725 00 C24 498 00 C24 498 00 C25 506 00 C65 826 00 C63 810 00 C30 546 00 S39 431 50 C21 474 00 C64 818 00 64 731 00 C25 506 00 C25 506 00 C26 514 00 C66 834 00 C64 818 00...

Page 27: ...762 00 C58 770 00 C63 810 00 H47 662 50 C54 738 00 C58 770 00 C58 770 00 C59 778 00 C64 818 00 H48 669 50 C55 746 00 C59 778 00 C59 778 00 C60 786 00 C65 826 00 H49 676 50 C56 754 00 C60 786 00 C60 786 00 C61 794 00 C66 834 00 H50 683 50 C57 762 00 C61 794 00 C61 794 00 C62 802 00 C67 842 00 H51 690 50 C58 770 00 C62 802 00 C62 802 00 C63 810 00 C68 850 00 H52 697 50 C59 778 00 C63 810 00 C63 810 ...

Page 28: ...COFDM COFDM CI 28 ...

Page 29: ...n force at the time of purchase is applied Keep the purchase invoice to determine this date During the guarantee period Televés S A complies with the guarantee by repairing or substituting the faulty equipment The harm produced by improper usage wear and tear manipulation by a third party catastrophes or any other cause beyond the control of Televés S A is not included in the guarantee ...

Page 30: ......

Page 31: ...EN 31 ...

Page 32: ......

Reviews: