background image

Ref.769201 CoaxData™

 1Gbps HDTV

 

Ref.769202 CoaxData™ 

1Gbps HDTV  c

on SFP

Ref.769203 CoaxData™

 1Gbps HDTV 1xEth

Ref.769201/769202/

769203 

CoaxData™ 1Gbps

Manual de Usuario

Summary of Contents for CoaxData 769201

Page 1: ...Ref 769201 CoaxData 1Gbps HDTV Ref 769202 CoaxData 1Gbps HDTV con SFP Ref 769203 CoaxData 1Gbps HDTV 1xEth Ref 769201 769202 769203 CoaxData 1Gbps Manual de Usuario ...

Page 2: ...Netwoking Coaxial Option 17 Home Networking PLC Option 17 Home Networking Hybrid Option 18 Application Examples Shared Networks in Buildings 19 Shared Networks Cheking Coaxial Cable 19 Shared Networks Basic Installation 22 Shared Network Several Masters in Coaxial Header 22 Professional and Special Applications 25 Professional Application Types of Line Amplifiers 26 Line Amplifier Passive Diplexer...

Page 3: ......

Page 4: ...in excessively moisture conditions Do not place the equipment where it may be affected by strong vibrations or knocks How to use the equipment safely The powering supply of this product is 108 254 Vac 50 60 Hz If any liquid or object falls inside the equipment please contact a specialized technician To disconnect the equipment from the mains pull from the connector and never pull from the cable Do...

Page 5: ...supply two F connectors for TV and data connectors and one RJ 45 Ethernet 1000BASE T 100BASE TX 10BASE T Only supports coaxial medium Ref 769201 CoaxData 1Gbps HDTV Ref 769202 CoaxData 1Gbps HDTV con SFP Ref 769203 CoaxData 1Gbps HDTV 1xEth Main Features Connect your computer to the Internet access services using existing wiring in your building Easy installation no need to open the computer or in...

Page 6: ... queues Supports IGMPv3 multicast management streams for efficient implementation of IPTV or VoIP systems allowing the management of up to 32 different channels AC Power Supply 108 254Vac 50 60Hz on the device and low power mode to save energy by consuming less than 2 watts Configuration software Toolkit Compact and robust design that meets all legal regulations applicable to product safety EN 609...

Page 7: ...ice VoIP phones set top boxes televisions etc Autonegotiation features for maximum link speed and Auto MDIX which avoids the use of Ethernet crossover cable SFP Port Only 769202 Ref 769202 replaces one Ethernet for an SFP This connector allows the use of singlemode multimode fiber modules compliant with1000BASE LX 1000BASE SX 1000BASE CX standards or or SFP devices built in modules that support ne...

Page 8: ...n using this button because if modems are configured on MxU mode this button will remove that setting and set defaults operating mode HomeNetworking CoaxManager Advanced Features can disable factory button so that user settings cannot remove when press button Medium Switch On the front is a switch to switch between only coaxial medium right and hybrid mode left where signal is transmited on coaxia...

Page 9: ...n transmit high speed rates Ethernet State LED This LED will light when an Ethernet link is established and will blink when transmitting data Autonegotiation feature is used to link with highest speed as possible Included are two LEDs 1Gbps When link speed is 1Gbps after autonegotiation 100 10Mbps When link speed is 100 10Mbps after autonegotiation SFP State LED Only 769202 LOS Light optical signa...

Page 10: ...Unit This mode uses existent coaxial network on building or house from the headend to communicate with coax outlets and provide access to multiple dwellings avoiding communicate with each other In this mode have two elements MDU Master Typically installed at the distribution headend manages all network elements and can be plugged to an ADSL modem or any other device provided by ISP Internet Servic...

Page 11: ...lets or power sockets of house Connect modems to devices demmanding internet access such as set top boxes printers and PCs using an Ethernet cable In a typical installation of Internet access one modem is connected to the Internet Router Operator 4 and other modems to get internet access 5 CoaxManager modes Only Coaxial Hybrid must correspond with medium switch selection on the front of device Fig...

Page 12: ...stallation of CoaxData 1Gps HDTV The figure below shows a schematic of how to connect the CoaxData 1Gbps HDTV to header installation MDU Master to distribute the available data services Internet Video Streaming VoIP to dwellings MDU Slave EN www televes es ...

Page 13: ...s necessary to have a DSL router Docsis cable modem or similar devices which provide Internet access Usually you need a class Ethernet cable CAT 5 or CAT 6 Connect to Coaxial Network You should connect master to coax network through a internal diplexer filter of coaxData devices that suppresses interfering noise of coaxial header Diplexer function mixes TV and data signals with a minimal loss 1dB ...

Page 14: ...ne of the modems operate in master mode which will be installed at the head the rest of the modems will be installed in the sockets and must be configured in slave mode by CoaxManager Connect Modem to PC CoaxData 1Gbps HDTV is equipped with two connectors that support Ethernet 1000 100 10 Mbps speeds with auto negotiation enabled which allows to reach the maximum possible speed and incorporates MD...

Page 15: ...anently on slaves and master In the case Link Status is off when connect modem check connections and verify coax installation Now your PC is connected to coaxial data network through TV distribution Consider the characteristics of your network Coaxial All Coaxial network elements must support working band 2 to 67 5 MHz This includes items such as outlets taps splitters and line amplifiers Maximum ...

Page 16: ...nstallation without additional infrastructure The following diagram shows a typical installation in which a user can access the different services offered by the Internet anywhere in the casa Tambien can share printers and multimedia servers located in other rooms Home Networking PLC Option BASIC INSTALLATION CoaxData allows create local network through the powerline grid infrastructure PLC The ma...

Page 17: ...and play home network This allows the creation of a LAN where all devices communicate with each other peer to peer P2P This application is used both household infrastructure coaxial cable and power cord for data transmission COAXIAL PLC So any TV outlet or plug power can be an access point to the LAN EN www televes es ...

Page 18: ...em you must know whether the network has its return channel in optimal state This requires the following equipment Advanced coaxial network analyzer to measure the noise in the return channel as Televes H45 or H60 spectrum analyzers Signal Noise Generator ref 5930 CoaxData Gigabit Diplexer filter ref 769220 Data 2 65Mhz and TV 87 2150Mhz Signal Noise Generator ref 5930 CoaxData Gigabit Diplexer fi...

Page 19: ...dend ref 769220 for example Step 2 Coaxial Network Noise Measure Then do the same measure but this time with the distribution network This is done by connecting the input H45 H60 to distribution network and checking that the noise generated by all elements in the 5 30 MHz return channel never exceeds 25dB V μ If the measurement exceeds the reference value 25dBuV must identify that point of the dis...

Page 20: ...CoaxData 1Gbps HDTV Ref 769201 Ref 769202 20 EN www televes es ...

Page 21: ...e When coax distribution is in tree topology several masters exists on same coaxial Every master create a Associated Logical Virtual Network shorted AVLN and can manage their associated slaves This architecture requires different network password for each AVLN to identify them On Star Topology installation of several masters in different branches of coaxial infraestructure increases the effective ...

Page 22: ...ed to ensure a high isolation avoiding interference between adjacent networks using diplex filters Installing ref 769220 diplexer filter on coaxial input on each home prevents neighboring networks interference with each other and header noise interfere with data and decreases link quality Diplexers filters determine master network range and also allows installation of multiple networks within a bu...

Page 23: ...LN and identified by different network passwords This network password is set by the program CoaxManager The password must be different in each of the masters AVLNs and each slave must be set with the master password with which the slave wants to communicate There is a limit to the maximum number of modems that can deliver a AVLN 1 master 253 slaves Using four modems teacher can increase the limit...

Page 24: ... system generates signals from both of the slaves connected to the sockets as from master at the head This implies that in line amplifiers return channel should be passive in order to ensure its bidirectionality It will present an outline of installation where two modems are used ref 769 201 in a configuration called repeater allowing regenerate the data signal and increase the range of the networ...

Page 25: ...nel are unidirectional ie only amplify the signal from the headend to the outlet forward channel or from TV sockets to headend return channel This prevents data communication because CoaxData is a system that requires two way communication between the head and the socket on return path without return path Do not allow transmission of the data signal on return path Passive return path Allows pass o...

Page 26: ...iplexer filter In networks where only line amplifiers with active return path are installed a solution with two chained diplexer filters can be used to separate fordward and return paths and install a passive return path bidirectional This solution enables the management of the entire network from a single point with CoaxManager ...

Page 27: ...on network because CoaxDATA modems are used like signal repeaters and regenerate data signal like line amplification Secondary network is installed with new added CoaxData master and where another network is generated The disadvantage is impossibility of remote management of secondary network from headend point since management cannot bypass multiple coaxData networks ...

Page 28: ...ss using CoaxData modem plus external diplexer filter Is a solution which combines the previous two and is valid in cases where high isolation is required due to the presence of high gain active return channel amplified in line amplifiers This solution increases the isolation between the two data networks avoiding interference between them ...

Page 29: ...nnection to a multimode fiber network compliant with 1000BASE X Gigabit standard SFP module enables CoaxData connect to provider optical fiber networks Figure shows an case where ISP operator provides high speed 1000BASE X fiber network with 8 different networks where each conduit is formed by three fibers one for TV RFOG and two for data for bidirectional transmission ...

Page 30: ...nd television signal RFOG at 1550nm This solution allows the distribution of the services on one fiberline infraestructure without the need of point to point architecture and saves the economic waste in the fiber installation The SFP used must be compatible with bidirectional transmission of a single multimode fiber WDM allows mixing and unmixing of the three signal wavelengths The example illustr...

Page 31: ... Master Slave Network Key For questions about how to configure the modem See CoaxManager Manual In MxU Installations some modems don t appear If any slave modem is installed fails or does not appear in the device list check the following assumptions Verify slave modem is operating CoaxManager can connect to and leds are lighted Coaxial Hybrid led link state led and Ethernet leds Check led colours ...

Page 32: ...s possible replace by amplifiers with passive return path or by a bypass with diplexer filters as shown in this manual Consider all elements of coaxial network like outlets taps or splitters and check support operating bandwith 2 to 65Mhz Check coaxial network attenuation on return path The attenuation between modems should not exceed 85 dB in the operating channel 2 to 67 5 MHz Calculate estimate...

Page 33: ...ur transmission queues prioritized VLAN IEEE 802 1p prioritization Type of Service ToS and COS Class of Service Source Destination MAC Address Classifier Source Destination IP Address Classifier Other adjustable classifiers filters AC and Consumption 108V 254V 50 60Hz Consumption Max 6 Watts Low Power Mode Advanced Power Management Max 1 8Watts Metodos de Transferencia HomeNetworking Asynchronous ...

Page 34: ......

Reviews: