![Televes CoaxData 769201 Manual Download Page 15](http://html.mh-extra.com/html/televes/coaxdata-769201/coaxdata-769201_manual_1082552015.webp)
Televes
®
15
Connect Modem to CEI Coaxial Socket:
Typically coaxial network distribution ends on a CEI
Outlet TV. To connect modem to outlet follow next steps.
•
Connect CEI Female coaxial cable end to CEI male connector of TV Outlet.
•
Connect CEI Male cable end to modem TV+Data input, F connector, via an CEI-M to F
adapter.
If device is properly connected to coaxial, LED "Coaxial Link Status" must light on permanently on
slaves and master. In the case Link Status is off when connect modem check connections and verify
coax installation.
Now your PC is connected to coaxial data network through TV distribution!
Consider the characteristics of your network Coaxial:
All Coaxial network elements must support working band
2 to 67,5 MHz
This includes items
such as outlets, taps, splitters and line amplifiers.
Maximum coaxial attenuation between header and outlet should not exceed
85 dB
in working
channel:
2 to 67,5 MHz
Modem comes with tools for rapid assessment of data network state once installed.