Important safety information

Main installation considerations

Please read this manual carefully before installing the product.

To reduce risk of fire or electrical schock do not expose the equipment to rain or dampness.

Do not remove product cover while being connected to the mains.

Do not block ventilation holes on the product.

Please allow for some free space around the product to guarantee proper air circulation.

Product   should   not   be   exposed   to   watter   splash.   El   aparato   no  debe   ser   expuesto   a   caídas   o 
salpicaduras de agua. 

Do not place product near heat sources or high humidity enviroment.

Do not install  the equipment in an unstable or vibrating surface where it could face a schock.  

Safe operation

Mains power requirements for this product are: 108-254 V~ 50/60 Hz.

Should any liquid or object fall inside the product, please refer to  technically qualified service. 

To unplug the product from the mains please pull from the mains plug, never from the electrical 
cable.

Do not connect the product to the mains untill all other connections have been made.

The power socket should be near the equipment and easily accessible. 

Electric security markings

CE marking compliance.

Product for indoor use.

Safety requirements for class II electrical products. 

Waste management of electric and electronic equipment at the end of their working live.

www.televes.es

E

N

G

L

IS

H

Summary of Contents for 769301

Page 1: ...Ref 769301 Data Over Coax Gateway ...

Page 2: ...2 Device Status 12 Setting up WAN mode 17 AP Bridge Mode 17 Router Mode 17 Setting up LAN interface 18 WiFi interface set up 19 Configuration of the radio interface 20 WiFi Access Point Configuration 22 Multiple VAP Restrictions 23 Security configuration of WiFi network 23 Setting WPS 25 Create custom Bridges and Vlan interfaces 26 System Interfaces description 26 Operation Modes 26 Creating VLAN ...

Page 3: ...ation 35 Changing account password 37 Device Management 38 Log Management 39 User Web account 40 Installing Data Over Coax Gateway 41 Setting up Coaxdata Master 42 Connecting CoaxData Master 42 Install 769301 Slave on TV outlets 43 Specifications 45 ...

Page 4: ...sources or high humidity enviroment Do not install the equipment in an unstable or vibrating surface where it could face a schock Safe operation Mains power requirements for this product are 108 254 V 50 60 Hz Should any liquid or object fall inside the product please refer to technically qualified service To unplug the product from the mains please pull from the mains plug never from the electric...

Page 5: ...100 BASE TX 10 BASE T to allow the connection of multiple devices such as PC s Set to boxes video game consoles etc WiFi 802 11bgn interface with 2x2 MIMO in the 2 4GHz band supporting up to 144 Mbps for 20MHz channels and up to 300 Mbps for 40MHz channels Posibility of switching off WiFi or selecting a low power mode interface by means of front panel switch WPS Wireless protected setup button fea...

Page 6: ... different channels Wide range power supply unit 108 254Vac 50 60Hz Robust and compact design in compliance with electrical safety legal requirements EN 60950 1 2007 AC 2012 electromagnetic compatibility EN 55022 2008 inmunity EN 55024 2011 and radiation over electric power wiring EN 50412 2 1 2006 and electromagnetic spectrum EN 300 328 V1 7 1 EN 62311 2008 Web interface to configure working para...

Page 7: ...Televes 7 Package content Ref 769301 Data Over Coax Gateway User guide 75 Ohm Coaxial load Euro Power Cord Data Over Coax Gateway Setup guide 75Ohm load Power Cable www televes es ENGLISH ...

Page 8: ...769203 CoaxData 1Gbps HDTV 1XEth Ref 769220 CoaxData Diplex filter TV Data 2 68 Mhz 87 2150 MHz Ref 769210 CoaxData SFP 1000 Base X 2 F O ethernet adapter Ref 769201 CoaxData 1Gbps HDTV Ref 769202 CoaxData 1Gbps HDTV with SFP Ref 769203 CoaxData 1Gbps HDTV 1x Eth Ref 769210 CoaxData SFP Module 1000 Base X Ref 769220 CoaxData 1Gbps diplex filter TV Data 2 68 Mhz 87 2150 MHz www televes es ENGLISH ...

Page 9: ... a period under 5 seconds the device will reboot if the button is pressed for more than 5 seconds it will reload factory configuration Please take into consideration that factory default will delete all configuration done on the equipment Configuration of coaxial interface of the product will be affected by this button and reset to factory Please note this as this is managed by using the CoaxManag...

Page 10: ...alised the WPS mode will stop and should a connection to a different device be needed the WPS button should be pressed again WiFi switch WiFi Switch allows three positions and hence WiFi status OFF left radio is off LED will bright red indicating that device has been turned off WiFi Low Power Center WiFi radio will be on in low power mode This mode will reduce exposure to radiation and interferenc...

Page 11: ... gateway supplied by the ISP Orange The device has been configured to AP Bridge In this working mode there is a bridge between the three interfaces Ethernet Coaxial PLC WiFi WLAN LED This LED shows the status of the WiFi network Green WiFi is On Maximum output power 17 dB Orange WiFi is ON in low power mode Maximum output power is 3 dBm Red WiFi en OFF Medium Coaxial Hybrid LED Shows the selected ...

Page 12: ...he IP address http 172 16 0 1 Default user is Admin and default password is Televes1 To increase security change account password through configuration options on the Device Management section If you forgot Username and or Password please reset equipment to factory configuration with factory button Press button for at least 5 seconds Device Status Device Information Information about firmware and ...

Page 13: ...onnection Name 1_INTERNET_B_VID_0 Protocol PPPoE_Bridged Router mode In this mode the option shows information related to the conection stablished by the ISP s router In this mode there is a WAN interface Coaxial PLC and interfaces for the LAN network Ethernet WiFi Service Mode Internet Connection Name 1_INTERNET_R_VID Default Gateway Subnet Mask IP address being giben by the ISP s gateway DNS Ser...

Page 14: ...on this interface User Information Information is supplied on the LAN interfaces and status of the WiFi interface working mode and packets counters Scan for Wireless Networks Provides information of current wireless channels that are active and the method of authentication to connect to them www televes es ENGLISH ...

Page 15: ...Televes 15 Ethernet Information Shows assigned IP address LAN IP address as well as packets counters of each three Ethernet interfaces www televes es ENGLISH ...

Page 16: ...ta Over Coax Gateway Ref 769301 16 Advanced LAN Info Provides additional information of the status of the LAN including ARPs table or IPs assigned by DHCP if this service is active www televes es ENGLISH ...

Page 17: ...allowed This type of network is mostly indicated for home use NOTE When AP Bridge Mode is set CoaxManager Pro application can be used to configure the coaxial plc interface Router Mode Router This is the factory default working mode Under this mode the device will route between the coaxial plc WAN interface and the Ethernet WiFi LAN interfaces In this mode the CoaxManager Pro can only be used to c...

Page 18: ...ion needs a PPPoE server on the WAN side User PPPoE user name Password service password Connection Trigger Indicates wether the connection is stablished On demand or always On Setting up LAN interface The product includes a LAN interface to stablish connection between the local devices and internet and to build a bridge between the ethernet ports and the WiFi network LAN Settings This options conf...

Page 19: ...d restore to original values Wireless Info Provides information about the state of Wi current channel and the number of stations currently connected to AP Scan for wireless network Provides channel information of wireless AP that are active the channels occupied and methods of authentication This option allows you to to select the most appropriate AP channel depending on the already occupied chann...

Page 20: ...ntrolled by the switch located on the front pannel of the product and is not available on web In case you want to use this option you need to disable wifi switch on web page in Device Management Advanced Management WiFi Mode Selects the WiFi mode Standard Description 802 11b 802 11 supporting 11Mbps througput 802 11g 802 11 supporting 54Mbps througput 802 11ng20 802 11n supporting 144Mbps througpu...

Page 21: ...er of the WiFi network RF power will be set by the working mode of the WiFi Network Maximum allowed power for a WiFi network 17dBm will not en exceeded Minimum RF power will be 3dBm Power is controlled by three position switch on the front of the device so your settings will be changed depending on the position of the front switch In case you want to disable the wireless switch change disable swit...

Page 22: ...tory default mode AP This mode is similar to the Root AP but with the WDS mode deactivated as this protocol might not be supported by all WiFi enabled devices In this mode there is no transparent bridge between WiFi devices and the ethernet ports WiFi user will only have access to the WAN interface WDS Station This mode allows the product to work as a WiFi client of other WiFi networks It activate...

Page 23: ... environment with multiple VAPs if one of them is a Station WDSStation activation of WPS on VAPs are not allowed This is because when multiple VAPs are defined pressing WPS button causes device station VAPs init WDS session and try to establish connection with AP for which the has been configured ant the other AP VAPs stop their transmissions To avoid this WPS option at VAPs is not allowed Securit...

Page 24: ...SK WPA2 PSK WiFi Protected Access Wireless protected access Improved security protocol for WiFi networks WPA2 is the last version of this protocol WPA Passphrase key WiFi network password Default password is Televes1 Encryption method WPA WPA2 TKIP Encryption method for WPA WPA2 AES Encryption method for WPA WPA2 This is the most robust encyption method and recommended option WiFi Authentication S...

Page 25: ...on the device you want to connect to the wireless network Although initially the PIN was to consist of 8 decimal digits the router allows the introduction of digits and characters of any length in order to increase security in the field It is recommended that if you use WPS PIN to establish wireless access only desired wifi users should know PIN to avoid unwanted access to network If you want to d...

Page 26: ...rface ath0 This interface represents the device s wireless access point There is typically a single VAP CoaxData DoC Wifi ath0 in AP mode The device would accept the configuration of more VAPs that internally would be named ath0 ath1 etc Default Bridge br0 This bridge is created in the device between the Ethernet eth1 and Wireless ath0 interfaces to provide ethernet bridge between the Ethernet and...

Page 27: ...igured in the device will be displayed A standard notation is used on this document to identify the interface and packets with VLAN tags transmited over that interface consisting on the interface name followed by the corresponding VLANID For example packets with VLANID tag 10 on the Coaxial eth0 interface will be marked with eth0 10 Creating VLANs on the device s Switch Ref 769301 has an internal ...

Page 28: ... through this interface Untagged All untagged traffic arriving to this interface will be considered a member of the VLAN Also VLAN traffic will be transmitted over this port without any kind of Tag Tagged All traffic with the specified tag will be assigned to this VLAN This VLAN traffic will be transmitted through this port with the specified Tag Once established a VLAN entry in the switch it has ...

Page 29: ...mple VLAN 100 configures the CPU Port as Tagged eth1 100 interface is created so it can be used and added to a particular bridge Creating Bridge interfaces on the device In order to transmit or receive VLAN tags on the device it is necessary to create a Bridge on the device and then add the interfaces that operate in it The function of the bridge is to allow communication between different interfa...

Page 30: ...reated with a VLANID tag VLAN Interfaces These interfaces correspond to the tagged packets on the corresponding system interface This would be Coaxial Ethernet or Wifi interface configured with an specific VLAN ID tag When an interface is added to a bridge it will not be available for other bridges of the system since an interface can be added only to one Bridge Add Adds an interface to a Bridge R...

Page 31: ...he bridge br vlan10 in this example According to this configuration Router All untagged packets will be routed normally br vlan10 A bridge is create between Coaxial interface eth0 10 and Ethernet interface eth1 10 which allows packets with tag VLAN 10 to pass directly from the Coaxial to Ethernet and vice versa www televes es ENGLISH ...

Page 32: ...Restore Factory Enable Factory Defaults of CoaxData Option allows when a factory defaults is performed on the device by pressing the button or through the web page they also do a factory defaults in CoaxData modem This implies that the coaxial modem settings established by CoaxManager such as the transmission mode and mask QoS rules or prioritization will be restored to their default values Wifi S...

Page 33: ... will not be performed Enable Performs test periodically when timer expires LAN WLAN Activity default configuration perform the test only if activity is detected on the device This activity is measured as receiving packets from the Ethernet LAN or WLAN connection This option saves bandwidth on the device since the devices that do not have any active user does not perform any test Test Timer Allows...

Page 34: ...nterfaces Static Router Table It is possible to manually set IP routes Tis routes are defined with the following information Destination network Defined with a set of an IP address and a mask For example 10 0 0 1 255 0 0 0 Gateway The router which will forward the traffic to their final destination The IP address of the gateway has to be within the same network range as the device Setting up syste...

Page 35: ...t the VoIP telephone has been identified This will be done in a transparent mode for the end use without the need of further configuration DMZ host Demilitarized zone host In this option a host on the LAN will have all ports open except thoses mentioned on the NAT section see next option NAT Mode Select most appropiate NAT Type on device Linux Native more restrictive Allows a port from an external...

Page 36: ...host are denied Cone less restrictive Allows from any external host hAddr hport can be connected to a device on the LAN iaddr iPort sending packets to WAN port eAddr ePort This option once the connection has been established on the NAT any external host and port to connect to the service provided Depending on the service that users require the right type of NAT should be established So for simple ...

Page 37: ...l in this case Changing account password This option allows the change of the username and password to access the web interface of the product It is strongly recommended to change de default user and password to increase security of the system Through the save and load configuration options it makes it easier to simplify the configuration of set of devices on a system The Reset option will load fa...

Page 38: ...d Configuration Loads the configuration on a device After the loading has finished the devoce will reboot and start with the new parameters Firmware upgrade This option will load a new firmware to the device This file can only be supplied by Televes Upgrade process might take up to 3 minutes and the product should not be powered off during this process as could cause permanent device malfuncion Re...

Page 39: ... Debugging Access Records Shows system events The system also allows you to enable remote logs using network support and configure a remote server for receiving them Network Support Network Support Enables sending of logs generated by the system to a remote server to store them for later review Hostname IP Destination Server name or IP destination address to which the logs will be sent By default ...

Page 40: ...om the Web Interface with the following parameters Username username Password 123456 Next picture shows available options for user account This page user settings allows the installer provide access to local management of the device without provide access to critical WAN Coaxial settings in such a way that user can configure local network of the device User also can provide a new username and or p...

Page 41: ...s an MxU slave to be able perform a plug and play installation This configuration assumes that there is a Televes mxU Master 769201 769202 or 769203 connected to a gateway with internet access Ref 769301 performs as an slave on the access points of the coaxial network www televes es ENGLISH ...

Page 42: ...Data Master device on the headend builds two connections Conection to the Router Gateway connected to the Internet To get acces to the Internet the Master hast to be connected to the Router gateway connected to the Internet by means of an Ethernet cable Connection to the coaxial network To connect the master to the coaxial network it is recommended the use of a diplex filter to supress the ingress...

Page 43: ...rivers Working mode Master Slave Ref 769301 is configured to MxU Slave mode Therefore it will automatically connect to the system Master device Please note that all other devices on the network must be set to MxU Slave mode using the CoaxManager Software Connection to a computer The Data Over Coax Gateway includes 3 ethernet ports supporting 100 10 Mbps It supports speed autonegotation and MDI X a...

Page 44: ...e to the wall socket Please note that this wall socket must be return path capable Connection to the TV Connect using a coaxial cable the TV F port on the device to a TV reception system or a set top box If all devices are correctly connected the Coaxial Link Status LED should bright in the master as well as in all slave devices Please take into consideration the default configuration of your Data...

Page 45: ...ission conditions both in the coax PLC medium Syncrhronization to power as condiciones del canal coaxial y frequency 50 60 Hz OFDM 2880 carriers QAM 4096 1024 256 64 16 8 QPSK BPSK ROBO mode FEC forward error correction TCC Turbo Convolutional Codes error recovery Range Coax Cable 1 2Km PowerLine 300 m Quality of Service QoS Multicast IGMP snooping MLDv2 IGMPv3 IGMPv2 Four priorization queues VLAN...

Page 46: ......