background image

CATV & DOCSIS3.0 Meter / Analyzer

EN

Refs. 593101, 593102

593103, 593104
593160, 593180

Instruction Manual

w w w . t e l e v e s . c o m

Summary of Contents for 593101

Page 1: ...CATV DOCSIS3 0 Meter Analyzer EN Refs 593101 593102 593103 593104 593160 593180 Instruction Manual w w w t e l e v e s c o m ...

Page 2: ......

Page 3: ...peration 10 Docsis 3 0 10 Docsis 3 1 12 Channel info 14 System scan 15 Tilt 16 Spectrum 16 Constellation 15 CTB CSO 17 Voltmeter Hum 19 Equalizer 20 Learning plan 21 Ingress Scan 21 Speed Test 22 MPEG Info 22 LT Monitoring 23 FM Scan 24 Wifi Analyzer 24 Setup 25 Ethernet Features 26 Network setup 26 Firmware update 26 Remote Control 27 Aplication Program Interface 35 Maintenance 36 Technical suppo...

Page 4: ...anty and may pose a risk of fire or electrocution Wire Protection Ensure all connected wiring is routed correctly to avoid damage including pinching excessive bends or compression Electrical Supply Grounding and Surge Protection Ensure that all local or national electrical codes are followed Power Lines Always use caution and avoid operating this or any connected equipment near uninsulated power l...

Page 5: ...asurements with easy to read pass fail indicators Quick and easy to use interface with features such as Channel measurements System Scans Tilt Function Constellation Diagram Spectrum Analyzer Voltmeter Hum Service Identification option 593210 Datalogger and more Rugged light weight fully automatic fast and accurate Automatic through the cloud software updates 100 automatic ITU T J 83 Annex A B C p...

Page 6: ...smart battery 7 2VDC 2300mAh Operating Time Up to 4 hours Operating Temperature 23ºF to 104ºF 5ºC to 45ºC Storage Temperature 4ºF to 158ºF 20ºC to 70ºC Humidity 5 to 95 non condensing Ruggedness Survives 1 m 3 ft drop to concrete on all sides Communication Interfaces RJ45 10 100 T and 1000 T for 593103 593104 and 593180 Ethernet interface for Remote Control Measurements Datalog Retrieval and Autom...

Page 7: ... all channels analog and digital Selectablemarkers Pass Fail Indicators Factory profiles Headend Fiber Nod Trunk Bridge Line Ext Tap End Line Ground Modem STB Off Air Custom profiles up to 20 profiles Voltmeter Range 9V to 150V Accuracy 0 5V 1 Hum Range 2 to 5 Accuracy 1 SpeedTest Option593211orReference593180 DCHP Status Connection Status Ping Lost packets DS US speeds Up to 20Mbps ServiceInfo Op...

Page 8: ...rn the equipment off press and hold for approximately 3 seconds 2 Back button Return to the previous menuorcloseaparameterentrywindow 3 Home button Return to the main menu 4 Rotatingselector Usedtoscrollthrough options 5 OK Button To confirm selection 6 Setup button Parameter window for the current function 7 LED Load Indicates if the equipment is powering an external load 8 LED Charging Battery I...

Page 9: ... charge between 5 and 25 Battery charge between 25 and 50 Battery charge between 50 and 75 Battery charge greater than 75 From a fully discharged state a full charge takes approximately 8 hours and a 3 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature Battery Recommend...

Page 10: ...level of security BPI BPI the DOCSIS version and the channel bonding configuration 1 1 1 Main window Below is a capture of a Connection window with a brief explanation of its features Steps that the meter must be completing Indicators that show the state of the processes Parameters of the DOCSIS network MAC of the DOCSIS modem Connection Status 1 2 Measurements This function shows the status of al...

Page 11: ...peed value is constantly updated 1 3 1 Main window Below is a capture of a Throughput Test window with a brief explanation of its features URL set by the user Transfer status Transfer speed Current PING delay Average PING delay Transmitted and received packets Modem IP within the DOCSIS network Maximum DS and US speed negociated Lost packets 1 4 Modem Emulation This function sets the H30 to be use...

Page 12: ...g FTP Path Enter the file path using Method GET PUT GET selects the upstream channel and PUT select the upstream for the FTPTest in the Troughput test feature User Enter the user for the FTP server Pass Entertheappropriatepasswordforthefor the FTP server user PingTest These parameters allows to set the IP to do the Throughput test IP Enter the IP address using Count Enter the number of PINGs to do...

Page 13: ...to Selected channel Change using 2 2 2 Setup Press to change Spectrum options Span 2 5MHz 6 25MHz 12 5MHz 25MHz 62 5MHz 125MHz 250MHz 500MHz Full Set the span of the spectrum To easily change the span use the OK Button to decrease the span and the Back Button to increase the span dB div 5 dB div 10 dB div Tuning Channel Frequency A D Auto Analog Digital Ref Level Select the reference level of the ...

Page 14: ... graph min hold Selected frequency Change using 2 Channel Info Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques provided in the Televes H30 In analog mode video and audio levels V A and Carrier to Noise C N are measured In digital mode it s Power C N Pre BER and Post BER 2 1 Main window Below is a capture ...

Page 15: ...heir green yellow and red bars This gives an easy to understand real time view of the system including the BER and MER values of the selected channel 3 1 Main window Below is a capture of a System Scan window with a brief explanation of its features Bar graph representing all the found channels Color according to checkmarks Channel plan Measurements of the selected channel with pass fail indicator...

Page 16: ...all the channels Color according to checkmarks Tilt measurement between the selected channels Selected channels Change using 4 2 Setup Press to change the Tilt options Ref Level Select the reference level of the bar graph Plan FCC STD FCC RETURN FCC IRC FCC HRC FCC OFFAIR CCIR Custom plans Channels Select the channels to show in the bar graph Save datalog Saves the current scan measurements You ca...

Page 17: ...emote control application 6 Constellation Digital video often does not show signal impairment until it is too late due to the small margin between acceptable quality and failure Constellation diagrams are an indispensable tool to help detect the presence of noise phase jitter interference and gain compression all of which impact overall signal quality and thus reduce Modulation Error Ratio MER Ide...

Page 18: ...TB CSO Cable TV networks are generally located in densely populated areas or extend over large geographical regions This makes cascading large numbers of amplifiers a frequent necessity that can be the cause of quality of service to drop below minimum acceptable levels Composite second order CSO and composite triple beat CTB are commonly used quality parameters that can be measured with the H30 to...

Page 19: ...urrent scan measurements You can see the datalogs using the remote control application 8 Voltmeter Hum H30 measures the voltage present at the RF input The HUM measurement indicates the variation in percentage of the video carrier amplitude of the TV signal This will help you diagnose those ground and power interference problems that may result from a defective power supply or faulty overloaded po...

Page 20: ... scan measurements You can see the datalogs using the remote control application If the cofficients exceed the limit there is a problem in the cable network 8 2 Setup Press to change Voltmeter Hum options Tuning Channel Frequency Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 9 Equalizer Displays a bar chart representing the equalizer...

Page 21: ...r graph representing found channels Color according to checkmarks Indicates that the scan is finished Press to save the plan Selected channel Change using 11 Ingress Scan Help identify reverse path problems before your customers are affected Poorly shielded coaxial cable and faulty terminations are important sources of ingress noise which can easily add up in the return due to the large number of ...

Page 22: ... Main window Below is a capture of a MPEG Info window with a brief explanation of its features 11 2 Setup Press to change Ingress Scan options Ingress frequencies 5 47 MHz 5 68 MHz 5 85 MHz 5 205 MHz Select the span of the graph Ref Level Select the reference level of the bar graph Reset Data Delete the max hold and min hold graph 12 Speed Test Opt 593211 or Ref 593180 Allows you to check your bas...

Page 23: ...elect the time interval elapsed between two consecutive measurements shots The H30 automatically performs all the measurements on the selected channel and saves them in memory Once you enter the function you must press the OK button to start measuring The H30 will measure and store all the measurements while the user do not leave the function 14 1 Main window Below is a capture of a LT Monitoring ...

Page 24: ...he selected carrier Bar graph showing the FM carriers found Selected channel Change using 16 Wi Fi Analyzer Opt 593213 or Ref 593180 Analyzes the W Fi band and automatically detects all the Wi Fi networks This feature automatically identifies the wifi networks as either their name and the power of the access point s signal There are two different screens to display the information The first screen...

Page 25: ...orts with attenuation Audio Carrier 4 5 MHz 5 5 MHz 6 0 MHz 6 5 MHz Test port Compensation Off 1 dB to 30 dB Bluetooth Option 593213 or Reference 593180 Allows to turn ON OFF the bluetooth connection If ON is selected it will appear a new line showing the MAC of the H30 Bluetooth interface and a bluettoth icon will be shown in the top right part of the screen When the equipment connects via blueto...

Page 26: ...erial number will be created automatically in the Path indicated bellow User Enter the user name to access the server using Password Enter the corresponding password using Energy Auto suspension As you can see in the image above the listo shows the name of the Wi Fi networks and indicates if the network is open or restricted as well as the protection access type To access to a restricted network y...

Page 27: ...u choose Auto all the parameters will be set automatically and you can see the values of the parameters in the same window 2 Firmware update Note When the equipment is connected to internet detects automatically if there ir a newer software version If so it will appear a message at the top of the screen in the main menu There are two ways to update the firmware of your H30 Directly from the meter ...

Page 28: ...rt HTML5 Google Chrome or Safari is recommended Open your browser in your PC or in your tablet Configure your network parameters see section 1 Network setup To run the remote control application you must copy the IP in the web browser bar and automatically will appear the main window of the 3 Press OK and the select On Press OK again to select the On option 4 Turn the meter off by pressing the Dev...

Page 29: ... to the main window Select other channel from the plan Select another profile and save the Datalog in the H30 Spectrum Sets the H30 in Spectrum mode and shows the current Spectrum main window Go back to the main window Select other channel from the plan Select another profile and save the Datalog in the H30 The user can move the marker to display the values of level and frequency at any point of t...

Page 30: ...ng functions Channel Info Constellation CTB CSO Volt Hum When the user selects one of theses ILOGs a window like the one shown bellow will open Datalogs In this section you can see all the measures saved in your H30 with the Save Datalog feature Go back to the main window List of Datalogs Allows to filter by date the Datalogs in the list and delete all the Datalogs User can filter by the Datalogs ...

Page 31: ... formats List of measurements with pass fail indicators Parameters of the channel and time and date of the measurement Channel on wich the measurements were made There are two views for the list of channels Table view and Icon view Above is shown theTable View and below the Icons View Icons view The Datalogs saved using the LT Monitoring system are appointed by default starting with LTM When the u...

Page 32: ...hannel plan data with the following fields separated by The name of the channel plan 10 characters maximum The channel plan ID 0 or blank for first free user plan and 50 n for updating user plan n From the second row onwards it will be used a row for each channel with the following fields in each row separated by The name of the channel 5 characters maximum The bandwidth in kHz The video offset in...

Page 33: ... Enter the new name and press Change User can add a new channel to a custom plan Quality Profiles In this section you can see all the quality profiles saved in your H30 Factory quality profiles are shown in dark gray and can not be edited Custom profiles are shown in light gray and can be edited Press Delete to confirm Enter the name frequency BW and video offset of the neww channel and press Add ...

Page 34: ...Go back to main window Allows tocreate a new quality profile List of quality profiles Select the quality profile and press Save User can change the name of the quality profile using the Edit name button User can save the changes using the Save Profile button User can also delete the quality profile using the Delete button Allows to edit the name of the profile save it or delete it Change the value...

Page 35: ... H30 configuration to from a file This is an easy way to have the same settings on all the meters of you fleet To do that configure your H30 with the selected parameters and then connect it to your computer select the About feature and click on the Export configuration button and enter a file name To download a configuration file to a meter click the Import Configuration button and select the file...

Page 36: ...ucts may damage the unit 4 Application Program Interface API Application Program Interface software is available using http to integrate data of H30 into applications that need it In its basic version that API allows you to set confi guration and retrieve measurement data from the H30 There is an extended paid API version opt 593212 that also provides access to more additio nal data Operation API ...

Page 37: ...or refund the purchase price of the Product s that has been determined by Televes to be defective in material or workmanship subject to the limits of this warranty C This warranty excludes any inoperability resulting from I use or installation that is not in strict compliance with the written instructions and specifications II any modification or alteration performed by any third party not authori...

Page 38: ...ontract negligence strict tort liability or otherwise or any other legal theory arising directly or indirectly from the sale use installation or failure of any product acquired by Purchaser from Televes H This limited warranty extends to the original Purchaser and cannot be assigned or transferred to any other party without the prior express written permission of Televes which permission Televes m...

Page 39: ...r 593103 Conforms to the following specifications FCC Part 15 Subpart B Section 15 107 e and section 15 109 g Supplementary Information This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operati...

Page 40: ...0 A11 2009 EN 61010 1 2010 EN 61326 1 2013 Santiago de Compostela 27 5 2014 José L Fernández Carnero Technical Director DECLARATION OF CONFORMITY Nº DCI140527132725 DECLARACIÓN DE CONFORMIDAD DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI DECLARATIE DE CONFORMITATE KONFORMITETSERKLÆRING CONFORMITEITSVERKLARING VASTAVUSE SERTIFIKAAT ATBILSTĪBAS...

Page 41: ......

Page 42: ...593101_593102_593103_593104_013_EN ...

Reviews: