background image

 

 

 

 

 

 

  

Write:

 

Read:

 

ID code

 

*0<ID code>#

 

*0#

 

Emergency call 1

 

*1<phone number>**<e.g. protocol>#

 

*1#

 

Emergency call 2

 

*2<phone number>**<e.g. protocol>#

 

*2#

 

Emergency call 3

 

*3<phone number>**<e.g. protocol>#

 

*3#

 

Technical call 

 

*4<phone number>**<e.g. protocol>#

 

*4#

 

Background call 

 

*5<phone number>**<Protocol>#

 

T: <**8>

 

ABP:         <**9>/<**1>

 

*5#

 

Password

 

*9<password>#

 

*9#

 

Alarm delay emergency 

button in cabin

 

**1*<delay in seconds (1

-

99)>#

 

Default: 5

 

**1#

 

Alarm delay 

 

In operation

 

**2*<delay in minutes (0

-

99)>#

 

Default: 0 = off

 

**2#

 

Alarm delay 

Door open

 

**3*<delay in minutes (0

-

99)>#

 

Default: 0 = off

 

**3#

 

Alarm delay 

Technical 

alarm

 

**4*<delay in seconds (1

-

99)>#

 

Default: 0 = off

 

**4#

 

Alarm delay 

External 

emergency button (PSB

-

30)”

 

**5*<delay in seconds (1

-

99)>#

 

Default: 0 = off

 

**5#

 

Alarm delay 

emergency 

button on the TSA5210

 

**6*<delay in seconds (1

-

99)>#

 

Default: 2

 

**6#

 

Activation of machine 

room handset

 

**0*152# (Timeout: 180 sec)

 

Default: 24 = off

 

**0#

 

Sound level

 

***0<level># Level options 1

-

9

 

Default: 9

 

***0#

 

Reading version no.

 

  

***#

 

Configuration table

 

Note:

 

It

s always a good idea to check the parameters with a readout or test call.

 

 

Remote programming

: Call the alarm and dial * # when the alarm responds with 2 beeps.

 

 

For help and guidance you are always welcome to contact

 

our service and support department at

 

Phone.: +45 46 300 720 or support@abp

-

teletech.com

 

Put the alarm in programming mode by holding down the setup button until the 3rd beep and 

press #

 