3
MPH200
series video encoders
WebUI user manual
MPH200 series video encoders mechanical connections
1. CVBS video input 1
, or optional
HD-SDI
video input (BNC female) and
indicator led.
2. CVBS video input 2
(BNC female) for 2-ch versions or
Video loop through port
for 1-ch versions and indicator led.
3. 16-pin screw terminal block
and T indicator led:
Data interfaces, EIA RS422/485 (data1), EIA RS232 (data 2) /manage-
ment interface (CLI) or general purpose serial port.
Contact closure interfaces (cc input 1, cc input 2, cc output)
4. Ethernet switch up-link interfaces
, 2 x socket for SFP module (GE,
see a product catalogue for supported models).
5. Ethernet switch local port interfaces
, 2 x 10/100/1000Base-T, RJ-45.
6. Audio interface
(10-pin screw terminal block).
7. Power supply
connector (2-pin screw terminal block, +12...28 VDC).
Reset button
: Device software reboot and hard/soft factory defaults
restoration (see section Factory reset).
Ground
: Device ground connection.
M
- (module/power led) LED indicator operation. This LED indicates power
status, factory reset, interface activity.
Factory reset
The factory reset can be done via
WebUI
,
CLI
, or using the pinhole
reset
button
on the front panel of device. There are two types of factory resets;
Soft factory and Hard factory reset. The Soft factory reset restores all,
except IP configuration to the default factory settings. The Hard factory
reset restores all settings to default factory settings.
Reset button
The reset pinhole is a button that resets the device to its original default
settings. To use this button, insert a stiff wire (such as a straightened paper
clip) into the pinhole. If you release the button immediately the device will
reboot with current settings. But if you hold the button you can restore the
default settings as following table shows.
Led
Colour
Mode
M
OFF / Dark
Power off
Yellow
Device starts up
Red
Device self-test failed
Green
Power on / Device is functional
Blinking Green
Device is being accessed from any interface.
Whenever device is accesed from WebUI, CLI or ONVIF
interface, led blinks 2s. During software update, LED will
blink throughout the firmware image transfer duration.
Led
Colour
Mode
M
6 x (short) green blinks at
boot time
Time window to select Soft factory reset.
If
reset button is released in this time window, soft factory
reset is selected.
2 x (short) red blinks
Soft factory reset shall be applied.
Wait until device has fully started (power led green).
24 x yellow blinks at boot time
(after the 6 green blinks)
Time window to select Hard factory reset.
If reset button is released in this time window, hard
factory reset is selected.
4 x (short) red blinks
Hard factory reset shall be applied.
Wait until device has fully started (power led green).
Note
! If pinhole button is not
released within time window,
operation will cancelled.
MPH241
signals.
MPH242
signals.
V
x2
CVBS
D
x2
A
x2
C
C
x2
E
x4
V
x1
CVBS or
HD-SDI
D
x2
A
x2
C
C
x2
E
x4