background image

Code Master

Model CWR-610E

OPERATING INSTRUCTIONS

Summary of Contents for CWR-610E

Page 1: ...Code Master Model CWR 610E OPERATING INSTRUCTIONS...

Page 2: ...RTTY 8 Reception of commercial station 9 CONNECTABLE PRINTERS 9 CONNECTION OF EXTERNAL TERMINALS OR CW HAND KEY 10 INTERNAL ADJUSTMENT CHANGEOVER ADJUSTMENT 10 DISPLAY SCREEN AND OPERATION STATUS DISP...

Page 3: ...W Mark demodulation system RTTY Mark demodulation single side system changeable to space demodu lation single side system by internal selection 4 Display outputs RF output CCIR European standard VHF c...

Page 4: ...ced codes Alphabet and numerals Speed 2 wpm to 30 wpm 9 Power source DC 12 V 700 mA usable in DC 10 V to 13 8 V 10 Overall dimensions 160 mm wide 205 mm deep 50 mm high 11 Weight 1 1 kg 12 Accessories...

Page 5: ...ing its operation is temporarily stopped When pressed again the operation is resumed from the interrupted point In Baudot mode when this switch is pressed the UOS is turned on and when pressed again i...

Page 6: ...all other function codes than CR NUL DEL are ignored Select a printer which incorporated buffer register for one line portion and automatically feeds line when this buffer register becomes full and a...

Page 7: ...e text is transferred to the second page from the first character Therefore to look for previous characters press the PAGE but ton 5 lines are repeated When the PAGE button is depressed the display re...

Page 8: ...high pitch side and MONITOR LED changes thus Goes out Flickers Lights Flickers Goes out continued light at mark middle between mark and space continued light at space Adjust to the first flickering po...

Page 9: ...e shift width Turn the dial of the receiver to adjust to the first flickering point RTTY exclusive use switch U O S Unshift on space After receiving a space signal the set automatically returns to the...

Page 10: ...100 Hz is possible by turning the VR 1 Feed a new frequency from AF IN terminal 2 Turn VR2 until the maximum output is delivered to TP2 on oscilloscope 3 Stop input from AF IN 4 Connect frequency cou...

Page 11: ...chart VIDEO OUT specification Composite video signals video normal modulation synchronous negative modulation 1 0 0 2 Vp p 75 ohms Initial start changeover of Baudot ASCII The set is initially set to...

Page 12: ...nal demodulator becomes a space demodulator The TTL IN is changed to mark H space L input When changing CLOCK terminal to TTL OUT terminal Cut the CUT land CLOCK and bridge the Bridge land TTL OUT wit...

Page 13: ...Code Morse Code Baudot Baudot Code LTR UOS OFF 45 BAUD LTR UOS OFF 45 BAUD BAUDOT Code ASCII ASCII CODE 110 BAUD 110 BAUD ASCII Code LTR case is changed to FIG case when switch is changed to FIG UOS O...

Page 14: ...ry speed When 30 blocks of five characters each are sent out the operation stops When the CP UOS switch is pressed again the display random characters are changed and the operation is started again at...

Page 15: ...characters are dis played The wpm display changes according to the selection from 2 to 30 CP ON display is changed to OFF and to ON again by selection of CP UOS switch Even if CP ON when MONI switch i...

Page 16: ...16 LAYOUT OF ADJUSTING VOLUMES AND SWITCHING SPOTS...

Page 17: ...CODES CW Display Code Display Code A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9 LineFeed period comma colon apostrophe dash BT AR quotation mark BK AS HH SX CL KA VE AA HR SK...