![TelePost LP-100 Manual Download Page 34](http://html.mh-extra.com/html/telepost/lp-100/lp-100_manual_1082123034.webp)
34
Specifications
(after factory calibration, preliminary data subject to change without notice)
Useful Power Range:
0.05W – 2500W
Power Accuracy:
<5% above 0.5W, <10% below 0.5W, +/- 1LSB (2% typical)
SWR Range:
1.00 to 9.99
SWR Accuracy:
<5% above 0.5W, <10% below 0.5W, +/- 1LSB (2%typical)
Directivity:
30+ dB, 160 – 6 meters (40 dB typical)
Insertion Loss
<0.05 dB, 1.8-50 mHz, (typical)
Impedance:
0-999.9 ohms Z, R and |X|, <5% (typical, 10-500 ohms)
Phase:
0-180.0 degrees, <5 degrees (<3 degrees typical, 10-170 degrees)
Frequency counter:
1 MHz to >100 MHz, +15 to +23 dBm sensitivity (~0.5% accuracy)
Power handling
1500W continuous duty, 2500W peak
Bargraph response
>90 Hz
Direct Inputs:
-15 to +33 dBm, 50 ohms, 0.1 to 650 MHz +0/-1.5 dB, 2W max
DC Power:
11-15 VDC @ 160 ma
Operating temp range:
0 to 50 degrees C
Clock:
40 mHz
Program memory:
64kB
Size:
Controller: 6.0" x 6.0" x 2.75" (5.08cm x 5.08cm x 6.99cm)
Coupler: 2.25” x 2.40” x 5.00” (5.72cm x 6.1cm x 12.7cm)
Weight:
3 pounds (1.36 kg)
CAL Table
Description
Fine Power
Gain Zero
Phase Zero
160m
80m
60m
40m
30m
20m
17m
15m
12m
10m
6m
Offset Trim
Master Power Trim
Gain Slope Trim
Phase Slope Trim
Lo/Hi Power Trim
Reference
Log the initial CAL constants for your LP-100 in this table. If you ever make changes, you can log additional constants in the spaces
provided.
Summary of Contents for LP-100
Page 28: ...28 Schematic Page 1 ...
Page 29: ...29 Schematic Page 2 Coupler Schematic ...
Page 36: ...36 Appendix A ...