Page 230
ATS
45 V.22bis EQM Threshold Value
S Register 45 is used to define the EQM (Eye Quality Monitor) value the modem will tolerate
before initiating an equaliser retrain sequence. This S Register applies to V.22bis only.
By setting this register with a low value, the modem will demand a high quality connection.
Setting a high value will allow the modem to operate on degraded lines without invoking retrains.
A value of zero will disable automatic EQM retraining for V.22bis.
☞
☞
☞
☞
☞
The value in this register should only be altered by people with previous EQM
experience. Changing the EQM value will affect the data throughput and
reliability of connections.
Default
98
Example
ATS45=5
Set EQM threshold to 5. If EQM level is equal to or greater than 5, the
modem will retrain the connection.
Range
0-255
Summary of Contents for Global Carrier
Page 1: ...Global Carrier 56 Modem User s Guide 0049 2200 001 Rev A...
Page 130: ...Page 130 Range 0 2...
Page 225: ...S Registers Page 225 See Also ATS105Voice Dead man Timer Range 0 255...
Page 252: ...Page 252 Standard RS 232 Examples...
Page 262: ...Page 262...
Page 289: ...Compliances Page 289...