Installation Procedure
2-4
2-4.3 FP310RAM-X Installation Procedure
2-4.3.1 Physical Installation
Use the following general procedure to install the FP310RAM-X in the prescribed location:
1.
Identify the exact location and position of the FP310RAM-X.
2.
Mark the 6 holes to be drilled in accordance with the information appearing in Figure 2-2,
and then drill using an appropriate drill tip for #8x32 screw.
3.
Thoroughly clean the surface on which the FP310RAM-X will be mounted.
4.
Insert a star washer and a flat washer on each of the 4 or 6 fastening bolts. Prepare
additional flat washers and star washers for insertion under the nuts (if 4 are used, then
place them on each of the corners).
5.
Place the FP310RAM-X on the mounting position, and fasten it with 4 or 6 bolts and nuts
using a torque screwdriver set to 0.35 – 0.53 lb/inch.
2-4.3.2 Cable Connections
Caution
The FP310RAM-X does not have an ON/OFF power switch, and will start
operating as soon as power is connected. Make sure that no power is supplied
until authorization to start operations is received.
1.
Identify the cables to be connected to the FP310RAM-X in accordance with the site
installation plan.
2.
Visually inspect the connectors for any signs of damage: do not attempt to connect if shell
or pins are bent. Thoroughly clean using a soft, clean brush to remove dirt and foreign
matter.
3.
Route each cable to the prescribed connector and mate the connectors. For each D-type
connector, secure the connection by tightening the two screws; use SMA wrench with
torque (see 2-4.1) to tighten RF connectors. Do not exert excessive force.
4.
Four cable tying points are provided around the FP310RAM-X: use cable ties to secure
the cables. To prevent stress caused by bending, make sure to leave enough slack.
2-4.3.3 Final Inspection
1.
Visually inspect the installation for proper execution, good workmanship and compliance
with the applicable practices and regulations.
2.
Check cable connections, and check their routes. Make sure that cables are securely routed
and fastened.
3.
Inspect the installation of the other system components in accordance with the applicable
instructions.
4.
Correct any problems detected during the inspection.
5.
After the inspection is successfully completed, refer to Chapter 3 to continue with the
preliminary configuration.
Warning
Do not apply power to the FP310RAM-X before explicit authorization is
received from the person in charge. The FP310RAM-X may start
transmitting as soon as power is applied, resulting in possible exposure of
personnel working near the antenna to microwave radiation.
The FP310RAM-X must not be allowed to transmit without being connected
to an antenna, or to other matched (50
) load.
Summary of Contents for FP310RAM-X
Page 21: ...PROPRIETARY...