Telegesis Compact Flash ETRX2CF v2 Product Manual Download Page 6

Telegesis 

 

 

 

TG-ETRX2CF-PM-01-200 

ETRX2CF v2 

Product Manual 

2.01 

 

 

©2008 Telegesis (UK) Ltd 

ETRX2CF Product Manual (Rev 2.01) 

Important  Note:

  With  hardware  handshaking  disabled  on  the  ETRX2  make  sure  I/O2  is  never 

defined  as  an  output  as  this  would  drive  against  the  CTS  input  and  cause  the  supply  current  to 
increase. 

5 Driver Installation and Operation 

The ETRX2CF wireless mesh networking  Compact

Flash™ card can be operated using Windows 

9x,  Windows  XP,Windows  2000,  Windows  Vista  on  any  PC,  or  the  Windows  Mobile  family  on  a 
PDA.  Finally the ETRX2CF can also be used with Linux. 

Host computer options 

1.  The ETRX2CF can be used with a Windows based PC or laptop which has a 

CF™ slot

2

 or by 

using  an  appropriate  adapter  to  connect  to  the  PCMCIA  slot.    After  installing  the  Windows 
driver  as  described  below,  the  standard  Telegesis  Terminal  Application  software  (or 
HyperTerminal)  can be used to control the ETRX2CF card.  Custom  application software can 
access the card

‟s AT-Command interface via a virtual COM port. 

2.  The  ETRX2CF  can  be  used  in  most  PDA  devices  running  Pocket  PC  and  Windows  Mobile, 

however we can only give guidance on the following units: HP iPAQ 5550 running Pocket PC 
and the HP iPAQ HX2490 running Windows Mobile 5.0.  In some instances the native drivers 
of the PDA are sufficient, but drivers for PocketPC, PocketPC 200x, Windows CE & CE.net on 
SH3,  SH4,  MIPS,  X86,  ARM,  StrongARM,  XScale  (and  other  ARM  cored  processors)  are 
available  from  our  website.    In  the  same  way  the  Telegesis  Terminal  for  Pocket  PC 
demonstration software can be downloaded from our website. 

To  run  Telegesis  Terminal  on  a  PDA,  the  PDA  needs  .NET  Compact  Framework  2.0,  which  is 
currently available at 

www.microsoft.com/downloads/details.aspx?FamilyID=9655156b-356b-4a2c-857c-
e62f50ae9a55&DisplayLang=en 

To read more about the ETRX2 wireless meshing module and its command line interface please 
read the corresponding documentation, which can be found at 

www.telegesis.com.

 

Please  Remember:

  In  order  to  conserve  power  some  operating  systems  power-down  the  entire 

card until the virtual COM port is opened.  Therefore, if you need to save power simply close the 
COM port and this will prevent the Compact

Flash™ card from consuming any power at all.  Also, 

please  note  that  after  opening  the  COM  port  a  short  delay  must  be  observed  before  trying  to 
communicate  with  the  ETRX2CF,  to  allow  the  unit  time  to  boot-up.   

Wait  until  it  writes  an  “OK” 

prompt before attempting to access it. 

There are three options for installing the 

CF™ card software: 

1.  Install Windows drivers on a laptop PC and use the conventional Telegesis Terminal software 

2.  Install drivers and Telegesis Terminal for PPC on a PDA using a PC with ActiveSync 

3.  Install drivers and Telegesis Terminal for PPC on a PDA manually 

In all cases, Telegesis Terminal or Telegesis Terminal for PPC is optional.  You can choose to only 
install the drivers and then use your own application software. 

                                                

2

 Fully functional 

CF™ host required.  Basic CF™ memory card readers are not sufficient. 

Summary of Contents for Compact Flash ETRX2CF v2

Page 1: ...Telegesis TG ETRX2CF PM 01 201 1 ETRX2CF v2 Product Manual 2 01 Telegesis 2008 Telegesis UK Ltd ETRX2CF Product Manual Rev 2 01 ETRX2CF COMPACT FLASH CARD PRODUCT MANUAL ...

Page 2: ...ERATION 6 5 1 Installing Windows drivers and Telegesis Terminal on a laptop PC 7 5 2 Installing drivers and Telegesis Terminal for PPC on a PDA using a PC with ActiveSync8 5 2 1 Drivers 8 5 2 2 Telegesis Terminal 9 5 3 Install drivers and Telegesis Terminal for PPC on a PDA manually 9 5 3 1 Drivers 9 5 3 2 Telegesis Terminal 9 5 4 Telegesis Terminal for PPC 9 6 CUSTOM APPLICATION DESIGN FOR MOBILE...

Page 3: ... Protocol over UART as described in section 6 of the Ember EM260 datasheet 1 1 Supported Operating Systems Windows 95 Windows 98 Windows XP Windows 2000 Windows Vista Pocket PC Windows Mobile 5 0 Linux Information on Linux can be obtained from Elan at www elandigitalsystems com support ccpfaq serialcardsinlinux php 1 2 Supported hardware There are many different PDAs available and it is not possib...

Page 4: ... ETRX2CF card contains an ETRX2 radio module details of which can be found in the ETRX2 or ETRX2 PA Product Manual as appropriate The AT command set is defined in the AT Commands Manual for R2xx or R3xx according to the firmware version in your CF card There is a general information on the setting up and maintenance of ZigBee mesh networks and examples of using the AT commands in the ETRXn User Gu...

Page 5: ...3 Operating ambient temperature range 20 25 70 C Table 2 Operating Conditions at 3 3V Please Note In order to conserve power some operating systems power down the entire card until the virtual COM port is opened Therefore if you need to save power simply close the COM port and this will prevent the Compact Flash card from consuming any power at all 4 ETRX2 I O Connectivity The I Os of the built in...

Page 6: ...er ARM cored processors are available from our website In the same way the Telegesis Terminal for Pocket PC demonstration software can be downloaded from our website To run Telegesis Terminal on a PDA the PDA needs NET Compact Framework 2 0 which is currently available at www microsoft com downloads details aspx FamilyID 9655156b 356b 4a2c 857c e62f50ae9a55 DisplayLang en To read more about the ET...

Page 7: ...u will be informed that the driver has not passed the Windows logo test When this happens simply press continue to finalise the driver installation The standard Telegesis Terminal Application software available from our web site will support the ETRX2CF card after the driver has been installed In order to find the identity number of the virtual COM port assigned to the card open the Device Manager...

Page 8: ... the CF card drivers Go to www telegesis com ZigBee CFV2 htm Then you can select Download Drivers for PDA only ActiveSync and download the driver installation file TGserialsetup_pocketpc exe Save TGserialsetup_pocketpc exe on your PC in order to execute it from there Do not insert the ETRX2CF card into your PDA yet it does not have the correct drivers connect the PDA to your PC running Microsoft A...

Page 9: ...is com ZigBee CFV2 htm Select Download Drivers for PDA only CAB and download the driver file xTRXnCF_CABs zip to your PC Unpack it transfer the appropriate cabinet file to the mobile device and execute it there It is a self extracting cabinet file 5 3 2 Telegesis Terminal Select Download Telegesis Terminal PPC for PDA CAB and download TelegesisTermPPC CAB Unpack it transfer it to your PDA and exec...

Page 10: ...rt up the following screen will be displayed on the Pocket PC With Telegesis Terminal for PPC V2 5 you must start with Settings Open To close the window select Settings Exit The preset buttons INFO executes the ATI command and gives details of the card s hardware and firmware JOIN joins the card to an existing PAN if one is available ...

Page 11: ...r setting up the PAN and sending data See the AT Command Manual for a full description of the various commands and registers The EUI64s menu When a command such as AT UCAST has been selected from the Commands menu the required EUI64 parameter to specify the destination node is appended to the command by selecting it from the EUI64s menu This menu becomes populated with up to 10 EUI64s at the time ...

Page 12: ...r of the Telegesis Terminal for Pocket PC software Exit closes the Terminal The Command window The full set of AT commands is available by typing them into the command window The Device List Holding down the PDA s stylus on an entry in the Device List below the preset buttons bar is the equivalent of right clicking with a PC s mouse It brings up a further menu of AT commands that are specific to t...

Page 13: ...sic 2007 sourcecode for the Telegesis Terminal for Pocket PC can be provided on request on an unsupported basis When developing a custom application for mobile devices please note that some operating systems require the virtual COM port to be closed before the device enters sleep mode and to be re opened upon wakeup This mechanism has to be handled by the application and is currently not supported...

Page 14: ... baud rate must also be altered by setting the correct S register Alternatively access to the SIF programming interface is possible by removing the antenna cover of the ETRX2CF wireless mesh networking Compact Flash card It is not permanently attached Via the SIF interface it is also possible to upgrade the card with the Ember EZSP interface 8 Custom Firmware Development If you intend to develop c...

Page 15: ...ETRX2 ETRX2HR Module with AT Style Command Interpreter Hirose U FL Antenna Connector No 2 4GHz Antenna No Harwin Connector ETRX2USB USB Stick AT Style Command Interpreter Integrated 2 4GHz Antenna Based on the ETRX2 Notes Customers PO s must state the Ordering Product Code There is no blank version of the ETRX2 Module available All Modules carry both the Ember Stack and the Telegesis AT style Comm...

Page 16: ...istered trademarks of their respective companies We reserve the right to make modifications and or improvements without prior notification All information is correct at time of issue Telegesis UK Ltd does not convey any license under its patent rights or assume any responsibility for the use of the described product 11 Contact Information Website www telegesis com E mail sales telegesis com Telege...

Reviews: