background image

User’s Guide MSA2 

 

Lift Intercom System (MSA2) 

 
These system provides an intercom connection between a telephone in the 
engine room an the lift emergency system NRT in the cabine. 
This is very helpful e.g. while maintenance or installation works. 
 
The MSA2 comes in a plastic housing with integrated power supply. 
There are several connectors in the lower part of the MSA2 (see picture 1), 
TAE-connectors for lift phone and telephone, selector switch and modular 
connector for telephone line. 
  

 

Connect your telephone line (public telephone line or PABX) with either 
modular connector or the 2-pin connector right of them. 

 

 

Connect your engine room telephone set with connector TAE1. 

 

 

Connect the lift emergency call telephone NRT with either TAE2 or with 
the 2-pin connector left of them. 

 

 

The selector switch is if the communication time between engine room 
telephone and lift phone is restricted to 30 minutes or not. 
If switch is ON, communication time is restricted to 30 minutes. 
After that time a emergency call is possible, even if the engine room 
telephone is not on-hook. 
A renewed connection between engine room telephone to lift phone 
may established by on-hook and off-hook of the engine room 
telephone. 
If switch is OFF, there is no communication time limit, which may cause 
an always busy line by the MSA2.

 

Summary of Contents for MSA 2

Page 1: ...User s Guide MSA2 User s Guide MSA2...

Page 2: ...lektronik GmbH Read the following precautions before you install the intercom system IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should f...

Page 3: ...ther modular connector or the 2 pin connector right of them Connect your engine room telephone set with connector TAE1 Connect the lift emergency call telephone NRT with either TAE2 or with the 2 pin...

Page 4: ...front cover The MSA2 were designed for wall mounting and should be mounted near the lift emergency phone connector in the lift engine room A standard dial tone telephone is used as engine room teleph...

Page 5: ...PSTN PABX Engine Room lift cable NRT cabine 2 TAE2 TAE1 MSA2 connector 230V Modular jack Time Limit off on User s Guide MSA2...

Page 6: ...time equals the communication time set in the NRT If the communication time expires the NRT disconnects On hook your engine room telephone A new intercom connection may be established again as describ...

Page 7: ...ly beep NRT connects to line 0000 enter access code immediately after beep tone beep NRT confirms right access code and is now in programming mode 607 4 tone melody NRT enters voice connection 1 selec...

Page 8: ...Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 15 C to 50 C 5 F to 122 F Relative Humidity 5 75 RH noncondensing Ventilation Air around the unit must be free of dust chemicals or...

Page 9: ...t Liability Law All products from our product range may only be used for the indicated purpose In case of doubt you should consult a competent expert or our service department All energized products e...

Page 10: ...User s Guide MSA2 Date Teleg rtner Elektronik GmbH 03 rd of March 2006 74564 Crailsheim Germany Internet e mail www telegaertner elektronik de info telegaertner elektronik de...

Reviews: