Sprint V/V3/V4/V5
Quickstart guide
Set date & time:
use the soft keys
–
and
+
to change units of date and time
and
è
to select hours, minutes, day, month and year. Press ESC to save.
Edit report header:
use the soft keys
é
and
ê
to select header text one or two
and
–+
to edit text. Use the and keys to scroll through character lists
and character values. Press
è
to move on to the next letter in the header
text. Press ON/OFF/ENTER to delete all characters to the right. Press
è
to
move the cursor to the end of the text and
þ
to accept change and return
to Edit report header screen. Press ESC to exit edit without saving changes.
Change password:
press the soft key
–+
to edit password. Use the and
keys to scroll through character lists and character values. Press
è
to move
on to the next letter in the password. Press
è
to move the cursor to the
end of the text and
þ
to accept change and return to Password screen.
Press ENTER to store the change.
Print Cal Due:
Enable or disable printing of calibration due on reports.
Flue CO Alarm:
During flue gas analysis, a carbon monoxide alarm can be set
to activate at 300ppm of CO or disabled.
Retrieving stored logs
From the
Main
Menu
select
Stored logs
and one of the following options:
Select a log:
use the soft keys to scroll and select log.
Find a log by number:
use the soft keys to scroll up and down the numbered
logs database.
Delete all logs:
this option will delete all stored logs.
Press accept
þ
'Are you
sure?' to clear logs or press ESC to cancel.
Switch off
Turn off unit in clean air and ensure any gas is purged from sensors. Press and
hold the ON/OFF/ENTER button for approximately two seconds. The power off
screen will be displayed and the pump will run to purge the sensors. The pump
will run for up to 30 or 40 seconds to purge unit if gas is present. Sprint will
normally switch off in 10 seconds. Press the ESC key to cancel the switch off
sequence.
Charging battery
Plug the supplied charger into the charger socket. The batteries will recharge
in six hours from flat. You may leave the unit on charge for longer periods, e.g.
overnight, without damaging the unit. A fully charged unit will give up to nine
hours of operation. A shorter charge time can be applied, such as 1/2 hour, to
allow a more limited length of operation.