USING THE IDF SERIES

CONTROLS  AND OPERATIONS

CONTROLS AND OPERATIONS

P

OWER

:

Press the PWR/Light, switch on the front panel of the IDF unit to turn the

unit on, a second push will turn the backlight on. Push a third time to turn the
backlight off. A long depression of the PWR/Light switch will power the IDF off.

S

ENSITIVITY

:

The logarithmic nature of the Sensitivity Control allows improved

fine tuning of the unit‘s gain. From the zero setting to the 32 setting of the
sensitivity key the gain is increased from zero to full. At the 10 Position the
gain is approximately 20% with full gain being achieved at the 32 setting as
shown on the display.

R

ANGE

:

The unit powers up on the 40' RANGE and can be changed to the

80' or 120' RANGES by depressing the RANGE button. The selected RANGE
will be displayed in the center of the 

IDF

. A shallow RANGE selection may not

display a bottom return.

S

UPPRESSION

:

The unit will power up without S

UPPRESSION

. To add S

UPPRESSION

,

press the S

UPPRESSION

key. Pressing the key again will eliminate S

UPPRESSION

.

S

UPPRESSION

provides an advanced level of control over the amount of visi-

ble detail on the unit. You can choose the setting that works best for your
style of use.

With S

UPPRESSION

set to 

OFF

, the 

IDF

displays increased detail, showing more

thermoclines, structure, fish and even your bait when it falls within the sonar
cone. However, this extreme sensitivity requires you to optimize the installation
of your unit and transducer so that “noise” generated by a moving boat is not
picked up by the fishfinder.

With S

UPPRESSION

set to 

ON

, excessive clutter often caused by interference from

other fishfinders, your boat‘s engine, or from noise generated by the hull at
high speeds is reduced in the display. This provides a cleaner image on the dis-
play in most cases. Adjust SENS (S

ENSITIVITY

) for best display at various speeds,

from trolling on up to your boat's maximum speed with RealTime™ Sonar.

B

ACKLIGHT

ON:

To turn the display BACKLIGHT on press the Power Light

switch once. To Turn the Backlight off, press the Power Backlight Switch momen-
tarily. Continued Depression will turn the Unit off.

Summary of Contents for TFXIDF

Page 1: ...TFXIDF Operations Manual...

Page 2: ...f your Teleflex Sonar product Also to register your purchase and help us learn more about you please fill out the included warranty registration card WARNING This device should not be used as a naviga...

Page 3: ...feet outer scale 0 80 feet outer scale x 2 0 120 feet inner scale Pulse Length 0 40 feet 100 sec microseconds 0 80 feet 200 sec 0 120 feet 300 sec Frequency 200 kHz Temperature 32 to 99 F Output power...

Page 4: ...backlight for nighttime use 140 Segment RealTime 3 Level Grayscale Display Noise Suppression Button Suppression ON Increase Sensitivity from 0 to 32 in logarithmic steps Decrease Sensitivity Sensitiv...

Page 5: ...ress the SUPPRESSION key Pressing the key again will eliminate SUPPRESSION SUPPRESSION provides an advanced level of control over the amount of visi ble detail on the unit You can choose the setting t...

Page 6: ...ontent weeds brush steep slopes and fish are readily attainable The Zero mark will be on at all times This mark represents the start of the Sonar Depth scale which is relative to the placement of your...

Page 7: ...ature to prevent wrap on all scales to assist in differentiating bottom second echo and fish Soft Bottom A soft bottom is displayed on the IDF as a gray return Soft bottoms absorb the sound waves and...

Page 8: ...the abil ity to identify targets laying on or very close to the bottom This illustration shows a fish one segment from a hard bottom Most other electronic units would not read this fish since they of...

Page 9: ...n or out of the transducer cone while another fish is directly under the transducer cone near 17 Fish at 17 and either baitfish or larger fish at edge of cone at 16 SUPPRESSION Dead Zone Any and all s...

Page 10: ...depths Trees of course will appear station ary Another way to identify fish is to reduce the sensitivity and grayscale to minimize the number of segments Dark segments may be fish Structure such as t...

Page 11: ...n boat is not moving and at slow speeds but random flashes occur at higher speed Unit turned on but unit displays zero at all times Night light operates but no bottom display Unit turned on but unit d...

Page 12: ...ERAL WARRANTY ACT EFFECTIVE JULY 4 1975 SERVICE POLICY This Service Policy is valid in the United States only This applies to Teleflex Sonar units returned to our factory in Eufaula Alabama and is sub...

Page 13: ...ervice charge will be assessed for each repair physical damage and missing parts are not includ ed Please call our Customer Support Department to verify the service charge for your unit If shipping ch...

Page 14: ......

Page 15: ......

Page 16: ...A Division of Teleflex Marine...

Reviews: