FCC STATEMENT This device complies with Part 15 of the FCC rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and (2) This device must 
accept any interference received, including interference that may cause undesired operation. NOTE: 
This equipment has been tested and found to comply with time limits for a Class B digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can radiate radio 
interference energy and, if not installed and used in accordance with the instructions, may case 
harmful interference to radio communications. However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: A. Re-orient or 
relocate the receiving antenna. B. Increase the separation between the equipment and the receiver. C. 
Connect the equipment into an outlet or on a circuit different from that to which the receiver is 
connected. D. Consult the dealer or an experienced radio/TV technician for help. 

 

Charger Settings 

 

The charger automatically retains the settings selected at the start of a charge cycle and returns 
to them at the end of a charge cycle and at the next power on.   

 

Software Version 

The TDMC only has one software configuration.  Software cannot be updated by the user and does 
not need to be updated.  Software may change due to production variation or component 

differences.  A charger’s software version can be determined in the field by following these steps:

 

1.

 

Power unit off. 

2.

 

Press and hold any of the four buttons A-D 

3.

 

Power unit on while continuing to hold the button 

 

 

Summary of Contents for TDMC+

Page 1: ...rights reserved TDMC Teledyne Dual Mode 12 and 24 VDC Lead Acid Battery Charger Redlands CA 92374 1 800 456 0070 1 909 793 3131 support teledynebattery com Product Name TDMC Part Number TDMC 01 Docume...

Page 2: ...e 3 Product Description 4 Precautions and Warnings 5 Batteries 5 Location 5 Grounding and AC Power Cord 5 DC Output Connection 6 Charger 6 Personal Precautions 6 Charger Operation 7 Organization of th...

Page 3: ...oltage mode User selects charger voltage for 12V or 24V operation as appropriate for the battery to be charged by pressing the button in Screen Section A Caution If a 12V battery is charged with a 24V...

Page 4: ...Teledyne Battery Products TDMC is a battery charger for 12V and 24V lead acid batteries It offers two microprocessor controlled precision charging method a three stage charging method for normally dis...

Page 5: ...smooth even uncluttered surface Allow adequate airflow around the unit during charging to prevent overheating Maintain minimum 3 7cm distance to wall Do not use the charger on a soft carpeted upholste...

Page 6: ...C connection Make sure that the cable s terminals are free of any corrosion Charger Never operate a charger that has been damaged in any way including impact shock or excessive exposure to moisture pl...

Page 7: ...g cable to the Positive terminal on the battery Connect the Negative Black charging cable to the Negative terminal on the battery Reversing these connections results in the charger displaying a Revers...

Page 8: ...lete in the allotted time See charging Method details for allotted times Note in most Error conditions Selection Items A B C and D will vanish and the charger will not allow further operation until po...

Page 9: ...ging Charger is idle Red Stopped on Error Red Green Charging Green Charge Complete Connection Red Battery is reverse polarity Red Green Battery not detected Green Battery is connected correctly Charge...

Page 10: ...For Normally Discharged Lead Acid Battery Charge Method select End at 5A in Screen Section E With this selection the charger will follow the three stage charge mode recommended for use with all normal...

Page 11: ...dition The Deeply Discharged or Sulphated Lead Acid Battery Charge Method ending condition is based on time The time should be based upon the battery capacity in amp hours and the desired charging cur...

Page 12: ...the button in Screen Section F to start the charge cycle Details of the Two Stage Charge Mode 1 Stage 1 Constant Current Bulk Charge With the battery in a discharged state charging initiates in consta...

Page 13: ...of Stage 1 2 10 80 hours selectable Max Absorption Voltage 15 0V 100mV 30 0V 100mV Unit Specifications Electrical Input Voltage 85 VAC 270 VAC 50 60 Hz Max Power 250 Watts Configuration Line neutral c...

Page 14: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 15: ...battery 5 Verify DMM matches voltage on screen 5V 6 Press Pause 7 Verify DMM matches voltage on screen 2V 8 Set DMM to current mode connect DMM in series with battery 10A mode 9 Resume charge press Go...