Teledyne T3AFG30 Quick Start Manual Download Page 17

15

AUSTRALIA & NEW ZEALAND DECLARATION OF CONFORMITY – EMC

The instrument complies with the EMC provision of the Radio Communications Act per the
following standards, in accordance with requirements imposed by Australian Communication and
Media Authority (ACMA):
AS/NZS CISPR 11:2015 Radiated and Conducted Emissions, Group 1, Class A.

Australia / New Zealand Contacts:*

RS Components Pty Ltd.

RS Components Ltd.

Suite 326 The Parade West

Units 30 & 31 Warehouse World

Kent Town, South Australia 5067

761 Great South Road
Penrose, Auckland, New Zealand

* Visit teledynelecroy.com/support/contact for the latest contact information.

Safety Compliance
EC DECLARATION OF CONFORMITY – LOW VOLTAGE

The instrument meets intent of EC Directive 2014/35/EU for Product Safety. Compliance was
demonstrated to the following specifications as listed in the Official Journal of the European
Communities:
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and
laboratory use –
Part 1: General requirements
EN 61010-2:030:2010 Safety requirements for electrical equipment for measurement, control,
and laboratory use –
Part 2-030: Particular requirements for testing and measuring circuits

The design of the instrument has been verified to conform to the following limits put forth by these
standards:
• Mains Supply Connector: Overvoltage Category II, instrument intended to be supplied from the
building wiring at utilization points (socket outlets and similar).
• Measuring Circuit Terminals: No rated measurement category. Terminals not intended to be
connected directly to the mains supply.
• Unit: Pollution Degree 2, operating environment where normally only dry, non-conductive
pollution occurs. Temporary conductivity caused by condensation should be expected.

Environmental Compliance

END-OF-LIFE HANDLING

The instrument is marked with this symbol to indicate that it complies with the
applicable European Union requirements of Directives 2012/19/EU and 2006/66/EC
on Waste Electrical and Electronic Equipment (WEEE) and Batteries.
The instrument is subject to disposal and recycling regulations that vary by country
and region. Many countries prohibit the disposal of waste electronic equipment in

standard waste receptacles. For more information about proper disposal and recycling of your
Teledyne LeCroy product, please visit teledynelecroy.com/recycle.

Summary of Contents for T3AFG30

Page 1: ...T3AFG30 T3AFG60 Function Arbitrary Waveform Generators Quick Start Guide ...

Page 2: ...te and distribute Teledyne LeCroy Inc documentation for internal educational purposes only Resale or unauthorized duplication of Teledyne LeCroy publications is strictly prohibited Teledyne Test Tools is a trademark of Teledyne LeCroy Inc Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earlier versio...

Page 3: ...he BNC or the instrument may be damaged Observe all terminal ratings and signs on the instrument to avoid fire or electric shock Before connecting to the instrument read the manual to understand the input output ratings Do not operate with suspected failures If you suspect that the instrument is damaged contact the Teledyne LeCroy service department immediately Do not operate in wet damp condition...

Page 4: ...minal ON Standby Power Alternating Current Operating Environment Temperature 0 C to 40 C Relative Humidity 5 to 90 RH at 30 C Altitude 3048 m at 30 C Use indoors only Pollution degree 2 Use in an operating environment where normally only dry non conductive pollution occurs Temporary conductivity caused by condensation should be expected AC Power Input Voltage Frequency 100 120 V at 400 Hz or 100 2...

Page 5: ...Handle Adjustment Users can adjust the handle to the required position by pulling the mounting points outward and adjusting the handle position Handle Adjustment Horizontal Position Carrying Position 3 ...

Page 6: ...ort Used to read waveforms or status files from a USB drive or save current instrument status to a USB drive Firmware can be updated through the USB port The waveform generator supports a FAT formatted USB drive 3 TFT Display The waveform generator has a 4 3 inch TFT color LCD display which can display the current function menu parameter settings system state and help 4 Numeric Keypad Consists of ...

Page 7: ... backlight turns on and the connector outputs waveforms according to the current configuration of CH1 CH2 Control Port Output Button The Output button on the right is used to turn on off CH2 output The nominal output impedance of the BNC connector is 50 Ω When pressing Output the backlight turns on and the connector outputs waveforms according to the current configuration of CH2 CAUTION Over volta...

Page 8: ...klight will turn on when this function is selected Burst Burst Used to generate burst signals of Sine Square Ramp Noise and Arbitrary It supports NCycle Gated and Infinite burst modes Noise can only be used to generate gated burst It supports Internal External and Manual trigger sources The corresponding backlight will turn on when this function is selected Parameter Parameter Setting Used to swit...

Page 9: ...an be adjusted Waveforms Square Provides square wave output which ranges from 1 μHz to 30 MHz or 60 MHz depending on the model The Waveforms backlight will turn on when this function is selected The square wave Frequency Period Amplitude High level Offset Low level Phase and Duty can be adjusted Waveforms Ramp Provides ramp waveform output which ranges from 1 μHz to 500 kHz The Waveforms backlight...

Page 10: ...on when this function is selected Supports two output modes DDS and TrueArb Built in waveforms include Cardiac Gauspuls ExpRise and ExpFall etc In addition it can output waveforms stored on a USB drive Users can edit arbitrary waveforms through PC software and download them to the instrument Arbitrary waveforms can be adjusted for Frequency Period Amplitude High level Offset Low level and Phase 11...

Page 11: ...ut port When synchronization is on the port can output a CMOS signal with the same frequency as basic waveforms except Noise and DC arbitrary waveforms and modulated waveforms except external modulation AM DSB AM FM PM ASK FSK PSK and PWM external modulation signal input port 3 10 MHz Clock Input Output Port BNC connector The function of this connector is determined by the type of the clock source...

Page 12: ...400 Hz 6 USB Device Used when connecting the instrument to an external computer to allow waveform editing and remote control 7 LAN Interface Through this interface the generator can be connected to your computer or network for remote control An integrated testing system may be built as the generator conforms to the VXI 11 class standard of LAN based instrument control 10 ...

Page 13: ...h screen is clicked 2 Channel Status Bar Indicates the selected status and output configuration of the channels This area of the screen is switch to the corresponding channel when the channel select key is pressed The display will then show the channels and the shortcut menus for the function keys Mod Sweep Burst Parameter Utility and Store Recall 3 Basic Waveform Parameters Area Shows the current...

Page 14: ...rresponding channel output control port you can turn on off the current channel 5 LAN Status Icon The generator will show different prompt messages based on the current network status This diagram indicates LAN connection is successful This diagram indicates there is no LAN connection or LAN connection is unsuccessful 6 Menu Touch here for the menu corresponding to the displayed function For examp...

Page 15: ...g multiple instruments 9 Restoring factory settings 10 Technical support 13 Introduction to EasyWaveX The T3AFG30 and T3AFG60 series includes arbitrary waveform editing software called EasyWaveX This software is a platform for easily creating editing and transferring waveforms to the generator It provides 11 standard waveforms such as Sine Square Ramp Pulse Noise and DC which meets most engineers ...

Page 16: ... 1000 MHz 3 V m 1400 MHz 2 GHz 1 V m 2 GHz 2 7 GHz EN 61000 4 4 2012 Electrical Fast Transient Burst 1 kV on power supply lines 0 5 kV on I O signal data and control lines 4 EN 61000 4 5 2014 A1 2017 Power Line Surge 1 kV AC Mains L N L PE N PE 4 EN 61000 4 6 2014 RF Conducted Electromagnetic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 A1 2017 Mains Dips and Interruptions 0 1 cycle 70 25 cycle...

Page 17: ...or measurement control and laboratory use Part 2 030 Particular requirements for testing and measuring circuits The design of the instrument has been verified to conform to the following limits put forth by these standards Mains Supply Connector Overvoltage Category II instrument intended to be supplied from the building wiring at utilization points socket outlets and similar Measuring Circuit Ter...

Page 18: ... hazardous substances contained in the instrument are disclosed in accordance with the standards SJ T 11364 2014 Marking for the restricted use of hazardous substances in electronic and electrical products and GB T 26572 2011 Requirements on concentration limits for certain restricted substances in electrical and electronic products The instrument is marked with an appropriate Environmental Friend...

Page 19: ...17 ...

Page 20: ... founding in 1964 we have focused on crea ng products that improve produc vity by helping engineers resolve design issues faster and more effec vely Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high performance systems and to validate electronic designs in order to improve me to market The Teledyne Test Tools brand ex...

Reviews: