214578 REV A  ECO 18422 

GaN PowerMAX 

Second Generation GaN 

Modular N+1 Phase Combined System 

Spare Module/Chassis Part Number Configuration 

Band 

C-Band 

CC 

X-Band 

XX 

Ku-Band 

KU 

S-Band 

SS 

Module Configuration 

SSPA Module 

Single SSPA Chassis 

Chassis Power Level (in Watts)  

 

Band 

Output Power 

S-Band 

050, 100, 200, 300,  
400, 500, 600, 800, 

1000 (10K) 

C-Band 

050, 100, 200, 300, 

400, 650 or 800 

X-Band 

300, 400, 650 or 800 

Ku-Band 

050, 080, 100, 150, 

200, 300, 400 or 500 

Use and Disclosure of Data 

 
The items described herein are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the 
ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any per-
son other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first 
obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations. 
 

Proprietary and Confidential 

 
The information contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduction in part or as a whole without the 
written permission of Teledyne Paradise Datacom is prohibited. 
 
Specifications are subject to change without notice. 

The

 

SSPA

 

Module

 

(M)

 

is

 

the

 

removable

 

assembly

 

that

 

is

 

inserted

 

into

 

a

 

system’s

 

exis ng

 

rack

 

mountable

 

chassis.

 

This

 

can

 

be

 

done

 

without

 

taking

 

the

 

system

 

o

ff‐

line.

 

 

The

 

Single

 

SSPA

 

Chassis

 

(C)

 

is

 

the

 

rack

mountable

 

chassis,

 

with

 

the

 

SSPA

 

Module

 

assembly

 

installed.

 

Installing

 

a

 

new

 

chassis

 

requires

 

a

 

system

 

shut

down.

 

GaN Designation 

G  GaN Technology 

Frequency Sub Band

 

S-Band 

2.02 to 2.12 GHz 

2.20 to 2.30 GHz 

C-Band 

5.850 to 6.425 GHz 

5.850 to 6.725 GHz 

X-Band  

7.900 to 8.400 GHz 

7.500 to 8.500 GHz 

14.00 to 14.50 GHz 

13.75 to 14.50 GHz 

Ku-Band  

1.75 to 2.12 GHz 

H  P  A   

 

 

 

 

 

  X  X  X  X  X  G  2 

2nd Generation 

Summary of Contents for GaN PowerMAX

Page 1: ...assis operation Ethernet Port with UDP SNMP and internal web browser capability Legacy RS 485 M C Accurate Output Power Measurement Reflected Power Monitor RF Output Sample Port RF Gain Adjustment 42...

Page 2: ...ing efficiency is optimized within the operating frequency band System Output Power and Configurations Because the system power combining is purely passive and no switching is used there is never an i...

Page 3: ...h an array of mod ular hot swap power supply chassis Power is distributed from the power supplies to the SSPA modules via a bus rail assembly Each of the power supply modules has its own single phase...

Page 4: ...n and there are no mechanical switches involved that would create an interruption of service With parallel system architectures the amplifier output power capability and gain will change as the number...

Page 5: ...hot swappable active assemblies The units can be configured with a wide variety of SSPA frequency bands and power levels and can be fitted with the following SSPA modules S Band 50W 100W 200W 300W 40...

Page 6: ...0 23 400 61 2 1318 58 2 661 800 W 64 5 2818 61 5 1413 16 000 14 000 35000 29400 62 1 1622 59 1 813 Heat Load Btu hr 4 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 4 Modul...

Page 7: ...9 0 794 Heat Load Btu hr 4 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 4 Module RF Output Power AC Input Power W 3 Module Redundant RF Output Power Psat typical dBm W P...

Page 8: ...880 65 2 3311 62 2 1660 800 W 67 3 5370 64 3 2692 32 000 28 000 69 755 58 875 66 1 4074 63 1 2042 Heat Load Btu hr 8 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 8 Module...

Page 9: ...95 Heat Load Btu hr 8 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 8 Module RF Output Power AC Input Power W 7 Module Redundant RF Output Power Psat typical dBm W PLinea...

Page 10: ...7 68 5 7079 65 5 3548 800 W 70 0 10000 67 0 5012 64 000 56 000 139 511 117 751 69 4 8710 66 4 4365 Heat Load Btu hr 16 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 16 Mod...

Page 11: ...Load Btu hr 16 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 16 Module RF Output Power AC Input Power W 15 Module Redundant RF Output Power Psat typical dBm W PLinear mi...

Page 12: ...ar Parabolic Ripple 0 01 0 003 1 0 ns MHz ns MHz2 ns p p Noise Output TX Band RX Band C Band without filter RX Band X Band without filter RX Band X Band with filter RX Band Ku Band without filter RX B...

Page 13: ...1 592 13 76 25 1936 75 2RU FILLER 4RU FILLER 2RU FILLER 1RU PS2 1RU VENT 1RU PS1 1RU VENT 3RU SSPA 1 3RU SSPA 2 3RU SSPA 3 3RU SSPA 4 1RU RF DIST 3RU SSPA 5 3RU SSPA 6 3RU SSPA 7 3RU SSPA 8 3RU FILLER...

Page 14: ...WAY SYSTEM ONLY OMIT FOR 4 WAY 61 05 1550 8 59 18 1503 2 Cabinet Exhaust Option The PowerMAX system is available with an optional cabinet exhaust system which includes a rear door for the cabinet and...

Page 15: ...iginal form or after being incorporated into other items without first obtaining approval from the U S government or as otherwise authorized by U S law and regulations Proprietary and Confidential The...

Page 16: ...320 W 562 W 1000 W 100 S 638 W 1100 W 2000 W 200 S 970 W 1700 W 3000 W 300 S 1280 W 2240 W 4000 W 400 S 1600 W 2800 W 5000 W 500 S 2000 W 3500 W 6300 W 600 S 2500 W 4500 W 7800 W 800 S 3200 W 5600 W...