Teledyne GaN PowerMAX Manual Download Page 10

PAGE 10 OF 16 

214578 REV A  ECO 18422 

GaN PowerMAX 

Second Generation GaN 

Modular N+1 Phase Combined System 

16 Module C-Band PowerMAX System Power Specifications 

SSPA  

Module 

Power  

Level  

16 Module  

RF Output Power 

AC Input  

Power (W) 

15 Module Redundant  

RF Output Power 

P

sat

, typical 

dBm (W) 

P

Linear

, min. 

dBm (W) 

P

sat 

/ P

Linear

 

P

sat 

/ P

Linear

 

P

sat

, typical 

dBm (W) 

P

Linear

, min. 

dBm (W) 

50 W 

58.0 (631) 

55.0 (316) 

8,000/6,400 

20,000/15,000 

57.2 (525) 

54.2 (263) 

100 W 

61.0 (1259) 

58.0 (631) 

9,600/8,000 

21,760/17,408 

60.4 (1096) 

57.4 (550) 

150 W 

62.8 (1905) 

59.8 (955) 

16,000/12,800 

37,000/28,000 

62.2 (1660) 

59.2 (832) 

200 W 

64.0 (2512) 

61.0 (1259) 

17,600/14,080 

39,189/29,614 

63.4 (2188) 

60.4 (1096) 

300 W 

65.8 (3802) 

62.8 (1905) 

24,000/20,800 

52,000/43,400 

65.2 (3311) 

62.2 (1660) 

400 W 

67.0 (5012) 

64.0 (2512) 

28,800/25,600 

61,000/52,300 

66.4 (4365) 

63.4 (2188) 

650 W 

69.1 (8128) 

66.1 (4074) 

52,800/44,800 

115,517/93,757 

68.5 (7079) 

65.5 (3548) 

800 W 

70.0 (10000) 

67.0 (5012) 

64,000/56,000 

139,511/117,751 

69.4 (8710) 

66.4 (4365) 

Heat Load  

(Btu/hr) 

16 Module S-Band PowerMAX System Power Specifications 

SSPA  

Module 

Power  

Level  

16 Module  

RF Output Power 

AC Input  

Power (W) 

15 Module Redundant  

RF Output Power 

P

sat

, typical 

dBm (W) 

P

Linear

, min. 

dBm (W) 

P

sat 

/ P

Linear

 

P

sat 

/ P

Linear

 

P

sat

, typical 

dBm (W) 

P

Linear

, min. 

dBm (W) 

50 W 

57.5 (556) 

54.5 (279) 

6,400/4,800 

14,960/11,800 

56.9 (484) 

53.9 (243) 

100 W 

60.0 (1000) 

57.0 (500) 

8,000/6,400 

17,400/15,200 

59.4 (861) 

56.4 (432) 

200 W 

63.0 (2000) 

60.0 (1000) 

12,800/11,200 

36,000/34,600 

62.4 (1700) 

59.4 (861) 

300 W 

64.8 (3000) 

61.8 (1500) 

20,800/16,000 

43,433/36,949 

64.2 (2600) 

61.2 (1300) 

400 W 

66.0 (4000) 

63.0 (2000) 

25,600/20,800 

52,300/47,900 

65.4 (3400) 

62.4 (1700) 

500 W 

67.0 (5000) 

64.0 (2500) 

28,800/24,000 

56,500/54,000 

66.4 (4300) 

63.4 (2100) 

600 W 

68.0 (6300) 

65.0 (3100) 

35,200/27,200 

68,285/60,254 

67.4 (5400) 

64.4 (2700) 

800 W 

69.0 (7800) 

66.0 (4000) 

40,000/32,000 

74,200/69,750 

68.4 (6800) 

65.4 (3400) 

Heat Load (Btu/

hr) 

1000 W 

70.0 (10000) 

67.0 (5000) 

64,000/56,000  130,000/129,000 

69.4 (8600) 

66.4 (4300) 

Summary of Contents for GaN PowerMAX

Page 1: ...assis operation Ethernet Port with UDP SNMP and internal web browser capability Legacy RS 485 M C Accurate Output Power Measurement Reflected Power Monitor RF Output Sample Port RF Gain Adjustment 42...

Page 2: ...ing efficiency is optimized within the operating frequency band System Output Power and Configurations Because the system power combining is purely passive and no switching is used there is never an i...

Page 3: ...h an array of mod ular hot swap power supply chassis Power is distributed from the power supplies to the SSPA modules via a bus rail assembly Each of the power supply modules has its own single phase...

Page 4: ...n and there are no mechanical switches involved that would create an interruption of service With parallel system architectures the amplifier output power capability and gain will change as the number...

Page 5: ...hot swappable active assemblies The units can be configured with a wide variety of SSPA frequency bands and power levels and can be fitted with the following SSPA modules S Band 50W 100W 200W 300W 40...

Page 6: ...0 23 400 61 2 1318 58 2 661 800 W 64 5 2818 61 5 1413 16 000 14 000 35000 29400 62 1 1622 59 1 813 Heat Load Btu hr 4 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 4 Modul...

Page 7: ...9 0 794 Heat Load Btu hr 4 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 4 Module RF Output Power AC Input Power W 3 Module Redundant RF Output Power Psat typical dBm W P...

Page 8: ...880 65 2 3311 62 2 1660 800 W 67 3 5370 64 3 2692 32 000 28 000 69 755 58 875 66 1 4074 63 1 2042 Heat Load Btu hr 8 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 8 Module...

Page 9: ...95 Heat Load Btu hr 8 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 8 Module RF Output Power AC Input Power W 7 Module Redundant RF Output Power Psat typical dBm W PLinea...

Page 10: ...7 68 5 7079 65 5 3548 800 W 70 0 10000 67 0 5012 64 000 56 000 139 511 117 751 69 4 8710 66 4 4365 Heat Load Btu hr 16 Module S Band PowerMAX System Power Specifications SSPA Module Power Level 16 Mod...

Page 11: ...Load Btu hr 16 Module Ku Band PowerMAX System Power Specifications SSPA Module Power Level 16 Module RF Output Power AC Input Power W 15 Module Redundant RF Output Power Psat typical dBm W PLinear mi...

Page 12: ...ar Parabolic Ripple 0 01 0 003 1 0 ns MHz ns MHz2 ns p p Noise Output TX Band RX Band C Band without filter RX Band X Band without filter RX Band X Band with filter RX Band Ku Band without filter RX B...

Page 13: ...1 592 13 76 25 1936 75 2RU FILLER 4RU FILLER 2RU FILLER 1RU PS2 1RU VENT 1RU PS1 1RU VENT 3RU SSPA 1 3RU SSPA 2 3RU SSPA 3 3RU SSPA 4 1RU RF DIST 3RU SSPA 5 3RU SSPA 6 3RU SSPA 7 3RU SSPA 8 3RU FILLER...

Page 14: ...WAY SYSTEM ONLY OMIT FOR 4 WAY 61 05 1550 8 59 18 1503 2 Cabinet Exhaust Option The PowerMAX system is available with an optional cabinet exhaust system which includes a rear door for the cabinet and...

Page 15: ...iginal form or after being incorporated into other items without first obtaining approval from the U S government or as otherwise authorized by U S law and regulations Proprietary and Confidential The...

Page 16: ...320 W 562 W 1000 W 100 S 638 W 1100 W 2000 W 200 S 970 W 1700 W 3000 W 300 S 1280 W 2240 W 4000 W 400 S 1600 W 2800 W 5000 W 500 S 2000 W 3500 W 6300 W 600 S 2500 W 4500 W 7800 W 800 S 3200 W 5600 W...

Reviews: