Teledyne Lecroy WaveSurfer 3000z Getting Started Manual Download Page 13

WaveSurfer 3000z Getting Started Guide

11

OVERVIEW

menu bar

 of drop-down menus lets you access set up dialogs and other 

functions. All functionality can be accessed through the menu bar.
The 

grid area

 displays the waveform traces. You can adjust the 

brightness of the grid lines to make other objects more visible.

Trigger level 

(vertical axis) and 

trigger time

 (horizontal axis) indicators 

appear on the grid when a trigger is set, color-coded to match the source.

Cursors

 show where measurement points have been set. Touch-and-drag 

cursor indicators to quickly reposition the measurement point. Vertical 

cursor readout appears on the Channel descriptor box; Horizontal cursor 

readout appears below the Timebase and Trigger descriptor boxes.
Channel (C1-C4), Zoom (Z1-Z4), Math (F1-F2), Memory (M1-M2), and 

Digital (Digital1-Digital2, with MSO option) 

trace descriptor boxes

 appear 

immediately below the grid and summarize current settings for each open 

trace. Touch the descriptor box to open the corresponding set up dialog.

Timebase and Trigger

 

descriptor boxes

 appear at the right of the display.  

Timebase and Trigger settings only apply to channel traces. Touch the 

descriptor box to open the corresponding set up dialog.

Dialogs

 appear at the bottom of the display for entering set up data. The 

top dialog will be the main entry point for the selected function.  
For convenience, related dialogs appear as a series of tabs behind the 

main dialog. Touch the tab to open the dialog

Apply measurement parameters to the trace

Display a zoom of the trace

Apply math functions to the trace

Copy the trace to internal memory  

(e.g., C2 to M2).

Scale the trace to fit the grid

Apply a custom label to the trace

The 

Action toolbar

 on the main Channel, Math, and Memory dialogs 

offers shortcuts to common actions so you don’t have to leave the 

underlying dialog. Actions always apply to the active (highlighted) trace.

Open serial data decoder dialogs  

(if options installed; else disabled)

Summary of Contents for WaveSurfer 3000z

Page 1: ...WaveSurfer 3000z Oscilloscopes Getting Started Guide...

Page 2: ...distribute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of...

Page 3: ...uals can be downloaded from the Oscilloscope Manuals page on our website at teledynelecroy com support techlib Introduction Introducing WaveSurfer 3000z Oscillosocopes 2 Key Specifications 2 Materials...

Page 4: ...tes the Most Advanced User Interface MAUI through a 10 1 capacitive touch screen It promotes true versatility with 20 Mpts of memory multi instrument capabilities a powerful deep toolbox and 100 MHz 1...

Page 5: ...nd use the built in carrying handle to move the instrument Use indoors only Keep product surfaces clean and dry Do not block the cooling vents Leave a minimum six inch 15 cm gap between the instrument...

Page 6: ...Touch Screen Display B Front Panel C Ground and Calibration Terminals D USB 2 0 Ports E Mixed Signal Interface F Channel Inputs G Rotating Tilting Feet H Power On Off Button Front of Oscilloscope OVER...

Page 7: ...ed for your country to the AC power inlet on the back of the instrument then plug it into a grounded AC power outlet see Power and Ground Connections in Safety The Power button controls the operationa...

Page 8: ...aveSource Output C Kensington Lock D Micro SD Card removable drive E EXT Trigger Input F AUX Output G VGA Video Output to external monitors H Ethernet Port I USBTMC Port for remote control J USB 2 0 P...

Page 9: ...ey Trigger Out To send a trigger pulse to another device connect a BNC cable from the AUX output on the back of the instrument to the other device LAN WaveSurfer 3000z is preset to accept DHCP network...

Page 10: ...t features two digital banks with separate threshold controls making it possible to simultaneously view data from different logic families Each flying lead has a signal and a ground connection A varie...

Page 11: ...o your Hardcopy settings e g print email or save to file or creates a Notebook Entry in LabNotebook if configured for it The Touch Screen button enables or disables touch screen functionality The Adju...

Page 12: ...play information also work as buttons to access other functions If you have a mouse installed you can click anywhere you can touch to activate a control in fact you can alternate between clicking and...

Page 13: ...below the grid and summarize current settings for each open trace Touch the descriptor box to open the corresponding set up dialog Timebase and Trigger descriptor boxes appear at the right of the dis...

Page 14: ...rtical precision is always maintained 256 Vertical Levels 256 Vertical Levels By default the oscilloscope has the Auto grid mode enabled Auto adds a new grid for each new type of trace analog channel...

Page 15: ...currently represented by the extreme Vertical and Horizontal margins of the grid When more data is available than can actually be displayed Trace Intensity helps to visualize significant events by ap...

Page 16: ...the grid area when a trace is turned on Descriptor boxes summarize and activate the traces they represent Inactive Controls will not work for this trace Active Controls will work for this trace Activ...

Page 17: ...you have a keyboard installed you can type entries in an active data entry field Or you can touch again then type the entry by touching keys on the virtual keypad or keyboard To use the virtual keypa...

Page 18: ...add positive or negative Offset The front panel Volts knob also controls the Vertical Scale of zoom math and memory traces Channel Descriptor Box Volts div Gain Offset Pre Processing Summary List cha...

Page 19: ...scriptor once to reactivate the trace twice to reopen the Cn dialog Refine Volts div or Offset Enter Attenuation for non Teledyne LeCroy probes Optionally change Vertical Unit of grid from Volts to Am...

Page 20: ...ive Digital line and bus traces Turn Offset to raise lower group Vertical Position the top of lowest bit relative to center Turn Volts to raise lower Group Height the total Vertical divisions occupied...

Page 21: ...c Family or enter a custom Threshold Separate controls allow you to set different values for each lead bank Choose a Display Mode of individual digital lines bus trace or both Optionally choose a new...

Page 22: ...you add positive or negative Delay time The front panel Time knob also controls the Horizontal Scale of zoom math and memory traces allowing you to zoom in to see more detail or zoom out to see the b...

Page 23: ...lt is the maximum available From the Touch Screen Touch the Timebase descriptor to open Timebase setup dialog Optionally enter Delay negative time before or positive time after trigger event to show S...

Page 24: ...id when trigger point is no longer visible Triggers Triggers tell the oscilloscope when to perform an acquisition The acquisition starts as soon as the trigger is armed and all trigger conditions are...

Page 25: ...escriptor to open Trigger setup dialog Choose trigger Type Choose trigger Source channel Set trigger Level or Find Level based on the input signal Set other conditions such as Slope and Coupling vary...

Page 26: ...visible BASICS From the Front Panel Create Zoom of all open traces The Zoom descriptor box shows the Zoom Source and Horizontal Scale which differs from the Timebase Adjust Horizontal Scale to change...

Page 27: ...p dialog touch Zoom Action Toolbar button to create a new zoom of just that source trace Zoom descriptor opens Zoom dialog to make other adjustments Draw a Zoom box over a portion of the source trace...

Page 28: ...perator s Manual All show the absolute value where the cursor intersects the waveform and the delta of the two lines From the Front Panel From the Touch Screen Cursors Cursor Setup opens the Cursor di...

Page 29: ...more traces and view the active readout in a table below the grid Statistics can be added to the readout along with histicons a miniature histogram of the statistical distribution You can also gate m...

Page 30: ...trace Fn tab to set up change function Math Math creates a new trace that displays the result of applying a mathematical function e g Sum Product FFT to one or more source traces Operations can be ch...

Page 31: ...pe is rebooted To store memories indefinitely save them to an external file by choosing File Save Waveform The file can then be recalled into one of the two internal memories for viewing by choosing F...

Page 32: ...eSurfer 3000z To use it just connect a BNC cable from the WaveSource output on the back of the oscilloscope to the input device and set up the waveform on the WaveSource dialog To access WaveSource Pr...

Page 33: ...ts and other user data files can be emailed directly from the instrument or saved to accessible network devices The oscilloscope can be added to a LAN via TCP IP or directly connected to a PC via USBT...

Page 34: ...mperature range the WaveSurfer 3000z will meet all specifications once warmed up Warm up the WaveSurfer 3000z for at least 20 minutes prior to each use so it can reach a stable operating temperature S...

Page 35: ...e USB Disk folder then select Upgrade 9 When installation is complete reboot the instrument CAUTION The installation may take several minutes depending on the length of time since your last update Do...

Page 36: ...in transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shipment Return of US...

Page 37: ...reases the task duration or difficulty of servicing the instrument Spare and replacement parts and repairs all have a 90 day warranty The instrument s firmware has been thoroughly tested and is presum...

Page 38: ...etic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shie...

Page 39: ...ecroy com patents Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The oscilloscope meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following sp...

Page 40: ...2018 Teledyne LeCroy Inc All rights reserved 929204 00 Rev A April 2018...