background image

Operator’s Manual 

Terms and Symbols 

The following symbols appear on the product or in its documentation: 

 

DANGER

 

High Voltage 

 

WARNING

 

Refer to Manual. Condition or practice 

could result in injury or loss of life. 

 

DOUBLE INSULATION

 

 

PROTECTIVE (EARTH) TERMINAL

 

Introduction 

The Teledyne LeCroy PP026 is a passive high impedance voltage 

oscilloscope probe designed and calibrated for use with general purpose 

oscilloscopes having an input impedance of 1 MΩ and can be compensated 

for use with instruments having an input capacitance between 10 to 20 pF.  

It is compatible with oscilloscopes that automatically detect probe 

attenuation and adjust their readout accordingly. 

Summary of Contents for PP026 Series

Page 1: ...PP026 1 PP026 2 Operator s Manual PP026 Passive Probe...

Page 2: ...roy is a registered trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earl...

Page 3: ...OTECTIVE EARTH TERMINAL Introduction The Teledyne LeCroy PP026 is a passive high impedance voltage oscilloscope probe designed and calibrated for use with general purpose oscilloscopes having an input...

Page 4: ...o 30 C 5 to 75 RH 30 C to 40 C 5 to 50 RH above 40 C RH not controlled below 10 C Operating Altitude 3000 meters maximum To reduce risk of fire or electric shock do not exceed the voltage or category...

Page 5: ...Operator s Manual 3 PP026 Input Impedance Profile Voltage vs Frequency Derating Curve...

Page 6: ...iance until 22 July 2017 per Article 4 Paragraph 3 General Safety Information Observe generally accepted safety procedures in addition to those listed here to avoid personal injury or damage to equipm...

Page 7: ...or cause other bodily injury if not handled properly Keep fingers behind the finger guard of probe body and accessories Do not operate with suspected failures Before each use inspect the probe and acc...

Page 8: ...n oscilloscopes Low Frequency 1 Apply a 1 kHz square wave to the probe or connect to the oscilloscope s calibrator output 2 Adjust the single LF trimmer located on the PP026 BNC Box until you achieve...

Page 9: ...compensated correct and under compensated waveforms Service Refer all service to qualified personnel For the most complete and up to date list of sales and service centers by country visit teledynele...

Page 10: ...PK5 PK6 002 Color Coding Rings 2 ea yellow red green blue 8 5 PK6 5MM 103 Ground Lead with Alligator Clip 1 6 PK6 5MM 104 Ground Spring 1 7 PK6 5MM 105 PCB Adapter 1 8 PK6 5MM 106 BNC Adapter 5mm 1 9...

Page 11: ...oy at its option will either repair or replace any assembly returned within the warranty period to the Customer Service Department of an authorized service center However this will be done only if the...

Page 12: ...925647 00 May 2015...

Reviews: