background image

Configuration and other Switch Settings

4

SW1: DUT Power Status LED on Interposer

This switch connects the DUT power Indication LEDs to the bus power. It is located near teh Lane Activity LEDS.

SW2: Clock Configuration Selection

The Host Type configuration used by the analyzer to record PCI Express traffic is configurable according to below table. DIP switches 
and tables for the Host Type configuration are located on the front side of the interposer.

SW3: NC-SI PHY Reset Pushbutton

SW4: Active Width Control Pushbutton

J8: Sideband Signal Header

Header 

Pin 

Number

Sideband 

Signal 

Name

Header 

Pin 

Number

Sideband 

Signal

 Name

Header 

Pin 

Number

Sideband 

Signal

 Name

Header 

Pin 

Number

Sideband 

Signal

 Name

1

BIF0#

6

PERST1#

11

PRSNTB0#

16

AUX_PWR_EN

2

SLOT_SMCLK

7

PERST0#

12

PRSNTB3#

17

NIC_PWR_GOOD

3

BIF1#

8

PERST3#

13

PRSNTA#

18

SMBRST#

4

SLOT_SMDAT

9

PERST2#

14

PRSNTB1#

19

PWRBRK0#

5

BIF2#

10

PRSNTB2#

15

MAIN_PWR_EN

20

WAKE#

SW1: DUT Power Status LEDs

ON

LED Connected (Default)

OFF

LED Disconnected

Note: 

This switch connects the DUT power indication LEDs to the bus power. In some systems with 

Hot-Plug management the Power Indication LEDs on the interposer may prevent the host system 
from turning ON bus power to the device, if this happens disconnect the LEDs using SW1 to allow 
proper bus power operation.

SW2: Clock Configuration

1

2

3

4

HOST  TYPE

ON

ON

ON

OFF

SINGLE HOST x16 (Default)

ON

ON

OFF

ON

DUAL HOST x8

ON

OFF

ON

ON

QUAD HOST x4

OFF

ON

ON

ON

N/A

Pushbutton reset switch SW3 is used for NC-SI RBT 
Interface PHY device reset.
Default position: Open

Pushbutton SW4 is used to turn off the terminations 
and remove all loads on the unused interposer 
receivers depending on the maximum number of 
lanes to be analyzed. Press the pushbutton switch 
(SW4) to move to the next active width as indicated 
by the LEDs (next to the switch) on the interposer. 
This is useful for devices that require terminations 
not to be present in order to train to a lower link 
width. The Active Width can be also controlled from 
the PCIe Protocol Analysis.
Default position: x16

Note: 

Even though the Active Width may be lower than 

x16, it may be possible that the Signal Detect LEDs for 
higher lanes are ON if those lanes are transmitting signal.

Summary of Contents for PCI Express Gen4 OCP NIC 3.0 Interposer

Page 1: ...rd used with the Summit T4 family of Protocol Analyzers enables PCIe bus traffic between a host backplane and Gen4 OCP NIC 3 0 form factor device to be monitored captured and recorded for protocol ana...

Page 2: ...ng options and start a recording For more information see the Summit T4 PCI Express Multi Lane Protocol Analyzer User Manual Gen4 OCP NIC 3 0 Interposer Configurations 9 Install the Interposer into th...

Page 3: ...connects the DUT power indication LEDs to the bus power In some systems with Hot Plug management the Power Indication LEDs on the interposer may prevent the host system from turning ON bus power to th...

Page 4: ...Test Point Name TP 1 3 3 V HOST TP 30 RBT_ARB_IN TP 40 LD TP 2 12V Host TP 31 12V FROM DC JACK TP 41 SLOT_ID1 TP 23 USBDATAP TP 32 SLOT_ID0 TP 42 DATA_OUT TP 24 USBDATAN TP 34 CLK TP 43 DATA_IN TP 27...

Page 5: ...mechanism Just slide the interposer in to the OCP slowly and the internal latch will lock in place No External latch bracket or Lever latch needs to be attached to the interposer See diagram below Ex...

Page 6: ...ee diagram below Lever Latch Installation If the server has been designed to use a Lever latch a Lever latch has been supplied with the Interposer and can be attached to the interposer as shown in the...

Page 7: ...ext to the PCB The Lever latch goes between the spacer and the bottom cover Then install the Phillips head screw through the hole in the bottom cover the hole in the Lever latch and then through the s...

Page 8: ...oduced without additional permission but all copies should contain this copyright notice Teledyne LeCroy Customer Support Online Download Periodically check the Teledyne LeCroy Protocol Solutions Grou...