923064-00 Rev A 

Safety Instructions 

This section contains instructions that must be observed to keep this oscilloscope accessory 
operating in a correct and safe condition. You are required to follow generally accepted 
safety procedures in addition to the precautions specified in this section. 

The overall safety 

of any system incorporating this accessory is the responsibility of the assembler of the 
system.  

Symbols 

These symbols may appear on the probe body or in this manual to alert you to important 
safety considerations.  

 

HIGH VOLTAGE

, risk of electric shock. 

 

CAUTION 

of potential for damage to probe or instrument it is connected to or 

WARNING

 

of potential bodily injury. Attend to the accompanying information to protect against 
personal injury or damage. Do not proceed until conditions are fully understood and met. 

 

ELECTROSTATIC DISCHARGE (ESD) HAZARD.

 The probe is susceptible to damage if anti-

static measures are not taken.

 

 

ON (POWER)

 

 

OFF (POWER) 

 

DOUBLE INSULATION

 

 

MEASUREMENT GROUND TERMINAL 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for AP031

Page 1: ...Operator s Manual AP031 Differential Probe www com information itm com 1 800 561 8187...

Page 2: ...90 days In exercising its warranty Teledyne Lecroy at its option will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized ser...

Page 3: ...mbols These symbols may appear on the probe body or in this manual to alert you to important safety considerations HIGH VOLTAGE risk of electric shock CAUTION of potential for damage to probe or instr...

Page 4: ...obe hooks to a votage source unless they are first connected to the probe input leads Ensure connections between probe input leads and probe hooks are secure before connecting them to a voltage source...

Page 5: ...relative to a floating voltage different to the oscilloscope ground potential This probe is specifically designed for situations where The reference voltage may be several hundreds volts above or bel...

Page 6: ...is calculated within the probe with only the resultant difference signal being passed to the oscilloscope a large dynamic range can be achieved with excellent rejection of common mode signals Figure 1...

Page 7: ...round Input Configuration Differential Input Voltage Max Differential 1 100 Range 700 V DC AC pk and 700 V r m s Max Differential 1 10 Range 70 V DC AC pk and 70 V r m s Max Common Mode 700 V DC AC pk...

Page 8: ...be expected General Characteristics Operating Temperature 10 C to 40 C Storage Temperature 30 C to 70 C Altitude Operating up to 2000 m 6560 ft Cable Length 1 3 m Weight probe only 42 g Power require...

Page 9: ...injury to the user from possible burns at higher frequencies WARNING To avoid risk of electric shock or fire do not exceed either the voltage rating or category rating of the probe or the probe hook w...

Page 10: ...oscilloscope channel to which the probe is connected using the Probe tab of the Channel Vertical setup dialog Ensure 1 M input impedance DC1M or AC1M is selected The use of 50 input impedance will un...

Page 11: ...e probes must be returned to a Teledyne LeCroy service facility for diagnosis and exchange A defective probe under warranty will be replaced with a factory refurbished probe A probe that is not under...

Page 12: ...Radiated and Conducted Emissions Group 1 Class A 1 2 Electromagnetic Immunity EN 61000 4 2 2001 Electrostatic Discharge 4 kV contact 8 kV air 4 kV vertical horizontal coupling planes 3 EN 61000 4 3 2...

Page 13: ...ions Act per the following standards in accordance with requirements imposed by Australian Communication and Media Authority ACMA CISPR 11 2003 Radiated and Conducted Emissions Group 1 Class A in acco...

Page 14: ...and laboratory use Part 2 030 Particular requirements for testing and measuring circuits EN 61010 031 A1 2008 Safety requirements for electrical equipment for measurement control and laboratory use Pa...

Page 15: ...disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper d...