15
Function Setting
Definition
Dual Motor
For 2 steps button model, only one relay active at a time i.e. press UP 1
st
step
button, the UP1S relay turns on. And press to 2
nd
step, the UP2S relay turns on
while UP1S relay turns off. There are 2 modes for Dual Motor as below
Dual Motors (1):
The 1
st
step relay is not active (bypass) when pushbutton is
released from 2
nd
step to neutral position.
Dual Motors (2)
: When pushbutton is released from 2
nd
step to neutral position.
The 1
st
step relay will turns on for very short time till the pushbutton is totally
released.
Acc. Delay
This function uses to set the time interval between acceleration relay (i.e.
conduction-delayed time of acceleration relay). It is suitable for accelerative
operation only in order to prevent the cranes directly runs to highest speed to
damage the motor.
EMS Control
Bypass EMS :
The relay will not be controlled by EMS button
Control by EMS: T
he relay is controlled by EMS button.
*Only available in Toggle, ON/OFF, ON/OFF/ON and Magnet mode.
Group Toogle
Relay motion acts as same as Toggle. The difference is when you press the
same button
twice
; the relay still remains ON until another Group Toggle button
is pressed. This Feature also can be programmed for different application to
setup a group of buttons to execute Toggle function.
Note:
“
Group Toggle
“
is available from group # 1~8
Interlock
The two pushbuttons are interlocked; it’s not possible to operate two opposite
functions at same time.
Normal Interlock A
The 2 opposite directional pushbuttons are interlocked. The two buttons could
not be turned on simultaneously.
Normal Interlock B
The two buttons could not be turned on simultaneously. In addition, the first
button turns ON will not be switch OFF if the relative button is being press. i.e.
UP and DOWN button preset in Normal Interlock(B),When UP relay turns ON,
press DOWN button then the UP relay remains ON without interruption.
Toggle Interlock
The two relays which set in Toggle Interlock mode could not be turn on
simultaneously. i.e. UP and DOWN relays are preset in toggle interlock. When UP
relay is ON, press DOWN button then the UP relay turns OFF while DOWN relay
turns ON.
Non-Interlock
The two pushbuttons can be operated at the same time: When the application
allows operating at the same time two functions which are usually opposite to
one another.