VS-600 Resident Unit Manual
B-11
Dial String part 4:
Notes what type of call device is making the call according to the
following chart:
Pendant:
1
Wireless Pull Cord:
2
Wired Pull Cord:
3
Sensor:
4
Call Cord:
5
Call Button:
6
Smoke Detector
7
Spare
8
Note:
The Resident Unit should only be used as an ancillary notification device for smoke detectors.
Ensure that the smoke detector is connected to a code-approved alarming device.
Dial String part 5:
Identifies a Page Zone will announce the call. In this example, Page Zone
10
.
Dial String part 6:
Identifies the station that the call-in will ring. In this example, station 580.
B.5.1
Default Dial String Table
The following table lists default primary and secondary dial strings for each type of call device.
Call Device
Primary Dial String
Secondary Dial String
Wall Unit Call
F,7256,1,6,10,580 F,7256,2,6,11,581
Call Cord
F,7256,1,5,10,580 F,7256,2,5,11,581
Wired Pullcord
F,7256,1,3,10,580 F,7256,2,3,11,581
Pendant F,7256,1,1,10,580 F,7256,2,1,11,581
Wireless Pull Cord
F,7256,1,2,10,580 F,7256,2,2,11,581
Sensor F,7256,1,4,10,580 F,7256,2,4,11,581
Smoke Detector
F,7256,1,7,10,580 F,7256,2,7,11,581
Spare F,7256,1,8,10,580 F,7256,2,8,11,581
Note:
The Resident Unit should only be used as an ancillary notification device for smoke detectors.
Ensure that the smoke detector is connected to a code-approved alarming device.