Audible Alarm Settings
An audible alarm is provided to indicate error conditions. This alarm can be deactivated by the
front panel ALARM ON/OFF-RESET switch. Refer to Figure 19 on page 22. In addition, the
REMOTE POWER and LOCAL POWER alarms can be disabled internally by SW6. Locate
SW6 in the upper right corner of the Main PC Board (Figure 8a on page 14).
Local Power Alarm
The LOCAL POWER ALARM indicates a failure in the external power input at this unit. To
configure the alarm for local power, configure SW6 according to Figure 14.
Figure 14: Alarm Switch — Local
Remote Power Alarm
The REMOTE POWER ALARM indicates a failure in the external power input at the remote unit
(i.e., the unit transmitting to this unit). To configure the alarm for remote power, configure SW6
according to Figure 15.
Figure 15: Alarm Switch — Remote
Alarms are latching. If an alarm occurs, the Audible alarm will sound until the front panel alarm
switch is set momentarily to OFF.