Model 458-3SLB (3-Slot Chassis)
Page 33
6. In order to ve
rify communication enter the command “id” and press the enter key. If data is
received back, then communication is successfully established.
NOTE:
The text “id” may not be displayed as seen in the above image if character echo is not
enabled on the 458 ch
assis. Enter the command “ee” (echo enable). For a short list of commands,
type the command “h” for help. For model specific commands, refer to the line module
documentation.
NOTE:
If multiple 458 chassis’ are on the local area network, a virtual Com port should be
configured and assigned to each device as described above. These devices can then be
controlled through HyperTerminal (or equivalent software) independently.
Using the Web Interface to Change Settings
The DeviceInstaller application provides a Web interface to select or change settings for the XPort.
To access the Web interface, do the following:
1. Launch the DeviceInstaller program. The DeviceInstaller control screen is displayed. Expand
the XPort device on the left side of the screen and click on the IP address for the device. The
right side of the screen changes to an interface with three tabs: Device Details, Web
Configuration and Telnet Configuration. Select the
Web Configuration
tab.