Model 458-3SLB (3-Slot Chassis)
Page 13
Responses to SC (SetCard) Command
*
Command valid and completed execution. Ready for
next command.
?[XXX] Card Not Found
Card not found in slot specified.
?[XXX] Invalid Card Number
Card number outside the range for the type of control
module.
?[XXX] Invalid Channel Number
Channel number out of range (e.g., not 1
– 8)
?[XXX] Invalid Length
Length not valid for the specific line module and/or
channel
?[XXX] Invalid Command
Any error not covered in the above list, including the
specification of incorrect line numbers for a given
channel.
Set all channels on all boards in the system command
:setcard:length:all:LE,C
Example: :setcard:length:all:2000,n sets all channels on all boards to 2000 ft.
Set all channels on a range of boards command
:setcard:length:LM-LM:LE,C
Example: :setcard:length:01-03:2000,n sets boards 1, 2 and 3 to 2000 ft.
Set all channels on one board command
:setcard:length:LM:a:LE,C
Example: :setcard:length:1:a:2000,n sets all channels on the board in slot 1 to 2000 ft.
Read Length command
:readcard:length:LM:H
Example: :readcard:length:01:1
Read the lengths of all channels on one board command
:readcard:length:LM:a
Example: :readcard:length:01:a