To avoid electric shocks, residual current circulation and other unwanted effects,
also affecting communications, the following is recommended:
•
It is highly recommended that all interconnected communication
devices are plugged to THE SAME GROUNDED POWER
OUTLET, which should at the same time be of good quality (lower
than 10ohms).
•
Whether the workplace is provided with an uninterrupted power
supply system (UPS), regulated supply or it is independent from the
rest (such as lighting, etc.); it is highly recommended that all data
devices should be connected to the same power source. This will
avoid operating and premature aging problems of drivers and other
components.
Connecting the ATLAS 160 and 260 power supply
Connecting the ATLAS 360 power supply
To connect the power source to the device, follow the steps listed in the earlier
table: ensure that the switch is OFF (0) and the power supply is NOT connected
to the main electricity supply; find the POWER plug, located on the rear panel of
the device and insert the power cable. Please use the grounded cable supplied
with the device for this purpose.
I - 2.2.
Connections
The
ATLAS X60
router has the following connectors available. Some of these
connectors may not be available depending on the model:
I - 2.2.1.
Interfaces GigaEthernet
GE 0, GE 1
:
GigaEthernet Interfaces. The
ATLAS X60
router has two connectors to
connect to Ethernet networks. Each interface has two connectors: one optic
connector (1000 LX SFP-LC) and one metal one (10/100/1000 Base-T).
The second LAN (GE 1) requires a software license in order to operate it.
ATLAS X60
Installation
I-4
Doc.
Dm695-I
Rev.
1.0