PABP USER MANUAL - PRELIMINARY 

Photoelectric Amplifier Bus Programmable Series (PABP)

 

 

Multiplexed photoelectric amplifier 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.27 Part Number: L40-0666220724 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

March 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

Page 5 of 5

 

 

 

tel 

EN 

All the settings for one channel can be copied to any other channel by selecting which module and channel the settings shall be copied too. 

 

 

 

 

 

 

 

 

Operation Modes 

 

Common Output

 

The 

Common Mode Output

 selector is used to obtain common or individual output from one or more amplifiers. If 

Common Mode Output

 is selected for the master and a number of slaves, the output 

of channel 1 on the master is activated if one or more channels among these amplifiers are activated. Furthermore LT/LR errors and insufficient signal level alarms are indicated on the master alarm 

output. The 

Common Mode Output

 is selected on all amplifiers channel 1. 

 

Grouping of modules

 

All modules with same group number are multiplexed within the group in sequence. If the modules are divided into two or more groups, by setting different group numbers for the modules, the various 

groups will be multiplexed in parallel.  This will reduce the cycle time for the multiplexing, but it must be ensured that the receivers of one group cannot see the transmitters of another group, in order to 

avoid interference. 

The Module Group is selected when setting channel 1 of the module. All modules are default set to group 0.   

 

 

 

PABP System Information 

 

The picture below shows the 

System Information

 window.  This window shows the PABP Bus address, which correspond to the rotary address selector. The Module type tells what type of PABP is at the 

given bus address. The production year and month are also listed for each module. 

 

 

 

Adjustments 

 

Factory Reset

 

It is possible to reset one or several modules channels to the factory settings. To do so select one or several modules and press the 

Factory Reset

 button. 

 