PABP USER MANUAL - PRELIMINARY
Photoelectric Amplifier Bus Programmable Series (PABP)
Multiplexed photoelectric amplifier
Website: www.telcosensors.com
Warning
V 1.27 Part Number: L40-0666220724
E-Mail: [email protected]
This device is not to be used for Personnel Protection in Machine
Guarding Safety applications. This device does not include the self-
checking redundant circuitry necessary to allow its use in personnel
machine guarding stand-alone safety applications.
March 2019 edition
Made in Denmark
Telco A/S reserves the right to make changes without prior notice
Page 5 of 5
tel
EN
All the settings for one channel can be copied to any other channel by selecting which module and channel the settings shall be copied too.
Operation Modes
Common Output
The
Common Mode Output
selector is used to obtain common or individual output from one or more amplifiers. If
Common Mode Output
is selected for the master and a number of slaves, the output
of channel 1 on the master is activated if one or more channels among these amplifiers are activated. Furthermore LT/LR errors and insufficient signal level alarms are indicated on the master alarm
output. The
Common Mode Output
is selected on all amplifiers channel 1.
Grouping of modules
All modules with same group number are multiplexed within the group in sequence. If the modules are divided into two or more groups, by setting different group numbers for the modules, the various
groups will be multiplexed in parallel. This will reduce the cycle time for the multiplexing, but it must be ensured that the receivers of one group cannot see the transmitters of another group, in order to
avoid interference.
The Module Group is selected when setting channel 1 of the module. All modules are default set to group 0.
PABP System Information
The picture below shows the
System Information
window. This window shows the PABP Bus address, which correspond to the rotary address selector. The Module type tells what type of PABP is at the
given bus address. The production year and month are also listed for each module.
Adjustments
Factory Reset
It is possible to reset one or several modules channels to the factory settings. To do so select one or several modules and press the
Factory Reset
button.
!