PABP USER MANUAL - PRELIMINARY 

Photoelectric Amplifier Bus Programmable Series (PABP)

 

 

Multiplexed photoelectric amplifier 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.27 Part Number: L40-0666220724 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

March 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

Page 4 of 5

 

 

 

tel 

EN 

 

 

Adjustments 

 

Manual Gain Mode Adjustment                                                                              

 

Gain can be adjusted in two large steps with long/ short range selected or continuously with the 

Manual Gain 

bar. Maximum gain and long range can be used for most applications and is advised for 

applications with contaminated environments e.g. dirt, water and dust. 

Chose long range and increase the gain to maximum by sliding the 

Manual Gain 

bar to a 100% reading. 

More accurate sensitivity adjustment may be required in applications where objects to be detected are small or translucent. Proceed with the following steps: 

Make sure there is no object present between remote transmitter and receiver sensors. 

Select long or short range according to application. 

Increase gain slowly from minimum (0%) until the yellow output indicator changes. Increase a little further until the green Signal OK indicator is on. 

Select target object with smallest dimensions and most translucent surface. 

Place target object between remote transmitter and receiver sensors. If the output changes, the gain is adjusted correct. If the output does not change proceed to step 6. 

 

Remove the object and decrease the gain by sliding the “Manual Gain Bar” towards 0% until the green Signal OK indicator is off  and the LT/LR error indicator flashes simultaneously  with red 

and yellow light 

 

 

Place target object between remote transmitter and receiver sensors. If the output changes, the gain is adjusted to suit the target but the adjustment is very delicate and not advisable, please 

contact your vendor for further information. 

 

 

If the signal level is insufficient, the LT/LR error indicator flashes simultaneously with red and yellow light. Check the following: 
Check alignment of sensors 
Check transmitter and receiver sensors are within sensing range 
Check gain adjustment 
Check sensor heads are not excessively contaminated 

 

Auto Gain Mode Adjustment                                                                               

 

This amplifier automatically compensates for reduction in transmission power due to dirt on sensors, etc, by increasing the transmission power correspondingly. Adjust excess gain with the following 

steps: 

Make sure there is no object present in the beam between remote transmitter and receiver sensors. 

Turn the slider 

Excess Gain

 bar to 3.2 (max excess gain) 

Wait for regulation indicator to stop blinking, and initialization is finished.  

If this never happens, the reason can be that the environment or the sensors are too contaminated, the distance between transmitter and receiver is too large, or the sensors are misaligned. 

Insert the smallest and most translucent object into the beam. 

If the output changes, the setting is correct. 

 If the output does not change, proceed with step 5. 

Remove the object, decrease excess gain slightly by sliding the 

Excess Gain

 bar towards 1.5 (lowest excess gain).  

If more adjustments have been done and it is not possible to decrease excess gain further, the object cannot be detected with the given setup. Please contact the vendor for further advice.  

Wait for the regulation indicator to stop blinking (finished new initialization). 

Go to step 4  

 

Alarm Level Setting

 

It is possible to manually adjust two alarm levels. 

Alarm(SW)

 and 

Alarm(HW) l

evels. These are in direct relation to the 

Signal Level

 bar so when adjusting the alarm levels means that when the signal 

is below that value the alarm is triggered and displayed on the 

Online Overview

 and 

Device Setup

. The 

Alarm(SW)

 is only triggered in the 

PABP Terminal Software

 whereas the

 Alarm(HW)

 is 

directly related to the Alarm Output pin of the specific PBAP module. If a slave and master are in modules is in common mode a 

Alarm(HW)  

will be transferred to the master module Alarm output pin as 

well. It is not possible to adjust the alarm levels in Auto Gain mode, as the only alarm associated with Auto gain is the 

Hardware Alarm

. This is only triggered when it is not possible to obtain the wanted 

excess level. 

 

Hysteresis Level Setting

 

It is possible to manually adjust the hysteresis level of each channel. The range goes from a maximum hysteresis of approx. 35% to no hysteresis of 0%. The hysteresis is related to the maximum 

sensing range.  

 

Turning Off a Channel

 

It is possible to turn off the PABPs channels. This is done by unchecking the 

Channel Activate

 checkbox. The channel will then be completely ignored by the PABP. If the channel has the Output set 

into a Forced output state, this forced state will be still kept and the channel output forced into that state when the channel is turned off. 

 

Delay Level Setting

 

The 

On Delay

 enables output signal to only activate if an object in the detection area is present for the adjusted time period. The 

Off delay

 enables output signal to remain activated for the adjusted time 

period. The time delay is adjustable between 0-10 s.  

 

Diagnostic Control

 

Besides the hardware test input which disables the transmitter for all channels on the amplifier, is it also possible to use a test input for each channel on the amplifier. The outputs can also be controlled 

individually to be ON or OFF. Doing this will ignore that channel and the rest is still multiplexed. This is all controlled from the 

Diagnostic Control

 window.  Shown in the next picture. 

Check the 

Diagnostic Control On

 checkbox. The program will come up with a warning textbox and all other controls will be disabled. 

Either use 

Test Input

, which will test a complete transmitter – receiver chain. This is done by 

Transmitter Diagnostics

, with no objects in the beam.  

Or 

Enable Forced Output

 to manually force the outputs On or OFF. Forced output allows the user to test the outputs even if the beam is blocked. 

To return to normal mode uncheck the 

Diagnostic Control On

 checkbox. 

 

Factory Reset

 

Each channel can be reset to the factory settings by pressing the 

Reset

 on the 

PABP Device Setup

 page. 

 

Copy Setting To

 