PABP USER MANUAL - PRELIMINARY 

Photoelectric Amplifier Bus Programmable Series (PABP)

 

 

Multiplexed photoelectric amplifier 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.27 Part Number: L40-0666220724 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

March 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

Page 1 of 5

 

 

 

tel 

EN 

Product Data 

 

Electrical Data 

Supply voltage 

10-30 V dc / 24V ac 

Power consumption 

Max. 3.6 VA 

Output: solid state 

30 V dc / 100 mA 

Alarm output: solid state 

30 V dc / 100 mA 

 

Environmental Data 

Temperature, operation 

-10 to +50 °C 

Sealing class 

IP 40 

Approvals 

 

 

 

Applicable Remote Sensors & Sensing Ranges for Manual Gain mode

 

Remote Sensor Series 

Sensing Range 

100 

12 m 

110 

27 m 

120 

47 m 

Comments:  

The range is reduced to 30 % in short range mode.  

 

Applicable Remote Sensors & Sensing Ranges for Auto Gain mode

 

Remote Sensor Series 

Sensing range 

Short range 

Long range 

100 

0.4 m – 4 m 

1 m – 10 m 

110 

0.9 m – 9 m 

2.2 m – 22 m 

120 

1.6 m – 16 m 

3.9 m – 39 m 

 

Illustration 

 

 

 

              PABP xx M 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

              PABP xx S 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicators 

Power On  

Green light when power is on 

Master Status Indicator 

Green light when amplifier is working as master 
Green flashing light if amplifier is master and in error state 

Slave Status Indicator 

Orange light when amplifier is slave 
Orange flashing light if amplifier is slave and in error state 

Signal OK / Regulation 

Indicator 

Green light when signal is sufficient and beam is unbroken 

Only Auto Gain Mode:

 Green light when signal beam is un-

broken and still room for increasing transmission power.  

Green light is flashing during adjustment excess gain. 

Output 

Yellow light when output is activated  

LT/LR error 

Red light for transmitter error (disconnection or shorted) 
Yellow light for receiver error (disconnection or shorted) 
Yellow and red light flashes for insufficient signal level (for 

instance caused by contamination on sensors) 

Only Auto Gain Mode: 

Yellow and red light flashes if target 

excess gain is not obtained and transmission power is maximum 

 

Selectors 

Slave address selector 

Select addresses 1,...,10 to set the amplifier address. Each of 

the slaves must have a separate address in sequence starting 

from 1. 

 

Connection

 

 

Wiring Diagrams

 

PABP 10 – 1 Channel 

PABP 20 – 2 Channel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PABP 30 – 3 Channels 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

 All outputs and alarm output are N.O. when the system is not powered. 

 

RJ 45 wiring 

 

 

 

 

 

 

 

 

Pin on RJ45 

MODBUS IDv/Itr 

EIA/TIA RS 485 

Description 

D1 

B/B’ or B + 

Signal 

DO 

A/A’ or A - 

Signal 

Common 

C/C’  

Ground 

 

* Note:

 Baud rate selector is disabled for this series. Baud rate is set to 19200 bps for optimum functionality. 