PABP USER MANUAL - PRELIMINARY
Photoelectric Amplifier Bus Programmable Series (PABP)
Multiplexed photoelectric amplifier
Website: www.telcosensors.com
Warning
V 1.27 Part Number: L40-0666220724
E-Mail: [email protected]
This device is not to be used for Personnel Protection in Machine
Guarding Safety applications. This device does not include the self-
checking redundant circuitry necessary to allow its use in personnel
machine guarding stand-alone safety applications.
March 2019 edition
Made in Denmark
Telco A/S reserves the right to make changes without prior notice
Page 1 of 5
tel
EN
Product Data
Electrical Data
Supply voltage
10-30 V dc / 24V ac
Power consumption
Max. 3.6 VA
Output: solid state
30 V dc / 100 mA
Alarm output: solid state
30 V dc / 100 mA
Environmental Data
Temperature, operation
-10 to +50 °C
Sealing class
IP 40
Approvals
Applicable Remote Sensors & Sensing Ranges for Manual Gain mode
Remote Sensor Series
Sensing Range
100
12 m
110
27 m
120
47 m
Comments:
The range is reduced to 30 % in short range mode.
Applicable Remote Sensors & Sensing Ranges for Auto Gain mode
Remote Sensor Series
Sensing range
Short range
Long range
100
0.4 m – 4 m
1 m – 10 m
110
0.9 m – 9 m
2.2 m – 22 m
120
1.6 m – 16 m
3.9 m – 39 m
Illustration
PABP xx M
PABP xx S
Indicators
Power On
Green light when power is on
Master Status Indicator
Green light when amplifier is working as master
Green flashing light if amplifier is master and in error state
Slave Status Indicator
Orange light when amplifier is slave
Orange flashing light if amplifier is slave and in error state
Signal OK / Regulation
Indicator
Green light when signal is sufficient and beam is unbroken
Only Auto Gain Mode:
Green light when signal beam is un-
broken and still room for increasing transmission power.
Green light is flashing during adjustment excess gain.
Output
Yellow light when output is activated
LT/LR error
Red light for transmitter error (disconnection or shorted)
Yellow light for receiver error (disconnection or shorted)
Yellow and red light flashes for insufficient signal level (for
instance caused by contamination on sensors)
Only Auto Gain Mode:
Yellow and red light flashes if target
excess gain is not obtained and transmission power is maximum
Selectors
Slave address selector
Select addresses 1,...,10 to set the amplifier address. Each of
the slaves must have a separate address in sequence starting
from 1.
Connection
Wiring Diagrams
PABP 10 – 1 Channel
PABP 20 – 2 Channel
PABP 30 – 3 Channels
Note:
All outputs and alarm output are N.O. when the system is not powered.
RJ 45 wiring
Pin on RJ45
MODBUS IDv/Itr
EIA/TIA RS 485
Description
4
D1
B/B’ or B +
Signal
5
DO
A/A’ or A -
Signal
8
Common
C/C’
Ground
* Note:
Baud rate selector is disabled for this series. Baud rate is set to 19200 bps for optimum functionality.
!