1
5
4
1
4.2.3 Power supply cable
To set up the power supply for the air conditioner,
lay a three-pole (positive-neutral-earth), power sup-
ply cable with a cross section of at least 2.5 mm
2
.
This cable must be connected at one end to the
differential cut-off switch previously placed inside
the distribution board of the vehicle, while the other
end must reach the opening on the roof. Let the
cable come out from the reinforcing frame by about
50 cm to allow easier connection to the air condi-
tioner [Fig. 6].
6
Before performing any kind of
connection, always make sure that there is no
power inside the distribution board or at the
cable end.
The air conditioner must be powered from a sepa-
rate cable, which must be provided with a 10A fuse.
The cable must be sheathed so
it can provide proper insulation under any con-
dition of use of the vehicle.