background image

Summary of Contents for TM 501

Page 1: ...ktronix Inc P O Box 500 Beaverton Oregon 070 1304 01 Product Group 75 Tektronix COMMTTTHITO EXCCULENCE TM 501 POWER MODULE INSTRUCTION MANUAL 97077 Serial Number First Printing MAY 1972 Revised JUN 19...

Page 2: ...ved INSTRUMENT SERIAL NUMBERS Each instrument has a serial number on a panel insert tag or stamped on the chassis The first number or letter designates the country of manufacture The last five digits...

Page 3: ...TIONS General 2 1 Building a System 2 1 Installation and Pre Turn On Procedure 2 3 Section 3 MAINTENANCE General 3 1 Troubleshooting Aids 3 1 Troubleshooting Techniques 3 2 Parts Ordering and Replacin...

Page 4: ...acle b ore connecting to the product input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe opera tion Danger Arising From L...

Page 5: ...ages exist at several points in this product To avoid personal injury do not touch exposed connec tions and components white power is on Disconnect power before removing protective panels soldering or...

Page 6: ...ignitf...

Page 7: ...nstru ment is operated at an ambient temperature between O C and 50 C Table 1 1 ELECTRICAL CHARACTERISTICS 1 Characteristics Performance Requirements Supplemental Information SUPPLIES 33 5 Vdc Toleran...

Page 8: ...Vdc 7 5 A 3 AG fast blow SERIES PASS TRANSISTORS Type One each NPN or PNP Maximum dissipation 7 5 W each 15 W total SOURCE POWER REQUIREMENTS Voltage ranges Selectable 100 V 110 V 120 V 200 V 220 V an...

Page 9: ...km 15 000 H Non operating 15 km 50 000 ft Vibration 0 26 mm 0 010 10 Hz to 55 Hz 75 minutes Shock 20 g s 1 2 sine 11 ms 18 shocks Bench handling 45 4 or equilibrium whichever occurs first Transportati...

Page 10: ...e applying power Module Installation Turn fhe Power Module off before inserting the plug in otherwise damage may occur to the plug in circuitry 1 Check the location of the white plastic barrier keys o...

Page 11: ...assignments of each pin at the rear interface Once having made interconnections ot a specialized nature it is recommended that barriers be Installed on the interconnecting jacks to ensure module compa...

Page 12: ...heck the rear panel markings If the factory settings are compatible with the available line voltage and frequen cy insert the desired plug ins If a change is needed refer a qualified service person to...

Page 13: ...he Instruction Manual for each unit for complete calibration and verification procedures TROUBLESHOOTING AIDS Introduction The following is provided to augment Information contained elsewhere in this...

Page 14: ...nts etc Power Cord Conductor Identification Alternate Color Black White Green Yellow Testirtg Equipment Instrument Calibration Check the calibration of the suspected plug in module or the affected cir...

Page 15: ...de may be checked for an open or shorted condition by measuring the resistance between terminals With an ohmmeter scale having an internal source of between 800 mV and 3 V the resistance should be ver...

Page 16: ...ument that may be affected Replacement semiconductors should be of the original type or a direct replacement Figure 3 1 shows the lead configurations of the semiconductors used in this instru ment sys...

Page 17: ...antistatic suction type or wicK type desoldering tools Test Equipment Before using any test equipment to make measurements on static sensitive components or assemblies be certainthat any voltage or c...

Page 18: ...For assistance contact your local Tektronix Field Office or representative NOTE A cam type switch repair kit including necessary tools instructions and replacement contacts is available from Tektronix...

Page 19: ...ity as possible In stead prepared jumpers coax cables arx interconnection jack barriers are included in the TM 501 System Design Directions 1 Plan the plug in location based on the front panel control...

Page 20: ...length then tin andsoldertheend going tothe rear panel Packaging Information A list of standard accessories and part numbers is located m the Replaceable Mechanical Parts list If the Tektronix instru...

Page 21: ...tage and Table 3 2 determine if a change is necessary Position 120 Volts Nominal Fig 3 S Primary laps locations Table 3 2 shows which position the selector block should be m for specific line voltages...

Page 22: ...Maintenance TM S01 Rg 3 6 Record line voltage Mtling 1304 07 3 10 JUL 1980...

Page 23: ...4 TM 501 OPTIONS Option 2 Information about this option may be found in the following sections Section 2 Operating Instructions Section 3 Maintenance Section 7 Replaceable Mechanical Parts REV OCT 19...

Page 24: ...contact you concerning any change in part number Change information if any Is located at the rear ol this manual SPECIAL NOTES AND SYMBOLS XOOO Part first added at this serial number OOX Part removed...

Page 25: ...ROUP 5005 E HCOONELL RO PHOENIX AZ 85008 14099 SEMTECH CORP 652 MITCHELL ROOD NENBURY PORK CA 91320 19701 NEPCO ELECTRA INC A NORTH AMERICAN PHILIPS CO P 0 BOX 760 MINERAL HELLS TX 76067 31781 EOAC IN...

Page 26: ...1N5624 D1C030 152 0198 02 8040000 SEMICONO DVC 0I BECT SI 200V 30 02490 14099 SS4986 01CB32 152 0198 00 8010100 8039999 SEMICONO DVC D 0ECT S1 200V 30 0249 03508 1N5624 01CS32 152 0198 02 8040000 SEM...

Page 27: ...ookup table for the schematic diagram and corresponding component locator illustration The Replaceable Electrical Parts list is arranged by assemblies in numerical sequence the components are listed b...

Page 28: ...PARTS LOCATION GRID...

Page 29: ......

Page 30: ...mmon return 11 5 V filtered DC 25 VAC winding FRONT VIEW A B 28 28 27 27 26 26 25 25 24 24 23 23 22 22 21 21 20 20 19 19 18 18 17 17 16 16 IS IS 14 14 13 13 12 12 11 11 10 10 9 9 8 6 7 7 6 6 5 fT 4 4...

Page 31: ...al side of the line PI it wired to place the primary windings in parallel for nominal 120V line voltage operation P2 is wired to place the primary windings in series for nominal 220 V line voltaga iqs...

Page 32: ...s must be purchased separately untess otherwise eclfied ITEM NAME In the Parts List an Item Name Is separated from the description by a colon Because of space limitations an Item Name may sometimes ap...

Page 33: ...70903 0EUIEN CORP 2000 S BOTOVIO OVE GENEVA IL 60134 71460 m CANNON ELECTRIC OIV INTERNOTIONOL TELEPHONE UNO TELE6R0PH CO 666 E OYER RO SANTA ONO CO 92702 73743 FISCHER SPECIOL NR CO 446 MWGON ST CIN...

Page 34: ...6 07 8082890 1 GUIOE PL IN UNI U NEB NYU N BTTOCHING POSTS 80009 351 0288 07 16 211 0101 00 8010100 8082889 1 SCSD4 N0CH NE 4 40 X 0 2S0 FIH 100 OG STL 83385 OSOEB BY OESCB 213 0814 00 8002890 1 SCBEN...

Page 35: ...62S STEEL 80009 200 0379 01 200 0379 05 8094540 1 COVER ELEC XFNfi 2 S X 3 0 X 0 625 STEEL 80009 200 0379 05 334 2990 00 8094540 1 MARKER I0EKT HK0 CAUTION 80009 334 2990 00 43 210 0201 00 1 TERHINAL...

Page 36: ...01 HONUOL TEDCINSTB 80009 070 1304 01 OPTION 02 1 131 1345 00 2 131 1319 00 3 195 0993 00 4 175 3301 00 5 214 1593 02 1 C0M4 RCPT ELEC D SERIES SO CONT FEMLE 1 SMID ELEC COW 6 LEA0 EIECT9ICAL 22 ONG...

Page 37: ......

Page 38: ......