THM500 Series Specifications
Bench Test Instruments and Handheld Oscilloscopes Basic Service
7
Table 3: Scope specifications (cont.)
565
560
550
Waveform display
Display Update Rate
Dynamic Display Digital Signal Processing maps up to 750 waveforms/s on
screen, simulating an analog-like display.
D
D
D
Memories
Setups
Each setup memory stores the complete state of the instrument, including the
multimeter state.
4
4
8
Waveforms
Each waveform memory stores all waveform points and the scale of the selected
waveform.
4
4
8
Screens
Each screen memory stores the exact information displayed on screen
(snapshot).
1
1
8
Table 4: General specifications
550 560 565
Clock
D
Real Time
Provides date and time stamp capability for line test events and saved
waveforms.
D
D
D
Display system
Display Type
Super Twisted Liquid Crystal Display
D
D
D
Size
Width: 120 mm (4.72 inch)
Height: 60 mm (2.36 inch)
D
D
D
Display Resolution
256 pixels horizontal
×
128 pixels vertical
D
D
D
Contrast
User adjustable
D
D
D
Backlight
Electroluminescent
D
Waveform Graticule
8 divisions vertical
×
10 divisions horizontal
Default = crosshair, grid, or none
1 vertical division = 15 pixels
1 horizontal division = 25 pixels
D
D
D
Power source
Batteries
Six AA cells (9 V nominal)
D
D
D
Battery Life (Typical)
4.5 hours continuous operation with alkaline cells (backlight off). Tested using
RAYOVAC
R
Alkaline MAXIMUM
T
batteries. Battery life extended when used
intermittently.
D
D
D
Battery Saver
User adjusted battery saver feature turns the instrument off after five minutes
and the backlight off after one minute.
D
D
D
Memory Retention Time
Memory hold-up time following battery removal: eight minutes minimum, three
hours typical. Memory retention extended (weeks or months) if discharged
batteries remain installed.