Select a 1/2 inch spaced hole in the front rail.

2.

Select the mounting method according to your rack type:

H

To mount the slide-out tracks with their front and rear flanges outside of
the front and rear rails, use method A shown in Figure 3 when doing
step 3. Add a bar nut to the installation only if the rails have untapped
holes.

H

To mount with front and rear flanges inside of rack rails, use mounting
method B shown in Figure 3. This mounting method assumes untapped
holes.

3.

Using the method and hardware determined from step 2, secure the right
slide-out track assembly to the equipment rack front and rear rails. The
screws should be fully, but lightly, seated so that you can adjust the rack
later.

4.

Tighten the screws, applying 28 inch-lbs of torque, left loose in step 4 in

Assembling the Slide-out Tracks

on page 7 to fix the front to rear flange

spacing of the slide-out track assembly.

5.

Repeat steps 1 through 4 to mount the left slide-out track assembly.

Left slide-out track

Right slide-out track

Use a bar nut if front
rails are not tapped

Left slide-out track
assembly

10-32 Panhead

screw

10-32 Panhead

screw

10-32 Flat head

screw

Use flat head screws if the cabinet rails have
countersunk mounting holes; otherwise use
panhead screws

Left-front rail

Mounting Method A

Mounting Method B

Figure 3: Installation of slide-out track assemblies in rack (top view)

Mounting the Slide-out

Tracks

Summary of Contents for SPG600

Page 1: ...01 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety summaries pri...

Page 2: ...nd pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektr...

Page 3: ...of this product unless another person capable of rendering first aid and resuscitation is present Disconnect Power To avoid electric shock disconnect the mains power by means of the power cord or if p...

Page 4: ...Service Safety Summary ii SPG600 Sync Pulse Generator Rackmount Instructions...

Page 5: ...ts Tektronix modifications ECR31439 and ECR31689 Products SPG600 All serial numbers Kit Parts List Figure 1 on page 2 Quantity Part number Description 1 1 1 ea 351 0104 xx Guide rack consisting of lef...

Page 6: ...Kit Description 2 SPG600 Sync Pulse Generator Rackmount Instructions 1 2 3 3 1 Figure 1 Rackmount kit parts...

Page 7: ...Rackmount Instructions 3 439 4 mm 17 3 in 425 4 mm 16 7 in 514 5 mm 17 3 in 544 5 mm 21 4 in 15 4 mm 0 6 in 13 0 mm 0 5 in 115 7 mm 4 6 in 320 7 mm 12 6 in 43 6 mm 1 7 in 482 5 mm 19 0 in Figure 2 SPG...

Page 8: ...Kit Description 4 SPG600 Sync Pulse Generator Rackmount Instructions...

Page 9: ...and equipment Description Screwdriver handle magnetic Accepts 1 4 inch hex head driver tips 2 Phillips tip Philllips driver tip for M3 size screw heads 2 Pozidriv tip Pozidriv driver tip for 2 size s...

Page 10: ...inside track to the four mounting holes on the right side of the instrument 3 Using a screw driver with a 2 Phillips tip install the right inside track to the right side of the instrument using four...

Page 11: ...en the front and rear rail of the equipment rack 3 Align the rear bracket to the right slide out track as shown in Figure 2 Note that the rear bracket has multiple pairs of mount through holes When al...

Page 12: ...ions 10 32 Panhead screw Flat bar nut use if front rail is not tapped Front rack 10 32 Panhead screws Flat bar nut Rear rack Stop latch hole Inner track Outer track Flat bar nut Rear bracket Stop latc...

Page 13: ...track assembly to the equipment rack front and rear rails The screws should be fully but lightly seated so that you can adjust the rack later 4 Tighten the screws applying 28 inch lbs of torque left l...

Page 14: ...d step 3 in Mounting the Slide out Tracks on page 9 and then pull the instrument part way out of the rack 6 Be sure the two screws that were left loose at the front of the rack are loose enough to all...

Reviews: