2-9
Installation
Model 4000-3 Control Panel Installation
A full flush-mount installation requires countersunk edges. The Panel enclosures
(upper and lower tubs) slip into the cutout from the top, are fitted into the routed
openings, and secured by 27 screws inserted through overhanging flanges at the
front, rear, and sides of the tubs.
NOTE:
The lower Control Panel tub should be installed on as flat a surface as possible. It
is not recommended to have more than a 10° tilt, as this would add excessive weight on the
gas shocks supporting the lower panel lid.
To guarantee adequate cable clearances leave a minimum of 11.5” (29.0 cm) of clear space
inside the console behind the upper Control Panel, and 3.25” (8.3 cm) of clear space inside
the console behind the lower Control Panel for control, signal, and power cables and
connectors. See
If you elect to reduce these minimums, we
suggest the Control Panels be on site before you prepare the console.
0347-02-23
5.00"
(12.7 cm)
3.25"
(8.3 cm)
11.5"
(29.2 cm)
5.469"
(13.9 cm)
5.0"
(12.7 cm)
Figure 2-5. Model 4000-3 Control Panel Cable Clearance